Abstract
In this study, nanofiltration (NF) was used to further treat the water from the disinfection process of a drinking water treatment plant (DWTP). The results indicate that the NF process reduced the dissolved organic carbon (DOC) by 92.87%, UV absorbance at 254 nm (UVA254) by 88.68%, conductivity by 94% and total dissolved solids by 94.49%. The removal efficiencies of trihalomethanes (THMs), 2-methylisoborneol (2-MIB) and trans-1,10-dimethyl-trans-9-decalol (geosmin) were also evaluated for both the DWTP and NF treatment processes. High-performance size-exclusion chromatography (HPSEC) analysis, three-dimensional excitation–emission matrix (3D-EEM) fluorescence spectroscopy and parallel factor (PARAFAC) analysis were applied to characterize the changes in different organic compounds in each process. A correlation analysis was carried out for samples of the raw water, feed water and permeate water to determine the correlations between the maximum fluorescence intensities (Fmax) of the PARAFAC components and the DOC, UVA254 and high specific UV absorbance (SUVA) of the samples. The results showed that a significant correlation (p < 0.01) existed between UVA254 and the Fmax of the three PARAFAC components as well as between DOC and Fmax.
INTRODUCTION
The life quality of the Chinese people has been improved significantly in the past few decades, and this can be related to the improvement in their drinking water quality. Drinking water is one of the essential substances in daily life; thus, its quality continues to gain increasing attention. At present the drinking water treatment plants (DWTPs) in China are usually made up by the coagulation–sedimentation–rapid sand filtration–disinfection process. However, such technologies result in poor removal efficiency for typical organic matter such as taste and odour compounds (T&O) (Bruce et al. 2002), disinfection by-product precursors (DBPs) (Zheng et al. 2018), antibiotics and endocrine disruptors (Chen et al. 2013). Thus, the above water treatment process cannot fulfil the increased stringency of drinking water regulations and further improve the quality of drinking water. The most common T&O compounds are nontoxic, but they affect the taste of drinking water even at extremely low concentrations (Srinivasan & Sorial 2011). Meanwhile, the DBPs formed during the chlorination procedures of drinking water can greatly harm human health (Nazir & Khan 2006), and the presence of antibiotics and endocrine disruptors in the water also poses a severe risk to the human endocrine system (Snyder 2008; Mo et al. 2017). Therefore, researching and exploring more efficient drinking water treatment technologies to provide people with healthier and more sanitary drinking water is one of the main research goals at present.
Many studies have shown that including an ozone bioactive-carbon (O3-BAC) process after the rapid sand filtration can effectively improve the drinking water quality (Yang et al. 2015). Using O3-BAC treatment, Liao et al. (2013) significantly improved the reduction of CODMn, UV absorbance at 254 nm (UVA254) and dissolved organic carbon (DOC) in water by approximately 31%, 43.3% and 45.5%, respectively. Faruqi et al. (2018) and Chen et al. (2019) also employed O3-BAC to remove 2-methylisoborneol (2-MIB) and geosmin occurring in water. The advanced treatment also has a significant removal effect on the DBPs in drinking water (Liao et al. 2019). However, the actual application of the O3-BAC process also features some disadvantages: the problem of microorganism leak in the BAC filter affects the water quality (Lu et al. 2011). When higher concentrations of bromide are present in the water, the formation of bromate from bromide (Br−) oxidation during the ozonation process will introduce unwanted substances into the drinking water (Yang et al. 2015). The activated carbon adsorbent can become saturated, decreasing the treatment effect. In a previous study, compared with the new BAC filter, the old BAC filter was found to remove fewer typical nitrogenous DBPs (Zheng et al. 2018).
Membrane technology is an emerging drinking water treatment technology employed in recent years. The commonly used membrane technologies are microfiltration, ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO), with descending order of membrane pore sizes (Gupta & Ali 2013). Compared with the traditional and advanced treatment processes, membrane technology has many advantages such as small footprints, a high degree of automation, easy management, eco-friendliness and stable quality of the treated water (Ahsan & Imteaz 2019). Nanofiltration, featuring pore sizes between those of UF and RO membranes, is a promising technology characterized by higher removal efficiency than UF but requiring lower operating pressure than RO. Nanofiltration has also been found to exhibit a significant removal effect on typical organics in drinking water, such as odorant substances, DBPs and endocrine disruptors (Yüksel et al. 2013; Dubowski et al. 2018). Several pilot and bench-scale studies have evaluated the effect of the NF process for drinking water treatment and found that the NF system can consistently provide higher-quality water (Chon & Cho 2016; Gonzalez et al. 2019).
The current study mainly evaluated the removal effect of NF membranes on typical organics such as odorants and trihalomethanes (THMs) in municipal tap water. In addition, other water quality indicators, including conductivity, turbidity, the removal effects of DOC and UVA254, were also analysed. Meanwhile, the removal effect of NF on organic matter with different characteristics was also explored through excitation–emission matrix (EEM) spectroscopy and high-performance size-exclusion chromatography (HPSEC).
MATERIALS AND METHODS
Pilot system
The pilot unit for this study was developed in the Suzhou Industry District Drinking Water Treatment Plant, China. As shown in Figure 1, the unit comprised the treatment process of the DWTP and an NF system. Surface water from Lake Tai was first treated by the coagulation–sedimentation–rapid sand filtration and disinfection process, and then, the obtained water was directly sent into an NF pilot system. A commonly used NF membrane NF 90 (DOW Filmtec, Midland, MI) was selected for this research. The properties of the virgin NF 90 membrane are summarized in Table 1 (Vatankhah et al. 2018). Since the feed water was disinfected by chlorine, a reducing agent was added to prevent the NF membrane from being damaged by residual chlorine in the water, and a security filter was set to remove particulates. The recovery rate was set to 29.80%, and the feed water pressure was set to 3.1 bar for continuous two months running. The initial permeate flux of water was 21.17 (L/m2·h).
Parameter . | NF90 . |
---|---|
NaCl removal rate | 85–95% |
MgSO4 removal rate | >97% |
Material | Polyamide, TFC |
Molecular weight cut-off (g/mol) | 200–300 |
Maximum pressure (bar) | 41 |
Maximum temperature (°C) | 45 |
pH | 3–10 |
Hydraulic resistance (m−1), 1013 | 4.0–7.7 |
Contact angle | 63.2° |
Free chlorine tolerance | <0.1 ppm |
Parameter . | NF90 . |
---|---|
NaCl removal rate | 85–95% |
MgSO4 removal rate | >97% |
Material | Polyamide, TFC |
Molecular weight cut-off (g/mol) | 200–300 |
Maximum pressure (bar) | 41 |
Maximum temperature (°C) | 45 |
pH | 3–10 |
Hydraulic resistance (m−1), 1013 | 4.0–7.7 |
Contact angle | 63.2° |
Free chlorine tolerance | <0.1 ppm |
Analytical methods
DOC was measured using a total organic carbon (TOC) analyzer (Aurora 1030 W, USA); UVA254 was determined using a UV-Vis spectrophotometer (Evolution 300, Loveland, USA); conductivity and total dissolved solids (TDS) were measured using a conductivity meter (DDS-307A, INESA instrument, China). Turbidity was measured with a turbidimeter (2100N, Hach Company, Loveland, USA). The concentration of 2-MIB and geosmin were measured by gas chromatography–mass spectrometry (GC-MS, 7890-7000C, Agilent, USA); the THMs of samples were determined by gas chromatography (7890A, Agilent, USA).
PARAFAC modelling
The 3D-EEM fluorescence spectra of samples of the raw water, feed water and permeated water were determined with a Hitachi Fluorescence Spectrophotometer-7100 (Japan) at room temperature (25 ± 2 °C), and the pH values of diluted samples were adjusted to 7.0 ± 0.1. Excitation–emission matrix scans were collected by scanning over emission (Em) wavelengths of 250–550 nm at 2 nm intervals and excitation (Ex) wavelengths of 200–400 nm at 2 nm intervals, with the scanning speed at 12,000 nm/min. The fluorescence signal of the pure water (Milli-Q water) was subtracted from the EEMs to remove Raman scatter peaks. The integrated area under the Raman scatter peak (Ex = 350 nm, Em = 381–426 nm) of the pure water was used for Raman unit (RU) normalization (Murphy et al. 2013). After EEM data pretreatment, a total of 66 fluorescence EEM spectra of water samples during the water pilot treatment were used for parallel factor (PARAFAC) analysis using MATLAB 7.1 based on the DOMFluor toolbox (Murphy et al. 2008). Only four samples were identified and removed using leverage comparison, and PARAFAC models with two to seven components were generated. Finally, a model of the four components was determined for further analysis using the split-half method.
High-performance size-exclusion chromatography analysis
The molecular weight (MW) distribution of TOC and the characteristics of UV fractions were examined using an HPSEC analysis instrument (Waters 4689, USA) connected with a Sievers900 online TOC analyser (GE, USA) and an online UV absorbance detector set at a wavelength of 254 nm (2,489 UV/VIS detector, Waters, USA).
RESULTS AND DISCUSSION
Effects of water plant and NF system on water quality improvement
A comprehensive sampling campaign was conducted from 7 April to 12 June 2019, throughout which the pilot process was continuously operated (over two months). Table 2 presents a summary of the mean and standard deviation measurements of the UVA254, DOC, specific UV absorbance (SUVA), conductivity, TDS and turbidity of the total 63 water samples. The source water was moderate in DOC (3.78 mg/L) and low in UVA254 (0.0.0525 cm−1), SUVA (1.394 L mg−1 m−1) and turbidity. During the experiment, the average conductivity and TDS of the raw water were 373.4 mS/cm and 186.7 mg/L, respectively. The UVA254, DOC and turbidity of the water were apparently reduced by the DWTP treatment, but the treatment had no effect on the conductivity and TDS. The conductivity and TDS of the finished water were higher than those of the raw water due to the addition of a coagulant in the coagulation process. However, the NF process could effectively reduce not only the organic matter but also the hardness.
Waters . | UVA254 (cm−1) . | DOC (mg/L) . | SUVA (L mg−1 m−1) . | Cond. (mS/cm) . | TDS (mg/L) . | Turb. (NTU) . |
---|---|---|---|---|---|---|
Raw | 0.0525 ± 0.004 | 3.78 ± 0.24 | 1.394 ± 0.12 | 373.4 ± 3.88 | 186.7 ± 2.11 | 9.69 ± 7.94 |
DWTP | 0.0356 ± 0.004 | 2.99 ± 0.16 | 1.202 ± 0.16 | 381.3 ± 5.16 | 190.87 ± 2.59 | 0.172 ± 0.07 |
NF | 0.0012 ± 0.002 | 0.21 ± 0.59 | 0.692 ± 0.59 | 20.6 ± 7.43 | 10.28 ± 3.77 | 0.049 ± 0.01 |
Waters . | UVA254 (cm−1) . | DOC (mg/L) . | SUVA (L mg−1 m−1) . | Cond. (mS/cm) . | TDS (mg/L) . | Turb. (NTU) . |
---|---|---|---|---|---|---|
Raw | 0.0525 ± 0.004 | 3.78 ± 0.24 | 1.394 ± 0.12 | 373.4 ± 3.88 | 186.7 ± 2.11 | 9.69 ± 7.94 |
DWTP | 0.0356 ± 0.004 | 2.99 ± 0.16 | 1.202 ± 0.16 | 381.3 ± 5.16 | 190.87 ± 2.59 | 0.172 ± 0.07 |
NF | 0.0012 ± 0.002 | 0.21 ± 0.59 | 0.692 ± 0.59 | 20.6 ± 7.43 | 10.28 ± 3.77 | 0.049 ± 0.01 |
As shown in Figure 2, for the NF treatment, the total percentage reductions in UVA254, DOC, SUVA, cond. and TDS were 95.90%, 92.06%, 65.70%, 94.59% and 94.61%, respectively. The DWTP yielded a 31.71% reduction in UVA254, 20.59% for DOC, 17.05% for SUVA, −2.04% for conductivity, −2.13% for TDS and 96.54% for turbidity. The removal efficiency of UVA254 was higher than that of DOC. This indicates that humic substances were removed more easily than the non-humic portion for the same DOC levels. The efficient reduction in conductivity and TDS by the NF membrane means a decrease in the ion concentration of the water, which can improve the taste of drinking water. Different from the conventional process, NF features membranes of very tiny pore sizes; thus, pollutants larger than the membrane pore size can be physically removed. Therefore, the NF process was efficient in the separation of impurities in water, and its effect on the improvement of drinking water quality was unmatched by the conventional process.
Removal effect of odour substances and THMs in drinking water
During the experiment, the removal effects for two typical odorant substances, 2-MIB and geosmin, were evaluated during the algal bloom time of Lake Tai. As can be seen in Figure 3(a), after treatment by the DWTP, the concentrations of 2-MIB and geosmin were reduced to 18.66 ng/L and 0.945 ng/L, respectively, with removal efficiencies of 54.63% and 47.35%, respectively. The conventional treatment could not reduce the 2-MIB to below the odour threshold concentration (9 ng/L). However, the geosmin content in the raw water was much lower than its threshold concentration (4 ng/L) (Kim et al. 1997). The NF process exhibited removal rates of 75.69% and 58.20% for 2-MIB and geosmin, respectively, with the concentrations reduced to 4.54 ng/L and 0.39 ng/L, respectively. The MW of 2-MIB is 168 Da, and that of geosmin is 182 Da; they are both smaller than the maximum MW cut-off of the selected NF membrane (200 Da) in this experiment. The removal of substances smaller than the NF membrane pore size mainly relies on the Donnan and dielectric effects and relates to the characteristics of the target pollutants (Cheng et al. 2012). The hydrophobicity/hydrophilicity (octanol–water partition coefficient, KOW) and charge (neutral or negative) of pollutants can affect the removal efficiency of the NF membrane (Amy et al. 2005).
As shown in Figure 3(b), after the disinfection process by the DWTP, the formation contents of CHCl2Br, CHBr3, CHCl3 and CHClBr2 were 17.87, 13.80, 9.17 and 7.53 μg/L, respectively. Trihalomethanes are formed due to the chlorination of water-containing organic compounds, principally humic and fulvic compounds (Waniek et al. 2002). The DBPs could not be removed effectively by the coagulation–sedimentation–rapid sand filtration process. After the treatment by NF, the concentrations of CHCl2Br, CHBr3, CHCl3 and CHClBr2 were 11.79, 9.10, 5.64 and 4.77 μg/L, corresponding to removal efficiencies of 34.02%, 34.06%, 38.49% and 36.65%, respectively. The MWs of CHCl2Br, CHBr3, CHCl3 and CHClBr2 are 163.8, 252.8, 119.4 and 208.3 Da, respectively. The removal rate shows that no correlation exists between the removal effect for the four kinds of THMs and their MWs. The pore size of the NF membrane employed in this study is believed to be larger than the target THMs; therefore, the NF process could not contribute to a high reduction. The overall lower DBP rejection by the NF appears to be related to size exclusion as well as solute–membrane affinity (Doederer et al. 2014).
However, the average concentrations of THMs in permeate water were substantially reduced after the NF treatment process. Disinfection is the last process in any water treatment plant. Therefore, if the DBP precursors cannot be effectively removed by the pretreatment process, they will react with chlorine. With the advantages of the flexibility of water plant design, NF can be used for the secondary improvement of drinking water at the end of the pipe network.
Changes in MW distributions of DOC and UVA254
Figure 4 shows the MW distribution of natural organic matter (NOM) for different fractions based on DOC and UVA254 measurements of raw water, feed water and permeate water. It can be found that the MWs of organic matter components in the raw water were mainly distributed between 200 Da and 30 kDa, and the peak positions of DOC and UVA254 appear at 3 kDa and 10 kDa, respectively. Generally, UVA254 represents the compounds whose molecular weights are larger than 3 kDa (Song et al. 2010). The water plant process could effectively remove organic matter components with MWs greater than 1 kDa, and DOC fractions of MWs less than 1 kDa were also partially removed, which can be attributed to their oxidative degradation by chlorine after chlorine addition. Organic matter components with MWs between 225 Da and 300 Da increased after the DWTP treatment. This phenomenon occurred in both DOC and UVA254 detection, and it may be related to the degradation of larger DOC due to chlorination. Nanofiltration membranes exhibited a significant removal effect on organic compounds of all MWs. Larger-molecular-weight organics could be completely retained by the NF membrane, but Figure 4 shows a smaller DOC response peak located at 1,000–1,500 kDa, and the DOC response peak of the feed water is also at this position. A higher solute concentration was present at the membrane surface due to the gradual increase of the rejected solute near the membrane surface (Hilal et al. 2008).
As shown in Figure 5, the area integration method was used to analyse the changes in different organic matter components according to their MWs. The MW distribution of NOM was fractionated corresponding to the fractions of <1, 1–3, 3–10 and >10 kDa (Chen et al. 2007). Changes in the integrated areas of DOC and UVA254 in different MW ranges can indirectly reflect the changes in the concentration of organic matter in the corresponding MW range. The NF process removed 91.20%, 87.66%, 78.41%, 98.99% and 100% of the DOC area with fractions of <1, 1–3, 3–10 and >10 kDa, respectively. The corresponding removal rates of the UVA254 area for different components were 65.82%, 95.19%, 95.01%, 94.59% and 100%, respectively. The removal effect of UVA254 with MW <1,000 Da was much lower than those of the other four components. The removal rate increased with the increase in MW. For substances with MWs larger than the MW cut-off of the membrane, the removal mechanism of the NF membrane is mainly interception screening; however, many studies have shown that the NF membrane still has a good removal effect on organic substances smaller than its pore size. This is mainly because the surfaces of most NF membranes are negatively charged. Donnan and dielectric effects can also effectively ensure the removal of ions and partially charged small-molecular-weight organic matter.
Changes in PARAFAC fluorescence components
PARAFAC analysis (with two to seven components) was performed on the total 62 water samples. However, only three, four and five components could be validated by the split-half method. Tucker's congruence coefficients were applied to check the similarity of excitation and emission loadings. Tucker's congruence coefficient greater than 0.95 indicates that the factors can be considered to be equal, and only the four-component model could be validated in this research. Figure 6 and Table 3 show the four-component PARAFAC model and the positions of the spectral characteristics of the 62 EEMs in this study. Component 1 (C1) showed two excitation maximums at 206 and 276 nm with a single emission maximum at 320 nm and was thus identified as tryptophan-like substances. Component 2 (C2) can be regarded as amino acids (Ex = 228, Em = 344). Component 3 (C3) belongs to terrestrial/anthropogenic humic substances (Ex = 252, Em = 450), and component 4 (C4) had a protein-like structure and was similar to tyrosine-like substances (Ex = 200, Em = 298). After validation of the four-component model, the fate of the components across the pilot study was tracked using their maximum fluorescence intensities (Fmax).
Component . | Ex . | Em . | Description and probable source . |
---|---|---|---|
Component 1 | 206, 276 | 320 | tryptophan-like substances (Stedmon & Markager 2005) |
Component 2 | 228 | 344 | amino acids (Baghoth et al. 2011) |
Component 3 | 252 | 450 | terrestrial/anthropogenic humic substances (Murphy et al. 2006) |
Component 4 | 200 | 298 | tyrosine-like substances (Xu et al. 2013) |
Component . | Ex . | Em . | Description and probable source . |
---|---|---|---|
Component 1 | 206, 276 | 320 | tryptophan-like substances (Stedmon & Markager 2005) |
Component 2 | 228 | 344 | amino acids (Baghoth et al. 2011) |
Component 3 | 252 | 450 | terrestrial/anthropogenic humic substances (Murphy et al. 2006) |
Component 4 | 200 | 298 | tyrosine-like substances (Xu et al. 2013) |
To analyse the effect of water treatment on the fluorescence characteristics of NOM, the mean percentage reductions of Fmax across the DWTP and NF treatment processes (Figure 7) were computed. For the raw water samples, mean Fmax was 1.36, 1.04, 0.30 and 0.62 RU for C1, C2, C3 and C4, respectively. The result indicates that the samples were dominated by tryptophan-like fluorescent compounds. The DWTP exhibited a very weak removal effect on the fluorescent organic compounds of components C1, C2, C3 and C4; the removal rates were 4.78%, 6.96%, 20.63% and 14.52%, respectively, while the corresponding removal efficiencies of the NF process reached 97.66%, 97.55%, 96.89% and 66.97%, respectively. Compared with the DWTP process, the NF process showed a significant effect on the removal of fluorescent organic matter in drinking water. The mean percentage reduction of fluorescence is comparable to that of DOC in the case of the conventional treatment (∼5–20% for fluorescence and ∼17% for DOC). The NF process could almost completely remove components C1, C2 and C3 and was only ineffective in removing component C4. Humic acid and fulvic acid organic matter have higher MW and firmer structure and are difficult for microorganisms to decompose (Allpike et al. 2005); therefore, they could be effectively removed. However, component C4 was mainly a tyrosine-like substance. Studies have shown that these substances are positively correlated with the content of active dissolved organic matter (DOM) components. Free-form amino acids have small MWs and can be rapidly utilized by heterotrophic microorganisms (Cory & Kaplan 2012); therefore, component C4 was not easily retained by the NF membrane.
Correlations
All water samples were included in the determination of Spearman's correlation coefficients. Table 4 presents a correlation matrix obtained with SPSS statistical software. Significant correlation (p < 0.01) exists between the DOC concentration and Fmax of three PARAFAC components (C1, C2 and C3) as well as between UVA254 and Fmax. This is because the removal rate of the C4 component by the NF process was not as high as those of the other three components. The removal rates of DOC, UVA254, C1, C2 and C3 by the NF process were 95.90%, 92.06%, 97.66%, 97.55% and 96.89%, respectively, while the removal rate of component C4 was only 66.97%. Moreover, SUVA had poor correlations with DOC, UVA254 and Fmax of C1, C2, C3 and C4. This result is expected since the water treatment process presented similar removal rates of UVA254 and DOC. Thus, the SUVA value was not significantly changed. From the correlation analysis, it can be seen that three-dimensional fluorescence can not only characterize the changes in the organic matter concentration but also monitor abnormal components that cannot be effectively removed from the water. The higher predictive ability of Fmax allows its use as an alternative to UVA254 and DOC for online monitoring of DOM concentration in DWTPs. Furthermore, the higher sensitivity of fluorescence measurements provides more reliable information for water quality analysis during the treatment and distribution of drinking water.
. | DOC . | UVA254 . | SUVA . | C1 . | C2 . | C3 . | C4 . |
---|---|---|---|---|---|---|---|
DOC | 1 | 0.976** | 0.649* | 0.935** | 0.939** | 0.935** | 0.681 |
UVA254 | 1 | 0.571* | 0.961** | 0.968** | 0.948** | 0.667* | |
SUVA | 1 | 0.594* | 0.594* | 0.576* | 0.447 | ||
C1 | 1 | 0.981* | 0.925** | 0.764 | |||
C2 | 1 | 0.965** | 0.731* | ||||
C3 | 1 | 0.694* | |||||
C4 | 1 |
. | DOC . | UVA254 . | SUVA . | C1 . | C2 . | C3 . | C4 . |
---|---|---|---|---|---|---|---|
DOC | 1 | 0.976** | 0.649* | 0.935** | 0.939** | 0.935** | 0.681 |
UVA254 | 1 | 0.571* | 0.961** | 0.968** | 0.948** | 0.667* | |
SUVA | 1 | 0.594* | 0.594* | 0.576* | 0.447 | ||
C1 | 1 | 0.981* | 0.925** | 0.764 | |||
C2 | 1 | 0.965** | 0.731* | ||||
C3 | 1 | 0.694* | |||||
C4 | 1 |
*At level 0.05 (two-tailed), the correlation is significant. **At level 0.01 (two-tailed), the correlation is significant.
CONCLUSIONS
Pilot-plant studies were carried out to evaluate water quality improvement by NF, and the following conclusions can be drawn.
- 1.
The NF membrane could effectively improve the drinking water quality; the NF treatment further removed both odour substances and THMs.
- 2.
Organic matter components with MWs between 225 and 300 Da increased after the DWTP treatment; the NF process could remove parts of the NOM with MWs less than 200 Da. Nanofiltration exhibited a significant removal effect on organic matter components of all MWs.
- 3.
Four fluorescent components (C1, C2, C3 and C4) were identified in all the samples by EEM-PARAFAC analysis. Compared with the DWTP process, components C1, C2 and C3 were significantly removed by the NF membrane, but component C4 reached the permeate water. Further analysis including HPSEC showed that component C4 seemed to be related to organic matter with MW between 1,000 and 1,500 Da in the membrane water.
- 4.
The indicators DOC and UVA254 showed significant correlations with components C1, C2 and C3 but were less correlated with component C4.
- 5.
Further research on the detailed characteristics of NOM in permeate water is needed, and a direct relationship between the fluorescence component and the real concentration of DOM needs to be established.
ACKNOWLEDGEMENTS
This work was supported by the International Science and Technology Cooperation Program of China (2016YFE0123700), the Major Science and Technology Program for Water Pollution Control and Treatment (2017ZX07201001), the Natural Science Foundation of China (No. 51708130), College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China and School of the Environment and Municipal Administration, Lanzhou Jiaotong University, Lanzhou 730070, China. Special thanks to my supervisor, Professor YanChen.
DATA AVAILABILITY STATEMENT
Due to the cooperation between this research project and the water treatment plant, data disclosure needs to be negotiated with other units. If the cooperation units all agree to the publication of the paper data, we will submit it as soon as possible.