The horizontal screen is one of the energy dissipater structures used on the brink of vertical drop. These structures increase the energy dissipation and the turbulence in the flow by causing air entrainment. In the present study, the effect of the diameter of the screen with constant porosity at three different diameters on the hydraulic parameters of the vertical drop was investigated. The experiments were performed in the relative critical depth range of 0.13 to 0.39. The results showed that by increasing the relative diameter of the horizontal screen, the relative wetting length and turbulence length increased, the residual energy remained constant and the pool depth decreased. Compared to the stilling basin, the horizontal screen significantly reduces turbulence length and residual energy. The results also showed that the application of horizontal screens at the brink of the drop, with and without a downstream rough bed, could be a suitable alternative for a stilling basin.

  • The horizontal screen is one of the energy dissipator structures used on the brink of vertical drop and increases the energy dissipation and the turbulence in the flow by causing air entrainment.

  • The diameter of the screen holes plays a role in increasing the mixing length.

  • Vertical drop equipped with a horizontal screen reduces the residual relative energy by 30% compared to the stilling basin.

Vertical drops also known as a grade control, or over-fall, is typically built in irrigation channels to pass water to a lower elevation or used in mountainous areas to reduce the steep slopes. Flow downstream of the drops, due to the slope, has a destructive kinetic energy. If this destructive energy is not controlled and reduced, downstream structures will be exposed to erosion and destruction. A hydraulic jump in the stilling basin is therefore commonly used to reduce energy (Fathi-Moghadam et al. 2017; Kabiri-Samani et al. 2017).

The first basic studies on vertical drops were made in 1932 by Bakhmeteff (1932). He presented an equation to calculate the downstream water depth of a drop by assuming flow momentum, a hydrostatic distribution of pressure and a uniform distribution of velocity. Rouse (1936) developed an equation to estimate the discharge in a vertical drop. Subsequently, extensive experimental studies have been performed to characterize the flow over a simple vertical drop. Many of these researchers investigated the total energy loss and the hydraulic parameters for plain vertical drops (White 1943; Rand 1955; Akram Gill 1979; Rajaratnam & Chamani 1995; Chamani et al. 2008). Esen et al. (2004) studied the energy dissipation of vertical drops with several steps taking into account different downstream dimensions: as the step height increased, the energy loss and the drop vertical downstream depth increased. Hong et al. (2010) measured the force and drop length with a positive slope downstream of a vertical drop. They provided equations for estimating the force and drop length and showed that by increasing the bed slope, the drop length and force on the downstream bed increased. Liu et al. (2014) investigated the influence of a positive slope upstream of a vertical drop. Their results revealed that the brink depth, the pool depth and the angle of the falling jets decrease with such slopes. The influence of tailwater depth on the vertical hydraulic performance of the vertical drop equipped with grid dissipaters was also studied experimentally by Sharif & Kabiri-Samani (2018). The results showed that as the tailwater depth increases, air entrainment decreased.

The first studies on screens were performed by (Rajaratnam & Hurtig 2000) as energy-decreasing devices. Çakir (2003) carried out experiments on screens and showed that the use of screens for energy dissipation is effective. They also found that the thickness of the screens has an insignificant effect on energy dissipation. Studies were also carried out on the use of vertical screens; the results showed that the thickness of the screen had no effect on the energy loss but modifications in the number of screens and the shape of the square aperture had an impact (Aslankara 2007; Mahmoud et al. 2013; Sadeghfam et al. 2019). Sadeghfam et al. (2014) studied dual vertical screens for energy dissipation with two different porosity ratios. They found that dual screens are much more able to reduce energy compared to either free or submerged hydraulic jumps. Daneshfaraz et al. (2017) numerically investigated energy dissipation caused by the use of vertical screens along with a baffle block downstream of a gate. The results revealed that the block models have more energy dissipation than the non-block models.

Recently, the application of a horizontal screen at the brink of a vertical drop has been considered as a horizontal dissipater. Air entrainment is one of the factors commonly used for energy loss. These plates increase the energy loss by creating several falling jets and increasing turbulence downstream of the vertical drop. Screens on a vertical drop brink were studied by Kabiri-Samani et al. (2017). The results of their study revealed that when a vertical drop is equipped with screens, there is a decrease in the total length of the stilling basin downstream of the structures by about 60–75%. Sharif & Kabiri-Samani (2018) also investigated the effect of tailwater depth on a vertical drop equipped with a screen. The results showed that by increasing the tailwater depth, air entrainment decreases and the relative pool depth increases. Hasanniya (2019) investigated the hydraulic parameters of a vertical drop equipped with a horizontal screen with the subcritical flow. The results revealed that the relative depth of the pool, the relative downstream depth and reduction in the total energy of the system increase.

From this prior research, it is evident that the simultaneous application of a vertical drop and a horizontal screen can lead to a significant increase in energy loss downstream of these structures. There is still a significant need to better understand and analyze the geometric parameters affecting the hydraulic performance of a horizontal screen. Consequently, the current study aims to investigate the performance of the vertical drop equipped with a horizontal screen with constant porosity at three different diameters of holes. To validate the obtained results, the current study is also compared with previous research data.

Figure 1 shows the physical and hydraulic parameters of the flow for a vertical drop equipped with horizontal screens; these parameters are indicated in Equation (1):
(1)
where Q is the flow discharge, H is the vertical drop height, P is the porosity of screen, y0 is the upstream depth, yc is the critical depth (yc=(q2/g)1/3), y1 is the downstream depth, yp is the pool depth, Lwet is the wetted length of the screen, LD is the mixing length of the pool, D is the diameter of hole in screen, E0 is the total energy upstream of the drop, E1 is the specific energy downstream of the drop, ρ is the density of water, μ is the dynamic viscosity and g is the gravitational acceleration.
Figure 1

Illustration of the flow features and view of the test section and flumes.

Figure 1

Illustration of the flow features and view of the test section and flumes.

Close modal
Using the π-Buckingham's theorem and with ρ, g and H as repeated variables, the relative mixing length of the pool was obtained on the basis of the independent dimensionless parameters in Equation (2):
(2)
By applying the same method, Equation (3) was obtained for the wetted length of horizontal screens, the depth of the pool and the normalized residual energy:
(3)
Here, Re0 is the upstream Reynolds number, Fr0 is the upstream Froude number, D/H is the relative diameter of hole in screen, yp/H is relative pool depth, yc/H is relative critical depth, Lwet/yc is relative wetting length of screen, LD/H is relative drop length and E1/E0 is is the normalized residual energy. Since the upstream Reynolds number is between 4,879 and 18,920, the flow is quite turbulent and the effect of the dynamic viscosity and the Reynolds number can be neglected (Di Francesco et al. 2015; Biscarini et al. 2016; Mahtabi et al. 2020). According to the studies by Daneshfaraz et al. (2020c and 2021), the porosity of horizontal screen has no effect on the relative residual energy. Moreover, the 50% porosity of the plates leads to a wetting length of screen and a mixing length of the pool smaller than a 40% porosity one. In the present study, therefore, the porosity of horizontal screen was considered to be 50%. The flow upstream of the vertical drop is subcritical and the Froude numbers are low (0.69Fr00.86), so the effect of this parameter on Equations (2) and (3) is neglected (Azamathulla & Ahmad 2012; Kabiri-Samani et al. 2017). Finally, Equations (4) and (5) are modified as follows:
(4)
(5)

Experimental setup

The experiments were performed in a horizontal, rectangular cross-section channel with Plexiglas walls and a length, width and height of 5 m, 0.3 m and 0.45 m, respectively. The vertical drop height and length were H = 0.15 m and L = 1.20 m. A polyethylene horizontal screen 1 cm thick and 0.3 × 0.7 m spanned the width of the channel. The screens included a zigzag of circular openings with constant porosity at three diameters of 1 cm, 2 cm and 3 cm. At the inlet of the channel, there is a screen that eliminates the flow turbulence and the flow slowly enters the laboratory flume. With plexiglass, the influence of sidewall effects is considered to be negligible based upon the findings of Johnson (1996) and Moradinejad et al. (2019). Channel flow was measured by two pumps each at a maximum discharge of 7.5 L/s by two valves connected to two rotameters with an accuracy of ±2%, installed at the pump outlet. To ensure steady flow, the vertical drop was installed 1.5 m downstream of the inlet tank. At the inlet of the channel, there was a screen that eliminated the flow turbulence to allow the flow to slowly enter the laboratory flume. In total, 42 experiments were performed to investigate the research objectives. Figure 1 illustrates the experimental model of the present study. After stabilizing the flow conditions, the upstream depth, wetted length of the screen, mixing length of the pool, depth of the pool and depth downstream were measured. The flow depth for both the upstream and downstream sections was determined using a gauge point mounted on the flume top with an accuracy of ±1 mm. This measuring instrument was adopted from previous studies, including Daneshfaraz et al. (2020a; 2020b) and Ghaderi et al. (2020a; 2020b). To record the upstream flow depth, the gauge point was positioned at 3 H to 4 H (Ackers et al. 1978; Ghaderi et al. 2020c). Also, the flow depth was recorded downstream of the vertical drop at a distance of 1 m. In total, the depth at five locations was measured and the average value was used. A ruler with a precision of 1 mm was used to measure the respective lengths. Figure 2 illustrates a flow structure of the experimental model and the investigated ranges of the parameters are presented in Table 1.

Table 1

Investigated ranges of parameters

Parameters
D/HQ (L/s)Fr0y0 (cm)y1 (cm)yc (cm)yp (cm)LD (cm)Lwet (cm)
0.067 2.5–13.5 0.69–0.86 2.45–6.50 2.6–7.1 1.92–5.86 3.7–10.3 16–49 8–41 
0.133 2.5–13.5 0.69–0.86 2.45–6.50 2.8–7 1.92–5.86 3.5–9.8 21–58 8.5–45 
0.2 2.5–13.5 0.69–0.86 2.45–6.50 2.8–7.1 1.92–5.86 3.2–9.8 24–62 9–49.5 
Parameters
D/HQ (L/s)Fr0y0 (cm)y1 (cm)yc (cm)yp (cm)LD (cm)Lwet (cm)
0.067 2.5–13.5 0.69–0.86 2.45–6.50 2.6–7.1 1.92–5.86 3.7–10.3 16–49 8–41 
0.133 2.5–13.5 0.69–0.86 2.45–6.50 2.8–7 1.92–5.86 3.5–9.8 21–58 8.5–45 
0.2 2.5–13.5 0.69–0.86 2.45–6.50 2.8–7.1 1.92–5.86 3.2–9.8 24–62 9–49.5 
Figure 2

Flow structure of the experimental model of the present study: (a) top view, (b) side view.

Figure 2

Flow structure of the experimental model of the present study: (a) top view, (b) side view.

Close modal

Calculations

The downstream Froude number (Frd) is calculated using Equation (6) (Rand 1955):
(6)
Prior researchers, for instance Esen et al. (2004), presented their studies using the relative downstream depth, as in Equation (7):
(7)
The Froude number of downstream of the plain vertical drop can therefore be expressed as:
(8)
In the present study, the relative critical depth range is between 0.13 and 0.39, and so the range of the downstream Froude number of plain vertical drop is 3.9 to 5.3. If a Type I stilling basin downstream of the drop is used to dissipate the flow energy, the total drop length is obtained from Equation (9) (see in Figure 3):
(9)
Figure 3

Vertical drop schematics equipped with a downstream stilling basin.

Figure 3

Vertical drop schematics equipped with a downstream stilling basin.

Close modal
In the Equation (9), Lds/H and Lb/H are the relative lengths of the plain vertical drop and the stilling basin downstream of the vertical drop, respectively. They can be calculated from the following equations, where H is the vertical drop height:
(10)
(11)

In order to validate the results of a vertical drop, results from the present study were compared with those of Rajaratnam & Chamani (1995) (Figure 4), which showed a good agreement. Moreover, the performance criteria (the determination coefficient (R2) and the normalized root-mean-square error (NRMSE)) were calculated and are presented in Table 2.

Table 2

Performance metrics related to comparison of the present results with those of the Rajaratnam & Chamani (1995) 

Comparison parametersR2NRMSE
yp/H 0.925 0.037 
E1/E0 0.980 0.01 
Comparison parametersR2NRMSE
yp/H 0.925 0.037 
E1/E0 0.980 0.01 
Figure 4

Comparison of the relative pool depth for a vertical drop and normalized residual energy of the present study with the results of Rajaratnam & Chamani (1995).

Figure 4

Comparison of the relative pool depth for a vertical drop and normalized residual energy of the present study with the results of Rajaratnam & Chamani (1995).

Close modal

The existence of horizontal screens, with turbulence in the falling water jet and air entrainment, causes a loss of the jet. The wetted length, mixing length, pool length and residual downstream energy were measured and calculated.

Relative wetted length

The length of the screen that the flow passes through its holes is called the wet length of the screen (see Figure 5). Since the relative wetted length (Lwet/yc) can be used to optimize vertical drops with horizontal screens, it is important to investigate the influence of this parameter. Figure 6 shows the relative wetted length versus the Froude number, taking in account three relative diameters of the screen porosities.

Figure 5

The wetted length on the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Figure 5

The wetted length on the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Close modal
Figure 6

Relative wetted length versus the Froude number.

Figure 6

Relative wetted length versus the Froude number.

Close modal

It can be seen that as the upstream Froude number increases, the flow velocity increases at the screen. Consequently, there is less flow through each grid opening and the wetted length of the screen for three relative diameter of hole in screen increases. It is also observed that as the relative diameter of the horizontal screens increases, the relative wetted length increases. Therefore, it can be claimed that in the constant porosity of the screen, by increasing the diameter of the screen holes, the total circumference of the screen holes decreases and the relative wetted length increases. Therefore, similar to the case of nonlinear weir (i.e. labyrinth weir), by decreasing the circumference of the screen holes, the flow rate through them decreases and the wetting length increases (Abbasi et al. 2021). The results show that the relative wetted length of the screens with a relative diameter of 0.133 and 0.2 increases by 11 and 18.5%, respectively, compared to the screen with a relative diameter of 0.067.

Equation (12) was used to estimate the relative wetted length of the horizontal screens with three relative screen diameters of the present study:
(12)

Equation (12) leads to an R2 and NRMSE of 0.96 and 0.023, respectively. This equation estimates laboratory values of relative wetted length with a maximum relative error of 6.1%. Figure 7 shows the comparison between the laboratory and calculated values of the relative wetted length.

Figure 7

Comparison of the measured and calculated values using Equation (12) for the relative wetted length.

Figure 7

Comparison of the measured and calculated values using Equation (12) for the relative wetted length.

Close modal

Relative pool depth

The falling jets, after impacting with the downstream bed, causes some flow to return to the vertical drop wall and form a pool behind the jet. The depth formed by the back flow near the wall of the vertical drop structure is called the pool depth (see Figure 8).

Figure 8

The pool depth downstream of the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Figure 8

The pool depth downstream of the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Close modal

In Figure 9 shows the relative depth of the pool at three relative diameters of the screen versus the relative critical depth. It can be seen that by increasing the relative critical depth, the relative depth of the pool increases in all three relative diameters. Also, the pool's relative depth values of the present research for the relative diameter of 0.067 are in good agreement with Hasanniya's (2019) studies for the same relative diameter. According to Figure 9, for the vertical drop with a horizontal screen for three relative diameter of the screen, the pool depth is increased compared to the plain vertical drop (reported by Rajaratnam & Chamani 1995). This increase is due to the increase in the angle of the falling jet for the vertical drop equipped with a horizontal screen, compared to the absence of screens. In addition, the application of horizontal screens at the brink of a vertical drop creates a large number of submerged jumps in the pool that also increase the relative pool depth. It is observed that the relative depth of the pool decreases with increasing the hole diameter of the horizontal screen. By increasing the diameter of the screen, the angle of jet from the screen is reduced and the relative pool depth is decreased.

Figure 9

Relative pool depth changes versus relative critical.

Figure 9

Relative pool depth changes versus relative critical.

Close modal

Compared to the horizontal screen with a relative diameter of 0.067, the use of a screen with a relative diameter of 0.2 reduced the relative depth of the pool by 8.5%.

For the laboratory data, Equation (13) was used to estimate the relative depth of the pool with three relative screen diameters of the present study.
(13)

Equation (13) leads to an R2 and NRMSE of 0.98 and 0.037, respectively. This equation estimates laboratory values of relative depth of the pool with a maximum relative error of 5.4%. Figure 10 shows the comparison between the laboratory and calculated values of the relative depth of the pool.

Figure 10

Comparison of the measured and calculated values using Equation (13) for the relative depth of the pool.

Figure 10

Comparison of the measured and calculated values using Equation (13) for the relative depth of the pool.

Close modal

Relative length of drop (mixing length)

Passing strip jets through the horizontal screen, causing numerous jumps in the pool, creates a uniform depth downstream of the drop. The longitudinal distance from the brink of the drop to the section where the downstream depth of the flow becomes uniform and the air bubbles entering the flow are not visible, is called the ‘mixing length’ (see Figure 11).

Figure 11

The mixing length from flow passes through the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Figure 11

The mixing length from flow passes through the vertical drop equipped with a horizontal screen with Q = 8.5 L/s (a) D/H = 0.067 (b) D/H = 0.113 (c) D/H = 0.2.

Close modal

Figure 12 illustrates the variations in the mixing length of the drop versus the relative critical depth for three relative diameters of the holes of the screen. It is seen that as the relative critical depth increases, the mixing length of the drop for three relative diameters increases. Also, the mixing length values of the present research in the relative diameter of 0.067 are in good agreement with the results of the Hasanniya (2019) studies in the same relative diameter. By increasing the relative diameter of the screen, the mixing length also increases. The reason for this is the increase in air entrainment due to the collision of falling jets with a high diameter hole in the screen. Since the air bubbles created by the air entrainment tend to move along with the flow, therefore, the movement of these bubbles to downstream causes an increase in the mixing length.

Figure 12

The relative drop length versus relative critical depth.

Figure 12

The relative drop length versus relative critical depth.

Close modal

According to Figure 12, it is observed that the utilization of screens significantly reduces the drop length compared to the utilization of a Type 1 stilling basin. The vertical drop length gradient with horizontal screens in the present study is also lower compared to the vertical drop with a Type 1 stilling basin. This means that the greatest decrease in the length of the vertical drop occurs in the higher critical depth compared to using a stilling basin. Screens with relative diameters of 0.2 and 0.133 increase the mixing length by 15% and 27%, respectively, compared to screens with relative diameters of 0.067.

Equation (14) was used to estimate the mixing length with three relative diameters of screen in the present study:
(14)

Equation (14) leads to an R2 and NRMSE of 0.96 and 0.023, respectively. This equation estimates laboratory values of relative depth of the pool with a maximum relative error of 5.7%. Figure 13 shows the comparison between the laboratory and calculated values of the mixing length.

Figure 13

Comparison of the measured and calculated values using Equation (14) for the relative drop length.

Figure 13

Comparison of the measured and calculated values using Equation (14) for the relative drop length.

Close modal

Normalized residual energy

The normalized residual energy is equal to the difference between downstream and upstream energy. Figure 14 shows the normalized residual energy values for three relative diameters of screen. It is observed that the normalized residual energy increases with relative critical depth. The normalized residual energy values of the present study are in close and appropriate agreement with the results of Hasanniya (2019) studies. It is seen that the relative diameter of the screen has very little effect on normalized residual energy of the vertical drop equipped with a horizontal screens. The increase in air entrainment due to the collision of falling jets created in the horizontal screens has reduced the normalized residual energy, compared to the stilling basin (in all three relative diameters of the screen by 31% on average).

Figure 14

Normalized residual energy changes versus relative critical depth.

Figure 14

Normalized residual energy changes versus relative critical depth.

Close modal

In the present study, the hydraulic parameters of the vertical drop equipped with a horizontal screen were investigated by considering three different relative diameters of holes. The experiments were performed using a constant screen porosity and a relative critical depth ranging from 0.13 to 0.39. The parameters of relative wetted length, relative pool depth, mixing length and normalized residual energy were investigated. The following results can be drawn:

  • By increasing the diameter of the screen holes, the wetted length of the screens increases. The screen with relative diameters of 0.2 increases the wetted length by 18.5% compared to the screen with relative diameters of 0.067.

  • The depth of the pool decreases with an increase in the relative diameter of the screen. The screen with a relative diameter of 0.2 has the lowest values of the depth of the pool.

  • The relative diameter of the screen is inversely related to the mixing length and the use of these screens reduces the mixing length by more than 38%.

  • The relative diameter of the screen has no effect on the normalized residual energy of the vertical drop; however, using the vertical drop equipped with a horizontal screen reduces the residual relative energy by 30% compared to the stilling basin.

  • If it is possible to prevent the obstruction of the openings of the horizontal screens against the debris flow with appropriate solutions, according to the results, it can be considered as an alternative to a stilling basin downstream of the vertical drop.

The range of the Froude number downstream of the vertical slope in the present study is between 3.9 and 5.3. A Type 1 stilling basin is commonly used to dissipate energy downstream of the vertical drop (Rand 1955). In the design of stilling basins, an attempt is usually made to make the hydraulic jump inside the basin, and this requires to take into account the tailwater depth. To form the hydraulic jump inside the stilling basin, the end sill or a change in the pond bed level are sometimes used. However, the horizontal screen at the vertical drop does not require the tailwater depth to reduce the normalized residual energy or to form the hydraulic jump. It also reduces the normalized residual energy further with respect to the stilling basin. On the other hand, due to the decrease in the relative energy of the horizontal screen compared to the stilling basin, it is obvious that these screens have a lower relative tailwater depth. Therefore, using horizontal screens at the vertical drop compared to stilling basin has the following advantages:

  • There is no need for the tailwater depth, or to take into account the arrangements for the hydraulic jump inside the stilling basin.

  • There is a reduction in the size of the stilling basin required for energy dissipation due to a decrease in the mixed length.

  • There is a decrease in the normalized residual energy or an increase in flow energy dissipation

However, due to their emergence, these screens have not been implemented in practical projects so far, and if they are implemented, they also have disadvantages. Flow containing suspended sediment and debris flow in channel and irrigation networks are one of the serious problems that can affect the hydraulic performance by blocking the openings of the screen. The size of the diameter of these screens can be effective in preventing them from clogging the hole and this requires further investigation. According to the results, considering all the hydraulic conditions and the advantages and disadvantages of the horizontal screen as an energy dissipater structure, these screens can be used as an alternative to the stilling basin downstream of the vertical drop as long as an inspection for obstructions against the debris flow has been carried out.

All relevant data are included in the paper or its Supplementary Information.

Ackers
P.
White
W. R.
Perkins
J. A.
Harrison
A. J.
1978
Weirs and Flumes for Flow Measurements
.
Wiley
,
Chichester
,
UK
.
327
.
Akram Gill
M.
1979
Hydraulics of rectangular vertical drop structures
.
Journal of Hydraulic Research
17
(
4
),
289
302
.
https://doi.org/10.1080/00221687909499573
.
Aslankara
V.
2007
Experimental Investigation of Tailwater Effect on the Energy Dissipation Through Screens
.
MSc thesis
,
Middle East Technical Univ. Ankara
,
Turkey
.
Azamathulla
H. M.
Ahmad
Z.
2012
GP approach for critical submergence of intakes in open channel flows
.
Journal of Hydroinformatics
14
(
4
),
937
943
.
Bakhmeteff
M. W.
1932
Hydraulics of Open Channels
.
McGraw-Hill Inc
,
New York and London
.
Çakir
P.
2003
Experimental Investigation of Energy Dissipation Through Screens
.
Doctoral dissertation, MSc thesis
,
Department of Civil Engineering, Middle East Technical University
,
Ankara, Turkey
.
Chamani
M. R.
Rajaratnam
N.
Beirami
M. K.
2008
Turbulent jet energy dissipation at vertical drops
.
Journal of Hydraulic Engineering
134
(
10
),
1532
1535
.
https://doi.org/10.1061/(ASCE)0733-9429(2008)134:10(1532)
.
Daneshfaraz
R.
Sadeghfam
S.
Ghahramanzadeh
A.
2017
Three-dimensional numerical investigation of flow through screens as energy dissipators
.
Canadian Journal of Civil Engineering
44
(
10
),
850
859
.
https://doi.org/10.1139/cjce-2017-0273
.
Daneshfaraz
R.
Ghaderi
A.
Akhtari
A.
Di Francesco
S.
2020a
On the effect of block roughness in ogee spillways with flip buckets
.
Fluids
5
(
4
),
182
.
Daneshfaraz
R.
Asl
M. M.
Razmi
S.
Norouzi
R.
Abraham
J.
2020b
Experimental investigation of the effect of dual horizontal screens on the hydraulic performance of a vertical drop
.
International Journal of Environmental Science and Technology
17
,
2927
2936
.
Daneshfaraz
R.
Majedi Asl
M.
Razmi
S.
2020c
Experimental investigation of the effect of dual horizontal screens on the hydraulic performance of a vertical drop
.
International Journal of Environmental Science and Technology
17
,
2927
2936
.
https://doi.org/10.1007/s13762-019-02622-x
.
Di Francesco
S.
Biscarini
C.
Manciola
P.
2015
Numerical simulation of water free-surface flows through a front-tracking lattice Boltzmann approach
.
Journal of Hydroinformatics
17
(
1
),
1
6
.
Esen
I. I.
Alhumoud
J. M.
Hannan
K. A.
2004
Energy loss at a drop structure with a step at the base
.
Water International
29
(
4
),
523
529
.
https://doi.org/10.1080/02508060408691816
.
Fathi-Moghadam
M.
Kiani
S.
Asiaban
P.
Behrozi-Rad
R.
2017
Modeling of perforated sill-controlled hydraulic jump
.
International Journal of Civil Engineering
15
(
4
),
689
695
.
https://doi.org/10.1007/s40999-017-0185-8
.
Ghaderi
A.
Daneshfaraz
R.
Dasineh
M.
Di Francesco
S.
2020a
Energy dissipation and hydraulics of flow over trapezoidal-triangular labyrinth weirs
.
Water (Switzerland)
12
(
7
).
https://doi.org/10.3390/w12071992
.
Ghaderi
A.
Daneshfaraz
R.
Torabi
M.
Abraham
J.
Azamathulla
H. M.
2020b
Experimental investigation on effective scouring parameters downstream from stepped spillways
.
Water Supply
20
(
5
),
1988
1998
.
Ghaderi
A.
Abbasi
S.
Abraham
J.
Azamathulla
H. M.
2020c
Efficiency of trapezoidal labyrinth shaped stepped spillways
.
Flow Measurement and Instrumentation
72
,
101711
.
Hasanniya
V.
2019
Experimental Investigation of Flow Energy Dissipation Through the Application of the Screen in Drops
.
MSc thesis
,
Civil Engineering Department, Faculty of Engineering, University of Maragheh
,
Maragheh
,
Iran
.
Hong
Y. M.
Huang
H. S.
Wan
S.
2010
Drop characteristics of free-falling nappe for aerated straight-drop spillway
.
Journal of Hydraulic Research
48
,
125
129
.
https://doi.org/10.1080/00221680903568683
.
Johnson
M.
1996
Discharge Coefficient Scale Effects Analysis for Weirs
.
PhD dissertation
,
Utah State University
,
Logan, Utah
.
Kabiri-Samani
A. R.
Bakhshian
E.
Chamani
M. R.
2017
Flow characteristics of grid drop-type dissipators
.
Flow Measurement and Instrumentation
54
,
298
306
.
https://doi.org/10.1016/j.flowmeasinst.2016.11.002
.
Liu
S. I.
Chen
J. Y.
Hong
Y. M.
Huang
H. S.
Raikar
R. V.
2014
Impact characteristics of free over-fall in pool zone with upstream bed slope
.
Journal of Marine Science and Technology (Taiwan)
22
(
4
),
476
486
.
https://doi.org/10.6119/JMST-013-0604-1
.
Mahmoud
M. I.
Ahmed
S. S.
Al-Fahal
A. S.
2013
Effect of different shapes of holes on energy dissipation through perpendicular screen
.
Journal of Environmental Studies
12
,
29
37
.
Mahtabi
G.
Chaplot
B.
Azamathulla
H. M.
Pal
M.
2020
Classification of hydraulic jump in rough beds
.
Water
12
(
8
),
2249
.
Moradinejad
A.
Saneie
M.
Ghaderi
A.
Zamanieh Shahri
S. M.
2019
Experimental study of flow pattern and sediment behavior near the intake structures using the spur dike and skimming wall
.
Applied Water Science
9
(
8
).
https://doi.org/10.1007/s13201-019-1069-7
.
Rajaratnam
N.
Chamani
M. R.
1995
Energy loss at drops
.
Journal of Hydraulic Research
33
(
3
),
373
384
.
https://doi.org/10.1080/00221689509498578
.
Rajaratnam
N.
Hurtig
K. I.
2000
Screen-type energy dissipator for hydraulic structures
.
Journal of Hydraulic Engineering
126
(
4
),
310
312
.
https://doi.org/10.1061/(ASCE)0733-9429(2000)126:4(310)
.
Rand
W.
1955
Flow geometry at straight drop spillways
.
Proceedings of the American Society of Civil Engineers
81
(
9
),
1
13
.
Rouse
H.
1936
Discharge characteristics of the free overfall: use of crest section as a control provides easy means of measuring discharge
.
Civil Engineering
6
(
4
),
257
260
.
Sadeghfam
S.
Akhtari
A. A.
Daneshfaraz
R.
Tayfur
G.
2014
Experimental investigation of screens as energy dissipaters in submerged hydraulic jump
.
Turkish Journal of Engineering and Environmental Sciences
38
(
2
),
126
138
.
https://doi.org/10.3906/muh-1401-15
.
Sadeghfam
S.
Daneshfaraz
R.
Khatibi
R.
Minaei
O.
2019
Experimental studies on scour of supercritical flow jets in upstream of screens and modelling scouring dimensions using artificial intelligence to combine multiple models (AIMM)
.
Journal of Hydroinformatics
21
(
5
),
893
907
.
https://doi.org/10.2166/hydro.2019.076
.
Sharif
M.
Kabiri-Samani
A.
2018
Flow regimes at grid drop-type dissipators caused by changes in tail-water depth
.
Journal of Hydraulic Research
56
(
4
),
505
516
.
https://doi.org/10.1080/00221686.2017.1395370
.
White
M. P.
1943
Discussion of moore
.
Tran ASCE
108
,
1361
1364
.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).