Water is a valuable resource and an elixir of life. It is intimately linked to living standards around the world. Reducing water stress and conserving the resource is vital. It is the need of the hour to ameliorate conventional water resources systems to monitor water quantity and quality parameters continuously in real-time. Smart solutions play an important role in monitoring system parameters and making on-site measurements. This paper focuses on Smart Water Grid, an ingenious way to monitor and preserve the quantity and quality parameters in real-time by deploying remote sensors in the water distribution system. It presents a review of various sensors deployed, networking protocols used and cloud platforms employed in monitoring the water distribution system. The suitable networking protocols for the water distribution systems are suggested by analyzing various smart solutions. It also proposes an architecture for an IoT-based system to monitor residual chlorine concentration in the water distribution system. Smart Water Grid using Wireless Sensor Networks and the Internet of Things enables the monitoring of on-site conditions and generates alerts during abnormal conditions. It can enhance timely decision-making which will help in managing valuable water resources more efficiently.

  • Conventional methods of water sampling are time- and labour-consuming. Information and communication technology plays a significant role in monitoring WDS.

  • SWG is useful for monitoring on-site water quantity and quality parameters continuously.

  • Various sensors, networking protocols and cloud platforms used in monitoring WDS are reviewed, and a new methodology for monitoring residual chlorine concentration using IoT is suggested.

Graphical Abstract

Graphical Abstract

Life does not exist without water. Nowadays, water is used not only for survival consumption; it is also used as a resource of luxury and comfort. As a result, water scarcity increases. National Intelligence Council (2012) reported that by the year 2025, most countries will become water-stressed. Apart from the scarce availability in terms of quantity, water quality has also become a concern in recent decades.

Disease and Risk Report (2012) of the World Health Organization (WHO) highlighted that diarrhea is the root cause of the deaths of approximately 1.5 million people every year. Slackness in the implementation of pollution control laws often results in a discharge of untreated effluents from domestic and industrial emissions into water bodies (Edokpayi et al. 2017). It is important to have clean and potable water to avoid countless diseases and to create a healthy living environment.

The Water Distribution System (WDS) is the main mode of water supply for urban communities. A reliable water supply in terms of quantity and quality is significant in this urbanized world. Conventional methods to measure water quality parameters are time-consuming and do not offer real-time detection of water quality (Ahmed et al. 2020). It is necessary to monitor the on-site conditions of WDS. Information and communication technology play a significant role in monitoring and managing the WDS in real time (Gautam et al. 2020). To overcome the defects of the conventional analysis and to monitor the WDS in real-time, the Smart Water Grid (SWG) is developed. The SWG is structured to monitor and control the water consumption, leaks and water quality changes in a WDS. Smart water quality monitoring is a cost-effective and efficient system in monitoring water quality parameters (Pasika & Gandla 2020).

This paper presents a review of earlier literature related to implementation of smart technologies in WDS. The review focuses on the application and developments of Wireless Sensor Networks (WSN) and the Internet of Things (IoT) in monitoring water quantity and quality parameters in WDS. The review summarizes the focus of the studies, sensors deployed and networking protocols used for WSN. In addition to this, the cloud platforms that are used are also reviewed for IoT. The main focus here is given to networking protocols since the suitability and performance of the smart monitoring system in terms of power consumption, data transmission range and data transmission rate are influenced by it. As an outcome, a new methodology to monitor the quality of water in the WDS in a smart way using the Internet of Things (IoT) is also suggested in this paper.

The conventional water quality measurement method requires sample collection from the source, conveyance, preservation and lab analysis. This method is time- and labour-consuming and the accuracy of the results is doubtful compared with on-site measurements. It is associated with two significant issues. (i) Most water bodies change quality parameters often with time and space. (ii) During transportation and preservation the samples can react with the new environment, which can alter the physical, chemical and biological characteristics. The biochemical alterations by the microorganisms can modify the concentrations of dissolved oxygen, carbon dioxide and organic compounds; subsequently they may alter the pH, chemical solubility and several other parameters (Horne & Goldman 1994). Thus, there is a need for reliable practices to represent the on-site conditions of water quality.

Monitoring the water quality is one of the important steps performed in developing and managing water resources. It is essential to go for advanced solutions to overcome the problems associated with the conventional water quality monitoring. One such solution is continuous real-time monitoring. It can provide a better insight into water quality issues and the factors affecting quality. Also, it reduces the time, cost and workforce associated with the conventional analysis. The real-time monitoring of water is required to make decisions regarding safe water supply, water treatment, regulatory problems, recreational purposes and public safety (Hirsch 2014).

Natural disasters, water terrorism and other such emergencies can affect the health of water resources (Gleick 2006). The pH, turbidity, dissolved oxygen, residual chlorine, Total Dissolved Solids (TDS) and microbial contamination are the key parameters to be monitored. Most water resources systems have now established several methods to collect continuous and real-time data about the supply and water quality. Smart water management solutions are gaining importance with the rapid development in communication technologies, primarily Wireless Sensor Networks (WSN) and IoT.

WSN is a technology used in IoT, it contains a large number of sensors but they cannot directly send the information to the internet. If it is required to send data to the internet, then a router device or sink node is necessary. In an IoT system, the internet is an inherent component. Sensors can directly send information to the internet and store them in the cloud where storage, analytics and live visualization can be done. An IoT system involves hardware, software, networking protocols and cloud technologies to gather, store and analyze the data to make better decisions.

An integrated set of products, solutions and systems that enable the WDS to remotely and continuously monitor, diagnose and optimize all aspects of WDS is known as Smart Water Grid (Savic 2015). It helps in prioritizing and managing maintenance issues. SWG uses WSN and IoT with different electronic communication devices and routing protocols to deliver real-time data continuously from several locations. The collected data is useful in optimizing the WDS performance. It also provides meaningful information to the end-users. Thus, SWG brings a considerable improvement by presenting the real-time data up front and makes the authorities analyze the data and take necessary actions in a short time. It is not only useful for significantly improving the age-old WDS but also for solving global water stress (Joshi 2020).

Sensor placement plays an important role in an SWG. The widely used objective functions for optimal sensor placements are to minimize the time of detection, minimize the impact, the size of the population exposed and the extent of the damage (Ostfeld et al. 2008; Adedoja et al. 2019). Optimal sensor placement helps in better diagnosis of WDS (Nejjari et al. 2015). To improve the system efficacy and lower the cost, appropriate optimization algorithms must be used (Krause et al. 2008).

Wu et al. (2007) attempted to identify suitable monitoring locations to detect contaminant intrusion within the WDS. The authors highlighted three possible monitoring points: (i) at the outlet of the treatment plant; (ii) vulnerable areas like the end region of branched pipes and corroded regions; and (iii) representative monitoring points (locations that exactly reflect the water quality as much as possible in the WDS). The Water Age Index (WAI) was used as a surrogate measure to identify the representative monitoring points.

Yazdekhasti et al. (2020) assessed the Life-Cycle Cost (LCC) and energy utilization of sensors deployed to monitor and detect leaks in WDS. The Leak Detection Index (LDI) was used to assess the cost and energy consumption sensitivity to data sampling rate, data transmission rate and sensor spacing. It was discovered that power utilization and LCC are profoundly sensitive to the sensor spacing; the larger the node distance, the more modest is the utilization and vice-versa. When the sensor spacing is less, more sensing nodes are required to sense which will increase the initial investment and power consumption (Halgamuge et al. 2009). This will escalate the operation and maintenance cost to a higher level. When the sensors are spaced at a very large distance, the accuracy of data will decrease. Thus, it is necessary to optimize the sensor placement to maximize the performance and to minimize the overall cost and power consumption.

The architecture of a typical WSN is shown in Figure 1. The sensors scattered in a field (source nodes) sense, collect and route the information to the sink node. The sink node forwards the sensory data to the end-user or client via the internet using networking or communication technologies. A WSN covers many spatially distributed, battery-operated, embedded devices that are networked to collect, process and transfer the sensory data to the users.

Figure 1

Architecture of Wireless Sensor Networks.

Figure 1

Architecture of Wireless Sensor Networks.

Close modal

Several technologies like Radio Frequency Identification (RFID), Global System for Mobile communication (GSM), General Packet Radio Service (GPRS), Zigbee, Long-Range wide-area network (LoRa), Bluetooth, Low Power Wireless Personal Area Networks (LoWPAN) and Wi-Fi systems using 2G, 3G and 4G networks have been used to transfer the sensory data in WDS. A summary of earlier studies on WDS using WSN is presented in Table 1. The summary includes the focus of the study, sensors used, networking protocols employed and the key inferences.

Table 1

Summary of earlier studies on smart monitoring of WDS using WSN

Authors & yearFocus of the studySensorsNetworking protocolRemarks/Key points
Stoianov et al. (2007)  Detect and locate the leaks and bursts Pressure and pH sensors Bluetooth and GPRS Duty cycling of sensor nodes was adopted for power saving. 
Christodoulou et al. (2010)  Detect and localize the leaks Pressure, flow, humidity, acoustic, soil moisture and noise sensors GPRS Duty cycling was adopted for power saving. Stargate communication gateway was used to control the duty cycling of sensors. A decision support system was used for detecting and localizing leaks in WDS. 
Whittle et al. (2010)  Hydraulic parameters (flow rate and pressure), water quality and acoustic parameters Pressure, flow, pH and acoustic sensors Wi-Fi Wi-Fi is suitable for short-range communication. Decision support tools and software were used for simulation and optimization of water demand zones. Acoustic parameters are used for leak detection. 
Ediriweera & Marshall (2010)  Hydraulic parameters Pressure and flow sensors GPRS and GSM GPRS and GSM are suitable for high-rate data transmission. Notifications and alert messages were sent to the consumers during anomalous events. 
Alkandari et al. (2012)  Water quality parameters pH, dissolved oxygen and temperature sensors Zigbee+802.11 Ethernet radio Zigbee is a low-cost and low power consumption protocol. Long-range data transmission can be achieved by coupling Zigbee with Ethernet. 
Offiong et al. (2014),a, Lambrou et al. (2014),a, Cloete et al. (2016) a, Priya et al. (2017) a Water quality parameters pH, dissolved oxygen, temperature, turbidity, electrical conductivity and oxidation reduction potential sensors Zigbee Zigbee is suitable for short-range communication. 
Almazyad et al. (2014)  Detect and localize leaks RFID tags RFID Power conservation was achieved by duty cycling. 
Kruger et al. (2015)  Water consumption Flow meters 6LoWPAN+Wi-Fi Low power consumption, low cost, resolves co-existence problems occurring between network layers. 
Public Utilities Board Singapore (2016)  Monitor the flow, quality and leak Flow meters, pressure, pH, turbidity and temperature sensors Radio frequency, 2G, 3G, Wi-Fi Low cost, low power consumption and high data transmission. Alert messages were sent to the consumers in case of abnormalities. 
Authors & yearFocus of the studySensorsNetworking protocolRemarks/Key points
Stoianov et al. (2007)  Detect and locate the leaks and bursts Pressure and pH sensors Bluetooth and GPRS Duty cycling of sensor nodes was adopted for power saving. 
Christodoulou et al. (2010)  Detect and localize the leaks Pressure, flow, humidity, acoustic, soil moisture and noise sensors GPRS Duty cycling was adopted for power saving. Stargate communication gateway was used to control the duty cycling of sensors. A decision support system was used for detecting and localizing leaks in WDS. 
Whittle et al. (2010)  Hydraulic parameters (flow rate and pressure), water quality and acoustic parameters Pressure, flow, pH and acoustic sensors Wi-Fi Wi-Fi is suitable for short-range communication. Decision support tools and software were used for simulation and optimization of water demand zones. Acoustic parameters are used for leak detection. 
Ediriweera & Marshall (2010)  Hydraulic parameters Pressure and flow sensors GPRS and GSM GPRS and GSM are suitable for high-rate data transmission. Notifications and alert messages were sent to the consumers during anomalous events. 
Alkandari et al. (2012)  Water quality parameters pH, dissolved oxygen and temperature sensors Zigbee+802.11 Ethernet radio Zigbee is a low-cost and low power consumption protocol. Long-range data transmission can be achieved by coupling Zigbee with Ethernet. 
Offiong et al. (2014),a, Lambrou et al. (2014),a, Cloete et al. (2016) a, Priya et al. (2017) a Water quality parameters pH, dissolved oxygen, temperature, turbidity, electrical conductivity and oxidation reduction potential sensors Zigbee Zigbee is suitable for short-range communication. 
Almazyad et al. (2014)  Detect and localize leaks RFID tags RFID Power conservation was achieved by duty cycling. 
Kruger et al. (2015)  Water consumption Flow meters 6LoWPAN+Wi-Fi Low power consumption, low cost, resolves co-existence problems occurring between network layers. 
Public Utilities Board Singapore (2016)  Monitor the flow, quality and leak Flow meters, pressure, pH, turbidity and temperature sensors Radio frequency, 2G, 3G, Wi-Fi Low cost, low power consumption and high data transmission. Alert messages were sent to the consumers in case of abnormalities. 

aAll the four studies focused on same water quality parameters and used the same networking protocol (Zigbee).

IoT is a remarkable progression in the area of internet technology. It is a prominent research topic in the fields of engineering, science and technology due to its vast application as well as for its amalgamation of various communications and embedded technology in its architecture. An IoT network connects physical devices that share and retrieve electronic information. It includes a wide variety of smart devices, ranging from tracking information from the human body to the production of large industrial machines (Kenton 2020).

The objective of implementing IoT is to obtain real-time useful information on the ground with minimal human intervention. IoT extends its solutions to various application domains such as home automation, agriculture, infrastructure, transportation, space, and healthcare industries, water systems and military works. Thereby, it gradually transforms them into smart systems. Here, the term ‘smart’ refers to the automation and remote operation of devices that can be accessed from anywhere with mobile phones or computers using an internet connection. The architecture of a typical IoT is shown in Figure 2. It consists of sensors that communicate to the cloud through gateway devices. A gateway acts as a bridge between sensors and cloud platforms. It can communicate with sensors/devices over different networking protocols and then the data is sent to the cloud. Once the data enters the cloud, analysis and processing take place. Finally, it can be sent to the intended user/client.

Figure 2

Architecture of Internet of Things.

Figure 2

Architecture of Internet of Things.

Close modal

Sensors which are deployed in the physical devices are connected to an IoT platform: (i) to collect the data; (ii) to process and analyze the data; and (iii) to support the specific application services. These IoT platforms can precisely extract useful information. The information can be used to detect patterns and problems, generate alerts and make recommendations (Clark 2016). The most common four-level IoT architecture includes: (i) Perception Layer; (ii) Network Layer; (iii) Support Layer; and (iv) Application Layer as shown in Figure 3.

Figure 3

Layers of Internet of Things.

Figure 3

Layers of Internet of Things.

Close modal

Burhan et al. (2018) described the architecture of IoT elaborately. (i) The ground layer is the perception or discernment layer. It is the actual physical layer and has a heterogeneous category of sensors for detecting actual conditions of the environment. For sustainable energy management, the perception layer can be coupled with solar panels, and piezoelectric, electromagnetic and thermoelectric harvesting techniques (Radhakrishnan & Wu 2018). (ii) The network layer is a transport layer, which transports the acquired data from source nodes to sink nodes using wireless communications. The network layer uses communication and networking technologies such as Wi-Fi, Bluetooth, LoRa, Zigbee, etc. for data transmission. (iii) The support layer is a data processing layer that stores, analyses and processes massive quantities of data (big data) received from the transport layer. Cloud computing is primarily used to manage the data in a centralized manner. (iv) The application layer is the topmost layer and it describes all IoT-related applications. It is the connection between end-to-end IoT devices. This application layer is the service layer that is answerable for conveying application-specific services to the clients.

A summary of earlier studies on WDS using IoT is presented in Table 2. The details on the focus of the study, various sensors deployed, networking protocols along with IoT cloud platform used and key inferences are included in the summary.

Table 2

Summary of earlier studies on smart monitoring of WDS using IoT

Authors & yearFocus of the studySensorsNetworking protocol+Cloud platformRemarks/Key points
Verma et al. (2015)  Monitoring the tank water level and the volume of water available for supply Ultrasonic water level sensor Sub-GigaHertz radio network+Google App Engine Duty cycling was adopted for power saving. The cloud platform provides an online data visualization in graphical patterns and performs data analytics. 
Anjana et al. (2015)  Monitoring the water supply and water quality and controlling wastage by deploying smart water metering system Flow meters, pH and oxidation reduction potential sensors 6LoWPAN+MYSQL data+Visual Studio Express 2013 Daily and monthly water consumption was monitored. Tracks and monitors the water quality parameters. In the case of variations in the supply, SMS alerts were sent to the consumers. Automatic leak detection helped to localize the leaks and control the flow. The system was used to identify overconsumption and wastage. 
Shahanas & Sivakumar (2016) a, Geetha & Gouthami (2017) a Monitoring the tank water level and water quality parameters Ultrasonic water level, pH, conductivity, turbidity and temperature sensors Wi-Fi+Ubidots Low cost and low power consumption. Suitable for short-range communication. Consumer alert messages were sent in the case of any contamination events in the WDS.
Daily and weekly average water consumption was monitored. The data was used to identify the consumption rate and for demand forecasting. 
Shirode et al. (2018) a, Nikhil et al. (2018) a Wi-Fi+Thingspeak 
Devasena et al. (2019) a, Gautam et al. (2020) a Wi-Fi+cloud platform not mentioned 
Fuentes & Mauricio (2020) a Wi-Fi+IBM cloudant 
Saravanan et al. (2018) a Monitoring the hydraulic and water quality parameters Flow and temperature sensors GPRS, GSM, SCADA system+cloud platform not mentioned Live data streaming and analysis heading to better decisions. Alerts were given in the case of abnormalities in supply. 
Srihari (2018) b Control water crisis Flow and pH sensors; water control valve Ethernet+MQTT protocol+cloud platform not mentioned IoT-based WDS ensure equity in water distribution. Alert notifications were sent to the consumers in the case of abnormal events in the system and supply. 
Das & Jain (2017) b, Rajurkar et al. (2017) b Monitoring the rate of flow and water consumption, controlling wastage Flow sensor Zigbee+Thingspeak Zigbee is suitable for short-range communication. Consumption data was sensed for all seasons and used to forecast the water demand. Current and average water consumption were measured. Alert messages were sent to the consumers in the case of overconsumption. 
Alves et al. (2019) b Zigbee+Firebase Android Studio 
Chinnusamy et al. (2018) c Monitoring the tank water level, rate of flow and water quality parameters Ultrasonic water level, flow, pH, dissolved oxygen, turbidity and temperature sensors LoRa+Graffna LoRa is suitable for long-range data communication. It is a low power consumption protocol. Control valve is to minimize overuse and wastage. Alert messages were generated for water levels and pump operation changes (on/off). 
Simitha & Subodh Raj (2019) c LoRa+Wi-Fi+Thingspeak 
Glória et al. (2020) c LoRa+Wi-Fi+cloud platform not mentioned 
Authors & yearFocus of the studySensorsNetworking protocol+Cloud platformRemarks/Key points
Verma et al. (2015)  Monitoring the tank water level and the volume of water available for supply Ultrasonic water level sensor Sub-GigaHertz radio network+Google App Engine Duty cycling was adopted for power saving. The cloud platform provides an online data visualization in graphical patterns and performs data analytics. 
Anjana et al. (2015)  Monitoring the water supply and water quality and controlling wastage by deploying smart water metering system Flow meters, pH and oxidation reduction potential sensors 6LoWPAN+MYSQL data+Visual Studio Express 2013 Daily and monthly water consumption was monitored. Tracks and monitors the water quality parameters. In the case of variations in the supply, SMS alerts were sent to the consumers. Automatic leak detection helped to localize the leaks and control the flow. The system was used to identify overconsumption and wastage. 
Shahanas & Sivakumar (2016) a, Geetha & Gouthami (2017) a Monitoring the tank water level and water quality parameters Ultrasonic water level, pH, conductivity, turbidity and temperature sensors Wi-Fi+Ubidots Low cost and low power consumption. Suitable for short-range communication. Consumer alert messages were sent in the case of any contamination events in the WDS.
Daily and weekly average water consumption was monitored. The data was used to identify the consumption rate and for demand forecasting. 
Shirode et al. (2018) a, Nikhil et al. (2018) a Wi-Fi+Thingspeak 
Devasena et al. (2019) a, Gautam et al. (2020) a Wi-Fi+cloud platform not mentioned 
Fuentes & Mauricio (2020) a Wi-Fi+IBM cloudant 
Saravanan et al. (2018) a Monitoring the hydraulic and water quality parameters Flow and temperature sensors GPRS, GSM, SCADA system+cloud platform not mentioned Live data streaming and analysis heading to better decisions. Alerts were given in the case of abnormalities in supply. 
Srihari (2018) b Control water crisis Flow and pH sensors; water control valve Ethernet+MQTT protocol+cloud platform not mentioned IoT-based WDS ensure equity in water distribution. Alert notifications were sent to the consumers in the case of abnormal events in the system and supply. 
Das & Jain (2017) b, Rajurkar et al. (2017) b Monitoring the rate of flow and water consumption, controlling wastage Flow sensor Zigbee+Thingspeak Zigbee is suitable for short-range communication. Consumption data was sensed for all seasons and used to forecast the water demand. Current and average water consumption were measured. Alert messages were sent to the consumers in the case of overconsumption. 
Alves et al. (2019) b Zigbee+Firebase Android Studio 
Chinnusamy et al. (2018) c Monitoring the tank water level, rate of flow and water quality parameters Ultrasonic water level, flow, pH, dissolved oxygen, turbidity and temperature sensors LoRa+Graffna LoRa is suitable for long-range data communication. It is a low power consumption protocol. Control valve is to minimize overuse and wastage. Alert messages were generated for water levels and pump operation changes (on/off). 
Simitha & Subodh Raj (2019) c LoRa+Wi-Fi+Thingspeak 
Glória et al. (2020) c LoRa+Wi-Fi+cloud platform not mentioned 

Italic font is used to show the cloud platform.

a,b,cFocus of the studies, sensors used and communication protocol used are the same but cloud platforms are different.

The use of WSN and IoT in monitoring water quantity and quality parameters in WDS is reviewed in this paper. It is observed that a few parameters need more attention. One such key parameter that has to be monitored in real-time in WDS is residual chlorine concentration. The core reason behind which the residual chlorine parameter is not taken for real-time monitoring is the requirement of a high initial investment. Residual chlorine, also called free chlorine, is the minimal quantity of chlorine retained in water after it is applied for a certain period or contact time (Safe Water System, CDC 2014). The residual chlorine constitutes an important safeguard for water against microbial contamination during transportation from treatment plants to consumer points. It is correlated with the absence of microbes and is a gauge for the potability of the water (Safe Water System, CDC 2014).

A few studies have been carried out in continuous monitoring of residual chlorine concentration using amperometric, spectrophotometric, colorimetric and potentiometric sensors in a controlled environment (Banna et al. 2014; Yaroshenko et al. 2020). These sensors are useful in real-time monitoring of the residual chlorine in water but cannot be incorporated in IoT technology. Perelman & Ostfeld (2013) proposed the use of mobile sensors to monitor residual chlorine concentration to prevent contamination events and to increase system security in WDS. It was reported that inclusion of fixed sensors in addition to the mobile sensors was necessary for accurate results. Zidan et al. (2018) developed a prototype to monitor and control chlorine at the desired level in a water treatment plant in a controlled lab environment. An ultrasonic level sensor and residual chlorine sensor in conjunction with an Arduino controller measured the tank water level, tank chlorine level and chlorine concentration in the measuring station. The dosing pump was controlled based on the chlorine concentration in the measuring station. The sensed data received by the gateway devices were transmitted to the cloud using Wi-Fi technology. MongoDB, a web-based cloud application, was used to analyze and process the chlorine data and to alert users directly in the case of variations in chlorine concentrations, system errors and abnormal water quality conditions. However, real-time monitoring of residual chlorine over a large-scale WDS is yet to be explored.

In this paper, an IoT-based monitoring of residual chlorine in WDS is proposed and the architecture is shown in Figure 4. For measuring residual chlorine, flow-through-type chlorine sensors are preferred where the sensors can directly be immersed in water. They can measure the residual chlorine in a range of 0 to 20 mg/L, the pressure range is up to 1 bar and the resolution can be 0.01 mg/L with an accuracy of ±2%. This type of sensor can be directly connected to microcontrollers and can be easily deployed in any WDS.

Figure 4

Architecture of the proposed IoT-based residual chlorine monitoring in WDS.

Figure 4

Architecture of the proposed IoT-based residual chlorine monitoring in WDS.

Close modal

Remote monitoring of residual chlorine in WDS demands low data rate and long-range data communication. Thus, LoRa technology can be an ideal networking technology to monitor the residual chlorine in WDS stretching over several kilometres. The cloud platform has to be decided depending upon the client services provided by the service providers. The profit of monitoring residual chlorine in WDS using IoT outweighs its cost by providing benefits like public health and acting as an early warning system. The day and night continuous monitoring of residual chlorine in the system is possible and it can be viewed as graphical charts and tables using application services.

From the detailed review, it is observed that the WSN and IoT narrowed the use of long-distance wiring and human expertise. The life-cycle cost of a sensor depends on the optimal placement of the sensor. The larger the sensors spacing, the less is the power consumption. Closer spacing of sensors increases the power consumption and thereby increases the operation cost besides the capital cost. Optimal sensor placement is a key factor in deploying WSN and IoT technology; it helps in stimulating the performance of WDS.

Communication technologies like Wi-Fi, Zigbee and LoRa have been mostly preferred in real-time monitoring. Wi-Fi technology is preferred in water quality monitoring due to its low cost, high speed, wide coverage area, common standards and easy interfacing between hardware and software components. However, it has a few drawbacks, such as high power consumption, low coverage area and the requirement of a central access point. It is noted that the Zigbee protocol has been adopted in several cases of water quality monitoring, owing to its prime characteristics such as low power consumption, cost-effectiveness, energy efficiency, reliability and flexibility. It can be concluded that Zigbee is preferred for real-time monitoring of WDS which demands low data rates and short-range communication. LoRa technology is also preferred for its low cost, low power, wide-coverage, long-range communication and security. LoRa enables long-range communication links extended to several kilometres with high sensitivity and computing anti-interference. Thus, it is suggested that this LoRa communication is a better option for remote monitoring of WDS that runs several kilometres and covers a wide area.

In this paper, earlier studies on monitoring, diagnosing and controlling the water distribution system remotely and continuously using Wireless Sensor Networks and the Internet of Things were reviewed. The use of WSN and IoT is a low-cost solution, reduces human intervention and also generates greater benefits for society. In future, integration of information and communication technologies for water resources monitoring and management will be inevitable. It is noted that power savings and performance enhancement can be achieved by optimally placing the sensors.

It is concluded that the Zigbee communication protocol can be used for short-range monitoring and LoRa for long-range monitoring. It is proposed that this LoRa communication is suitable for remote monitoring of residual chlorine concentration in WDS. The WSN and IoT-based Smart Water Grid assists in making evidence-based decisions on managing water quantity and quality. SWG is a promising solution with the ability to provide extended benefits to utilities and users through remotely and continuously monitoring and managing the system using data-driven insights. Smart Water Grid can provide the water authorities with propitious solutions in managing precious resources more effectively and economically.

All relevant data are included in the paper or its Supplementary Information.

Adedoja
O. S.
,
Hamam
Y.
,
Khalaf
B.
&
Sadiku
R.
2019
A state-of-the-art review of an optimal sensor placement for contaminant warning system in a water distribution network
.
Urban Water Journal
15
(
10
),
985
1000
.
https://doi.org/10.1080/1573062X.2019.1597378
.
Ahmed
U.
,
Mumtaz
R.
,
Anwar
H.
,
Mumtaz
S.
&
Qamar
A. M.
2020
Water quality monitoring, from conventional to emerging technologies
.
Water Supply
20
(
1
),
28
45
.
https://doi.org/10.2166/ws.2019.144
.
Alkandari
A.
,
Alnasheet
M.
,
Alabduljader
Y.
&
Moein
S. M.
2012
Water monitoring system using wireless sensor network (WSN): case study of Kuwait beaches
. In:
2012 Second International Conference on Digital Information Processing and Communications (ICDIPC)
,
IEEE, Piscataway, NJ, USA
, pp.
10
15
.
doi:10.1109/ICDIPC.2012.6257270
.
Almazyad
A. S.
,
Seddiq
Y. M.
,
Alotaibi
A. M.
,
Al-Nasheri
A. Y.
,
Ben Saleh
M. S.
,
Obeid
A. M.
&
Qasim
S. M.
2014
A proposed scalable design and simulation of wireless sensor network-based long-distance water pipeline leakage monitoring system
.
Sensors
14
(
2
),
3557
3577
.
https://doi.org/10.3390/s140203557
.
Alves
A. J. R.
,
Manera
L. T.
&
Campos
M. V.
2019
Low-cost wireless sensor network applied to real-time monitoring and control of water consumption in residences
.
Ambiente e Água – An Interdisciplinary Journal of Applied Science
14
(
6
),
1
10
.
doi:10.4136/ambi-agua.2407
.
Anjana
S.
,
Sahana
M. N.
,
Ankith
S.
,
Natarajan
K.
,
Shobha
K. R.
&
Paventhan
A.
2015
An IoT-based 6LoWPAN enabled experiment for water management
. In:
2015 IEEE International Conference on Advanced Networks and Telecommunications Systems (ANTS)
,
15–18 December, Kolkata
,
India
.
doi:10.1109/ANTS.2015.7413654
.
Banna
H. M.
,
Imran
S.
,
Francisque
A.
,
Najjaran
H.
,
Sadiq
R.
,
Rodriguez
M.
&
Hoorfar
M.
2014
Online drinking water quality monitoring: review on available and emerging technologies
.
Critical Reviews in Environmental Science and Technology
44
(
12
),
1370
1421
.
https://doi.org/10.1080/10643389.2013.781936
.
Burhan
M.
,
Rehman
R. A.
,
Khan
B.
&
Kim
B.-S.
2018
IoT elements, layered architectures and security issues: a comprehensive survey
.
Sensors
18
(
9
),
2796
.
https://doi.org/10.3390/s18092796
.
Chinnusamy
S.
,
Mohandoss
P.
,
Paul
P.
,
Rohit
R.
,
Murali
N.
,
Bhallamudi
S. M.
,
Narasimhan
S.
&
Narasimhan
S.
2018
IoT enabled monitoring and control of water distribution network
. In:
1st International WDSA/CCWI 2018 Joint Conference
,
Kingston, Ontario, Canada
.
Christodoulou
S.
,
Agathokleous
A.
,
Kounoudes
A.
&
Milis
M.
2010
Wireless sensor networks for water loss detection
.
Journal of European Water
30
,
41
48
.
Clark
J.
2016
What is the Internet of Things (IoT)? IBM Business Operations Blog (17 November)
.
Cloete
N. A.
,
Malekian
R.
&
Nair
L.
2016
Design of smart sensors for real-time water quality monitoring
.
IEEE Access
4
,
3975
3990
.
doi: 10.1109/ACCESS.2016.2592958
.
Das
B.
&
Jain
P. C.
2017
Real-time water quality monitoring system using Internet of Things
. In:
2017 International Conference on Computer, Communications and Electronics (Comptelix)
,
IEEE, Piscataway, NJ, USA
, pp.
78
82
.
doi:10.1109/COMPTELIX.2017.8003942
.
Devasena
D.
,
Ramya
R.
,
Dharshan
Y.
,
Vivek
S.
&
Darshan
T.
2019
IoT based water distribution system
.
Journal of Engineering and Advanced Technology
8
(
6
),
132
135
.
doi:10.35940/ijeat.D6295.088619
.
Ediriweera
D. D.
&
Marshall
I. W.
2010
Monitoring water distribution systems: understanding and managing sensor networks
.
Drinking Water Engineering and Science
3
(
2
),
107
113
.
doi:10.5194/dwes-3-107-2010
.
Edokpayi
J. N.
,
Odiyo
J. O.
&
Durowoju
O. S.
2017
Impact of wastewater on surface water quality in developing countries: a case study of South Africa
. In:
Water Quality
(
H. Tutu & B. P. Grover, eds
),
Intech
,
Rijeka, Croatia
, pp.
401
406
.
doi:10.5772/66561
.
Fuentes
H.
&
Mauricio
D.
2020
Smart water consumption measurement system for houses using IoT and cloud computing
.
Environmental Monitoring Assessment
192
,
602
.
doi:10.1007/s10661-020-08535-4
.
Gautam
J.
,
Chakrabarti
A.
,
Agarwal
S.
,
Singh
A.
,
Gupta
S.
&
Singh
J.
2020
Monitoring and forecasting water consumption and detecting leakage using an IoT system
.
Water Supply
20
(
3
),
1103
1113
.
https://doi.org/10.2166/ws.2020.035
.
Geetha
S.
&
Gouthami
S.
2017
Internet of things enabled real time water quality monitoring system
.
Smart Water
2
,
1
.
doi:10.1186/s40713-017-0005-y
.
Gleick
P. H.
2006
Water and terrorism
.
Water Policy
8
(
6
),
481
503
.
https://doi.org/10.2166/wp.2006.035
.
Glória
A.
,
Dionisio
C.
,
Simões
G.
,
Cardoso
J.
&
Sebastião
P.
2020
Water management for sustainable irrigation systems using Internet-of-Things
.
Sensors
20
(
5
),
1402
.
https://doi.org/10.3390/s20051402
.
Halgamuge
M. N.
,
Zukerman
M.
,
Kotagiri
R.
&
Vu
H. L.
2009
An estimation of sensor energy consumption
.
Progress in Electromagnetics Research B
12
,
259
295
.
doi:10.2528/PIERB08122303
.
Hirsch
R.
2014
Why continuous and real time? USGS WaterQualityWatch. Available from: https://waterwatch.usgs.gov/wqwatch/faq?faq_id=3
.
Horne
A. J.
&
Goldman
C. R.
1994
Introduction to the chemistry of natural waters
. In:
Limnology
,
(A. J. Horne & C. R. Goldman)
2nd edn,
McGraw-Hill
,
New York, USA
, pp.
106
114
.
Joshi
N.
2020
Smart water grids: The future of water distribution and management. Technology for You (3 January)
.
Kenton
W.
2020
Internet of Things (IoT)
.
Krause
A.
,
Singh
A.
&
Guestrin
C.
2008
Near-optimal sensor placements in Gaussian processes: theory, efficient algorithms and empirical studies
.
Journal of Machine Learning Research
9
,
235
284
.
Kruger
C. P.
,
Abu-Mahfouz
A. M.
&
Hancke
G. P.
2015
Rapid prototyping of a wireless sensor network gateway for the internet of things using off-the-shelf components
. In:
2015 IEEE International Conference on Industrial Technology (ICIT)
,
IEEE, Piscataway, NJ, USA
, pp.
1926
1931
.
doi:10.1109/ICIT.2015.7125378
.
Lambrou
T. P.
,
Anastasiou
C. C.
,
Panayiotou
C. G.
&
Polycarpou
M. M.
2014
A low-cost sensor network for real-time monitoring and contamination detection in drinking water distribution systems
.
Sensors
14
(
8
),
2765
2772
.
doi:10.1109/JSEN.2014.2316414
.
National Intelligence Council
2012
Global Water Security
,
Intelligence Community Assessment ICA 2012-08. Office of the Director of National Intelligence
,
Washington, DC, USA
.
Nejjari
F.
,
Sarrate
R.
&
Blesa
J.
2015
Optimal pressure sensor placement in water distribution networks minimizing leak location uncertainty
.
Procedia Engineering
119
,
953
962
.
doi:10.1016/j.proeng.2015.08.979
.
Nikhil
R.
,
Rajender
R.
,
Dushyantha
G. R.
,
Khadri
M. N. S.
&
Kalshetty
J. N.
2018
Smart water quality monitoring system using IoT environment
.
International Journal of Innovations in Engineering and Technology
10
(
4
),
74
78
.
Offiong
N. M.
,
Abdullahi
S. A.
,
Chile-Agada
B. U. N.
,
Raji-Lawal
H. Y.
&
Nweze
N. O.
2014
Real time monitoring of urban water systems for developing countries
.
IOSR Journal of Computer Engineering
16
(
3
),
11
14
.
doi:10.9790/0661-16321114
.
Ostfeld
A.
,
Uber
J. G.
,
Salomons
E.
,
Berry
J. W.
,
Hart
W. E.
,
Phillips
C. A.
,
Watson
J.-P.
,
Dorini
G.
,
Jonkergouw
P.
,
Kapelan
Z.
,
di Pierro
F.
,
Khu
S.-T.
,
Savic
D.
,
Eliades
D.
,
Polycarpou
M.
,
Ghimire
S. R.
,
Barkdoll
B. D.
,
Gueli
R.
,
Huang
J. J.
,
McBean
E. A.
,
James
W.
,
Krause
A.
,
Leskovec
J.
,
Isovitsch
S.
,
Xu
J.
,
Guestrin
C.
,
VanBriesen
J.
,
Small
M.
,
Fischbeck
P.
,
Preis
A.
,
Propato
M.
,
Piller
O.
,
Trachtman
G. B.
,
Wu
Z. Y.
&
Walski
T.
2008
Battle of the Water Sensor Networks (BWSN): a design challenge for engineers and algorithms
.
Journal of Water Resources Planning and Management
134
(
6
),
556
568
.
doi:10.1061/(ASCE)0733-9496(2008)134:6(556)
.
Pasika
S.
&
Gandla
S. T.
2020
Smart water quality monitoring system with cost-effective using IoT
.
Heliyon
6
(
7
),
E04096
.
https://doi.org/10.1016/j.heliyon.2020.e04096
.
Perelman
L.
&
Ostfeld
A.
2013
Operation of remote mobile sensors for security of drinking water distribution systems
.
Water Research
47
(
13
),
4217
4226
.
doi:10.1016/j.watres.2013.04.048
.
Priya
S. K.
,
Lakshmi
G. S.
&
Revathi
T.
2017
Design of smart sensors for real time drinking water quality monitoring and contamination detection in water distributed mains
.
International Journal of Engineering & Technology
7
(
1.1
),
47
51
.
doi:10.14419/ijet.v7i1.1.8921
.
Public Utilities Board Singapore
2016
Managing the water distribution network with a Smart Water Grid
.
Smart Water
1
,
4
.
doi:10.1186/s40713-016-0004-4
.
Radhakrishnan
V.
&
Wu
W.
2018
IoT technology for smart water system
. In:
2018 IEEE 20th International Conference on High Performance Computing and Communications
,
IEEE, Piscataway, NJ, USA, pp. 1491–1496
.
doi:10.1109/HPCC/SmartCity/DSS.2018.00246
.
Rajurkar
C.
,
Prabaharan
S. R. S.
&
Muthulakshmi
S.
2017
IoT based water management
. In:
2017 International Conference on Nextgen Electronic Technologies
:
Silicon to Software (ICNETS2), IEEE, Piscataway, NJ, USA
, pp.
255
259
.
doi:10.1109/ICNETS2.2017.8067943
.
Safe Water System
2014
Free Chlorine Testing. Centers for Disease Control and Prevention (CDC)
.
Saravanan
K.
,
Anusuya
E.
,
Kumar
R.
&
Son
L. H.
2018
Real-time water quality monitoring using Internet of Things in SCADA
.
Environmental Monitoring and Assessment
190
,
556
.
doi:10.1007/s10661-018-6914-x
.
Savic
D.
2015
Intelligent/Smart Water Systems
.
CIWEM
,
London, UK
.
Shahanas
K. M.
&
Sivakumar
P. B.
2016
Framework for a smart water management system in the context of smart city initiatives in India
.
Procedia Computer Science
92
,
142
147
.
https://doi.org/10.1016/j.procs.2016.07.337
.
Shirode
M.
,
Adaling
M.
,
Biradar
J.
&
Mate
T.
2018
Iot based water quality monitoring system
.
International Journal of Scientific Research in Computer Science, Engineering and Information Technology
3
(
1
),
1423
1428
.
Simitha
K. M.
&
Subodh Raj
M. S.
2019
IoT and WSN based water quality monitoring system
. In:
IEEE Proceedings of the Third International Conference on Electronics Communication and Aerospace Technology
,
IEEE, Piscataway, NJ, USA
, pp.
205
210
.
doi:10.1109/ICECA.2019.8821859
.
Srihari
M. M
, .
2018
Intelligent water distribution and management system using internet of things
. In:
Proceedings of the International Conference on Inventive Research in Computing Applications
(ICIRCA), IEEE, Piscataway, NJ, USA
, pp.
785
789
.
doi:10.1109/ICIRCA.2018.8597325
.
Stoianov
I.
,
Nachman
L.
,
Madden
S.
,
Tokmouline
T.
&
Csail
M.
2007
PIPENET: a wireless sensor network for pipeline monitoring
. In:
2007 6th International Symposium on Information Processing in Sensor Networks
,
IEEE, Piscataway, NJ, USA
, pp.
264
273
.
doi:10.1109/IPSN.2007.4379686
.
Verma
P.
,
Kumar
A.
,
Rathod
N.
,
Jain
P.
,
Mallikarjun
S.
,
Subramanian
R.
,
Amrutur
B.
,
Kumar
M. S. M.
&
Rajesh
S.
2015
Towards an IoT based water management system for a campus
. In:
2015 IEEE First International Smart Cities Conference (ISC2)
,
25–28 October
,
Guadalajara, Mexico
.
doi: 10.1109/ISC2.2015.7366152
.
Whittle
A. J.
,
Girod
L.
,
Preis
A.
,
Allen
M.
,
Lim
H. B.
,
Iqbal
M.
,
Srirangarajan
S.
,
Fu
C.
,
Wong
K. J.
&
Goldsmith
D.
2010
WaterWise@SG: a testbed for continuous monitoring of the water distribution system in Singapore
. In:
12th Annual Conference on Water Distribution Systems Analysis (WDSA)
(K. E. Lansey, C. Y. Choi, A. Ostfeld & I. L. Pepper, eds), ASCE, Reston, VA
,
USA
, pp.
1362
1378
.
https://doi.org/10.1061/41203(425)122
.
World Health Organization (WHO)
2012
Water Sanitation Hygiene. Diseases and risks
.
Wu
W.
,
Gao
J.
,
Zhao
M.
,
Qian
Z.
,
Hou
X. Q.
&
Han
Y.
2007
Assessing and optimizing online monitoring for securing the water distribution system
. In:
2007 IEEE International Conference on Networking, Sensing and Control
,
IEEE, Piscataway, NJ, USA
, pp.
350
355
.
doi:10.1109/ICNSC.2007.372804
.
Yaroshenko
I.
,
Kirsanov
D.
,
Marjanovic
M.
,
Lieberzeit
P. A.
,
Korostynska
O.
,
Mason
A.
,
Frau
I.
&
Legin
A.
2020
Real-time water quality monitoring with chemical sensors
.
Sensors
20
(
12
),
3432
.
https://doi.org/10.3390/s20123432
.
Yazdekhasti
S.
,
Piratia
K. R.
,
Sorber
J.
,
Atamturktur
S.
,
Khan
A.
&
Shukla
H.
2020
Sustainability analysis of a leakage-monitoring technique for water pipeline networks
.
Journal of Pipeline Systems Engineering and Practice
11
(
1
),
04019052
.
https://doi.org/10.1061/(ASCE)PS.1949-1204.0000425
.
Zidan
N.
,
Maree
M.
&
Samhan
S.
2018
An IoT based monitoring and controlling system for water chlorination treatment
. In:
Proceedings of the 2nd International Conference on Future Networks & Distributed Systems (ICFNDS'18)
,
ACM, New York, USA, article no. 31
.
https://doi.org/10.1145/3231053.3231084.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).