Safe drinking water is a fundamental requirement for human life. The deterioration of water quality primarily involves microbiological hazards, since most evident water-related health problems are the result of microbial contamination. The aim of this study was to evaluate the microbial contamination of drinking water from three sources: water vending machines (WVMs), soda fountains (SFs), and tap water (TW) in the Eastern Coachella Valley (ECV) using physico-chemical parameters, conventional cultivable methods, including IDEXX technology and molecular methods. A total of 72 samples were analyzed and results indicated heterotrophic plate counts (HPCs) bacteria in 20% of samples from WVMs, 25% of samples from SFs, 33.3% of TW samples, and 76% of swab samples. Results also demonstrated 20% of WVM, 88% of swab samples, 41% of SF, and 50% of TW samples had total coliforms. Our qPCR indicated the presence of genetic materials of all six selected microorganisms (Salmonella spp, Listeria monocytogenes, Pseudomonas aeruginosa, Campylobacter jejuni, Escherichia coli, Enterococcus faecalis) used as indicators of pathogenic microorganisms in water from WVMs, SFs, and TW, and were represented at different concentrations and predominance.

  • First study in the Eastern Coachella Valley to assess the water quality from soda fountains, water vending machines, swabs, and tap water.

  • This study reinforces the health risk of biofilms in water dispensers and the importance to develop surveillance and regulation that target water dispensers.

  • The study coupled physico-chemical parameters, DEXX Quanti-Trays, HPC, and qPCR.

Drinking water is vital to human existence, and its bacterial contamination poses a serious public health threat worldwide. Despite the continued efforts to maintain water safety, waterborne outbreaks are still reported globally (Ramírez-Castillo et al. 2015). While drinking water quality can deteriorate through contaminants, such as toxic chemicals and microbes during transport, storage, and handling, distribution lines and systems may also influence the quality of drinking water (Bitton 2005). Approximately 2 billion people globally are obligated to utilize contaminated drinking water with excreta, while 1.2 billion people lack basic drinking water services, and more than 829,000 people die each year from contaminated drinking water (World Health Organization (WHO) 2022). Although the quality of tap water (TW) in most high-income countries is stringently regulated and monitored, the demand for bottled and dispensed water has been on the rise worldwide (Hu et al. 2011; Patel et al. 2016; Praveena et al. 2018). The consumption of bottled water has been increasing by at least 10% every year since 2008, with the fastest growth observed in Asia and South America (Gleick et al. 2012). In the United States, bottled water consumption has grown as much as 44% since 2010, with 9 out of 10 Americans wanting bottled water to be available whenever other drinks are sold, turning a $36.3 billion profit in 2020 (IBWA 2021). The use of different drinking water sources for human consumption instead of TW has been increasing (Girolamini et al. 2019).

Examples of two new sources of drinking water are self-standing microfiltered water vending machines (WVMs) and drinking water from soda fountains (SFs). These are commonly preferred alternatives to bottled water, and appear to be environmentally friendly, overcoming bottled water disposal and pollution drawbacks. These sources are typically equipped with reverse osmosis or activated carbon filters that can remove chlorine taste, odors, and organic and inorganic contaminants (Ramírez-Castillo et al. 2015).

SFs are commonly used to dispense beverages in most fast-food establishments where consumers either dispense their own beverages in a purchased cup, or employees use SFs to dispense purchased beverages for customers. SF machines dispense carbonated soft drinks and drinking water. The global soda water dispenser market was valued at $1.0 billion in 2018 and is expected to grow at a compound annual growth rate of 5.4% from 2019 to 2025 (GVR 2022). The majority of reports of water contamination from SFs come from mass media sources (Cox 2010; Park 2010). Water quality studies of drinking water from SFs in fast-food restaurants are scarce (Hertin 2011; Hu et al. 2011; Godard et al. 2013) despite the rapid growth and use of these devices.

Self-standing WVMs (or simply WVMs) are generally located inside or outside grocery stores, pharmacies, and convenience stores where consumers are able to purchase drinking water while shopping or eating. WVMs are connected to TW from the local water district and make use of various filtration systems. The use of water from WVMs has considerably increased due to its affordability compared to bottled water. WVMs can dispense 5-gallon, 3-gallon, and 1-gallon units of water, depending on the funds inserted into the machine. The largest WVM provider in California is the Primo Water Company, which owns the Glacier vending machine network. In 2001, the non-profit organization, Environmental Working Group, released a report in which it verified that the Glacier Water Company reported over 60% of its sales went to Latino or Asian customers (Bitton 2005; WHO 2022). It has been demonstrated that WVMs are generally located in low-income and immigrant communities (Cardaci et al. 2016). Although microbial contamination of drinking water from WVMs is understudied, Hile et al. (2020) reported the presence of genetic material from Salmonella spp, Listeria monocytogenes, and other pathogenic microorganisms from WVM in the Coachella Valley of Southern California. Of these samples, Hile et al. (2000) found that 32% had coliforms and 21% had heterotrophic plate counts (HPCs). Although outbreaks related to the consumption of bottled water are rarely reported, they nevertheless do occur (CDC 2020). In Italy, a study by Liguori et al. (2010) found that HPCs counted at 22 °C were 71 and 86% higher than the allowable values in non-carbonated water and carbonated water, respectively, and at 37 °C, HPCs counted were 81 and 88% for non-carbonated and carbonated water, respectively. The United States has several federal-, state-, and county-level drinking water regulations, although there is only limited regular monitoring and unenforced authority for drinking water from WVMs and SFs (White et al. 2010).

Waterborne pathogens and their related diseases are a major public health concern worldwide (Ramírez-Castillo et al. 2015). The presence of pathogenic microorganisms in drinking water is a serious public health concern and cannot be overemphasized. Although waterborne outbreaks have considerably declined over the past 20 years (Jacobsen & Koopman 2004; Levy et al. 2018; Barrett 2019; Gharpure et al. 2019), waterborne microbial agents, such as Salmonella typhimurium, Vibrio cholerae, Legionella, E. coli O157:H7, and Pseudomonas have been implicated in acute gastrointestinal illnesses, acute respiratory illnesses, hepatitis, and several deaths (Ramírez-Castillo et al. 2015). In the United Kingdom, and many other developed countries, Campylobacter jejuni is the cause of most rapid onset of gastrointestinal infections resulting in acute morbidity and mortality, with an estimated 2 million cases per year, and mortalities estimated to be greater than 2,000 people annually. In these cases, the majority of infections are sporadic and the sources of infection are rarely determined (Cowden 1992).

It has been demonstrated that water quality deterioration may often be related to biofilm formation (Farhadkhani et al. 2014). In devices such as WVMs and SFs, high surface-to-volume ratios, the absence or low concentrations of residual chlorine, and stagnation periods are all factors that influence bacterial growth and proliferation (Farhadkhani et al. 2014). Biofilms are organized communities of organisms widely present in nature that represent serious problems in environmental, industrial, and medical settings (Szymanska 2003). They also play an important role in bacterial persistence in water lines and water systems, shielding them from disinfectants and adverse environmental conditions (Farhadkhani et al. 2014). Additionally, these films can also harbor pathogenic microorganisms (Flemming 2002), causing serious public health concerns.

There is a well-known disparity (Madison 2019) in drinking water monitoring where urban high-income areas have better monitoring and water quality than rural areas. This disparity exists in the rural and unincorporated communities known as Thermal, Oasis, Mecca, and North Shore located in the Eastern Coachella Valley (ECV) of Riverside County, Southern California, USA. In these communities, the water contamination issue is well known among community members and stigmatized due to previous reports of arsenic contamination in groundwater. This contamination is present for many of the rural residents who live in mobile homes that are supplied with untreated well water (Pierce & Jimenez 2015).

Given the importance of drinking water safety, this study was conducted to assess the quality of drinking water from WVMs and SFs in the ECV and compare them to TW collected in the community. We hypothesized that drinking water from WVMs and restaurants in the ECV is contaminated with pathogenic bacteria and that our swab samples from the machine spigots contain more bacteria than samples from the corresponding bulk water samples. We also postulated that drinking water from SFs is contaminated with elevated bacterial colony-forming units (CFUs) and pathogenic microorganisms. We hypothesized that TW samples from the ECV have fewer bacteria than water samples from WVMs and SFs.

Because our overall aim is to improve the quality of drinking water in this community, we adopted a problem-solving method that characterized the physico-chemical parameters that influence the microbial contamination. We focused on identifying the presence of DNA of select microbes with parallel assessments of pH, electrical conductivity (EC), free chlorine, and total dissolved solids (TDS). This problem-solving focus recognizes that microbial contamination could be exacerbated by other water quality issues. We used quantitative polymerase chain reaction (qPCR) for the identification of the six selected microorganisms.

Study site

The present study was carried out in the ECV, a desert area situated within the Imperial Valley in Southern California (33°36′46.9″N, 116°08′47.2″W) characterized by an arid climate. It extends southeast into Riverside County for approximately 72.4 km, from the San Bernardino Mountains to the northern shore of the Salton Sea. It is limited on the West by the San Jacinto Mountains and the Santa Rosa Mountains, and on the North and East by the Little San Bernardino Mountains (Figure 1). The ECV includes the city of Coachella and the unincorporated communities of Thermal, Oasis, Mecca, and North Shore. These communities are largely Latino, made up of approximately 14% of undocumented immigrants and agricultural-worker families that contribute approximately $430 million per annum to the gross domestic product of the USA (PUCDC 2020).
Figure 1

Map featuring California State, San Bernardino County, and the Eastern Coachella Valley.

Figure 1

Map featuring California State, San Bernardino County, and the Eastern Coachella Valley.

Close modal

Sample collection

Prior to sampling, we sterilized sampling bottles (1-L glass bottles) for WVMs, and metal water bottles (0.5 L) for SFs, by washing with soap and bleach, then rinsing with deionized water before autoclaving at 121 °C for 15 min. Bottle tops and SF sampling bottle covers (made of plastic) were immersed in a water bath before autoclaving to prevent melting. We aseptically added 1 mg of sodium thiosulfate to each 1 L bottle used for WVMs, and 0.5 mg of sodium thiosulfate to each 0.5 L bottle used to sample water from SFs, to neutralize the chlorine (Cl2) in sampled water.

In the field, we collected a total of 2 L of water samples from each WVM, and swabbed the interior surface of spigots which were uniformly 5 cm deep and 2 cm wide in diameter. We additionally collected 50 mL of water sample for physico-chemical parameters that were measured on site. We also collected a matched tap water (TW) sample from the same building that provided water to the WVM. We used the HM digital TDS-4 meter (HM digital®, Redondo Beach, California, USA) to measure total dissolved solids (TDS) in mg·L−1, and EC in μS·cm−1. We measured temperature (°C) and pH using a portable Omega meter (Connecticut, USA), and free Cl2 (mg·L−1 Cl2) using the HACH DR 300 DPD colorimetric method 8021 (Hach, Loveland, Colorado, USA). Instruments used for physico-chemical parameters were all calibrated in the laboratory prior to sampling according to manufacturer instructions. Each sampling bottle was labeled with the WVM code, sampling date, time, and site. Collected water samples were immediately placed on ice in a cooler and transported to the laboratory, where samples were immediately processed within 6 h. Unless otherwise indicated, all samples were processed at room temperature in duplicates.

We collected 0.5 L of drinking water from SFs by either directly placing a sterile sampling bottled under the water spigot of a soda dispenser in a fast-food restaurant, or by requesting a water sample from a restaurant staff member. The fast-food restaurants were not aware of the study. We purchased a meal or a small drink before collecting water from their dispensers. For water sampled directly from the SFs, care was taken not to contaminate the lid during the opening and closing of the sample bottles. For water samples handed out by waiters in a cup, we carefully transferred SF water samples into sterile water bottles. All samples were labeled and within 1 h transported on ice to our laboratory for analysis.

Heterotrophic plate counts

We prepared 100 mm plates for heterotrophic bacteria plate counts using BD™ Difco™ R2A Agar (Fisher Scientific, Ontario, California, USA) according to the manufacturer's recommendations, a day before sample collection.

To test for heterotrophic bacteria in our samples, we streaked 100 μL of water sample directly onto prelabeled R2A agar plates in duplicates without dilution (100) and 1 mL of water sample was diluted 1:10 with sterile phosphate buffer saline (PBS) in three microcentrifuge tubes. All streaked R2A plates were incubated at 35 °C for 48 h. Colonies were counted afterward, and results expressed as colony-forming units per milliliter (CFU·mL−1) for WVMs and tap water samples. For swab samples, the inner surface area for the spigot was swabbed (approximately 1 cm radius × 5 cm height = 34.5 cm2) and was used to calculate HPCs from swabs in CFU•cm−2. We also set the detection limit for HPC to be below 10 CFU·mL−1.

Coliforms/E. coli

We used the Colilert reagent test (IDEXX, Maine, USA) to detect and count total coliform and E. coli cells in water samples. We mixed 100 mL of water samples with Colilert reagent in a sterile 100-mL bottle that was later sealed and shaken thoroughly to mix. This solution was poured into a Quanti-Tray labeled with the sample identification number and sealed with the IDEXX Quanti-Tray Sealer. Quanti-Trays were incubated at 35 °C for 24 h, and the presence of total coliform was confirmed by a yellow color in Quanti-Tray wells. We determined the presence of E. coli by fluorescence emitted when Quanti-Trays were exposed to long-wave (365 nm) UV light.

Filtration

After physico-chemical and Quanti-Trays measurements, we assembled a Whatman vacuum filtration system (Cleves, Ohio, USA) to filter approximately 1,800 mL of water sample from each WVM visited, and 0.5 L from each fast-food restaurant the same day through a 0.45 μm MF Millipore™ membrane (Millipore Sigma, USA). All glass funnels and filter frit were sterilized by bleaching, then rinsing with deionized water, then autoclaving. We further sterilized the glassware using a benchtop U.V. sterilizer (Millipore, Sigma, USA) for approximately 5 min. After the vacuum and filter were assembled, each water sample was poured in and filtered. Each filter was aseptically removed after filtration and placed in a labeled sterile 50-mL microcentrifuge tube, containing 10 μL of sterile PBS. A water bath sonicator was used for 5 min at 37 °C to remove bacteria from the filters. Samples were further centrifuged at 12,000 rpm for 5 min for DNA extraction.

In-house standard curve

The quantitative analyses from qPCR were completed by creating standard curves with the reference microbes. Ten-fold serial dilutions of genomic DNA extracted from stock solutions were prepared. In this study, we used stock solutions of Salmonella typhimurium (ENVH Carolina 155351A), L. monocytogenes (ATCC® 7644), Pseudomonas aeruginosa (ATCC® 27853), Enterococcus faecalis (ATCC® 29212), C. jejuni (ATCC® 33291 and Escherichia coli (ATCC® 25922). The stock microorganisms were enriched overnight in liquid BD™ trypticase soy broth (Fisher Scientific, USA) to an approximate concentration of 1E8·mL−1 for P. aeruginosa, S. typhimurum, and E. coli. We used an approximate concentration of 1E6·mL−1 for L. monocytogenes and C. jejuni. To further prepare the stock for the standard curve calculation, we used selective media to validate the concentration in each stock solution. From there we used a DNA extraction kit on the stock solution in parallel with our plate count methods so that we could have a CFU·mL−1 estimates and a DNA extraction for the same stock. To estimate CFU·mL−1, plate colonies were counted the next day and averaged to determine the original suspension. The suspensions were serially diluted 1:10 in PBS, and 100 μL of the last three dilutions were plated in duplicate on selective media, then incubated overnight at 35 °C. In addition, 1.5 mL of the suspension was used for immediate DNA extraction. A 10-fold dilution series was then created from each template and assayed in duplicate using a SYBR Green I assay (Sigma–Aldrich, St. Louis, Missouri, USA). Regression lines from the dilution curve with R2 > 0.95 were used to determine the concentration of unknown samples.

DNA extraction

To extract DNA from environmental microorganisms, we used GenEluteTM Bacterial Genomic DNA KIT (Sigma–Aldrich, Missouri, USA). For field samples, we used the modified gram-positive extraction procedure described by the manufacture. After filtration and sonication, we centrifuged samples for 2 min at 12,000 rpm without the overnight enrichment step recommended by the manufacturer, to preserve original concentrations. Pelleted cells were resuspended in 200 mL of lysozyme solution and incubated for 30 min at 37 °C. We then added 20 μL of Proteinase K solution to the sample, followed by 200 μL of lysis solution, then incubated at 55 °C for 10 min after thorough vortexing. Columns were prepared by adding 500 μL of the column preparation solution to each pre-assembled GenElute Miniprep Binding Column and centrifuging for 1 min at 12,000 rpm. We then added 200 μL of 95% ethanol to the lysate and mixed thoroughly. The entire lysate was transferred into the binding column and centrifuged at 12,000 rpm for 1 min, after which the column was placed in a new collection tube and 500 μL of wash solution # 1 was added to the column and centrifuged for 1 min at 12,000 rpm. After discarding the eluate, we placed 500 μL of wash solution # 2 into the binding column and centrifuged for 3 min at 12,000 rpm. For DNA elution, we poured 200 μL of elution solution onto the column and allowed it to incubate for 5 min at room temperature, then centrifuged it for 1 min at 8,000× g. DNA concentration was estimated using a Nanodrop 1000 (Thermo-Scientific, Ramsey, Minnesota, USA).

Primer design

Primers used in this study were designed using the SILVA database (Quast et al. 2012). We also cross-checked all primers in the literature, and provided references as listed in Table 1. We selected primers based on annealing temperature, small amplicon size, and specificity to the selected microorganisms. Specificity of each primer was tested using Primer-Blast-NCBI (Boratyn et al. 2019).

Table 1

Primer sets of selected microorganisms with their various amplicon sizes and justification references used in qPCR

Target microorganismsPrimer sets (5′–3′)SizeJustificationReferences
Salmonella spp. FGGAAACGGTGGCTAATACC 103 Local Liu et al. (2018)  
 CCTCACCAACAAGCTAATCC  contaminant  
Listeria monocytogenes GATGATCAGGTAGATAGGTTTGG 119 Local Gião & Keevil (2014)  
Campylobacter jejuni CCTAACTGAGCCCTTTCTTC  contaminant  
 CCCTATCAAACTCCGAATACC 93 Local Whiley et al. (2013)  
Pseudomonas aeruginosa GGTAGTCTGGGTTGTTTCC  contaminant  
 GAGCAGGTTGAAGGTTAGG 111 Similar Liguori et al. (2010)  
Enterococcus faecalis GCTAATCAAGCTCGGAGATAG  study  
 TTGTGTTATGAACCCTCTAACC 124 Indicator Girolamini et al. (2019)  
E. coli GGTTCCCTCAGAATGGTTG  bacteria  
 CTATGTGTTGTTGGGTAGGG 423 Indicator Luby et al. (2015)  
 GATGTTACCTGATGCTTAGAGG  bacteria  
Target microorganismsPrimer sets (5′–3′)SizeJustificationReferences
Salmonella spp. FGGAAACGGTGGCTAATACC 103 Local Liu et al. (2018)  
 CCTCACCAACAAGCTAATCC  contaminant  
Listeria monocytogenes GATGATCAGGTAGATAGGTTTGG 119 Local Gião & Keevil (2014)  
Campylobacter jejuni CCTAACTGAGCCCTTTCTTC  contaminant  
 CCCTATCAAACTCCGAATACC 93 Local Whiley et al. (2013)  
Pseudomonas aeruginosa GGTAGTCTGGGTTGTTTCC  contaminant  
 GAGCAGGTTGAAGGTTAGG 111 Similar Liguori et al. (2010)  
Enterococcus faecalis GCTAATCAAGCTCGGAGATAG  study  
 TTGTGTTATGAACCCTCTAACC 124 Indicator Girolamini et al. (2019)  
E. coli GGTTCCCTCAGAATGGTTG  bacteria  
 CTATGTGTTGTTGGGTAGGG 423 Indicator Luby et al. (2015)  
 GATGTTACCTGATGCTTAGAGG  bacteria  

Real-time PCR (qPCR)

Real-time PCR was performed using a C1000 Touch Thermal Cycle CFX 96 (Bio-Rad, Hercules, USA). Each 96-well plate reaction mixture (20 μL) contained 10 μL of iTaq Universal SYBR Green Supermix (Bio-Rad, California, USA), 7 μL of nanopure distilled water, 1 μL of forward primers, 1 μL of reverse primers, and 1 μL of the extracted sample's genomic deoxyribonucleic acid (gDNA). In the 96-well plate set-up, we had positive control wells with gDNA from target microorganisms, negative controls with only deionized water, and a common mix without the sample gDNA as our no-template control (NTC). This NTC allowed quality control for contamination, and any plates with compromised NTCs were not used. The thermocycling program was 40 cycles at 95 °C for 3 min for the initial cycle, 95 °C for 10 s, and 55 °C for 30 s. All amplifications and standards were run on the same CFX 96 Real-Time instrument.

Physico-chemical parameters

A total of 72 samples were collected in this study. The physico-chemical parameters considered were limited to temperature, EC, pH, free chlorine, and TDS. Table 2 presents physico-chemical parameters for WVMs. Water temperature from WVMs ranged from 18.2 °C for WVM11 to 32.8 °C for WVM13.

Table 2

Physico-chemical parameters including temperature, electrical conductivity (EC), total dissolved solids (TDS), pH, and free chlorine, measured from water vending machines (WVMs) of the Eastern Coachella Valley

SampleTemp (°C)EC (μS·cm1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
WVM1 19.45 2.5 1.81 6.99 0.2 
WVM2 30.55 0.8 0.51 6.91 0.1 
WVM3 30.5 1.2 0.80 6.67 0.26 
WVM4 28.4 2.1 1.49 7.41 0.1 
WVM5 28.05 1.2 0.80 7.31 0.1 
WVM6 32.15 7.4 6.06 7.36 0.02 
WVM7 26.8 0.8 0.51 7.58 0.1 
WVM8 30.9 1.42 7.05 0.1 
WVM9 25 1.2 0.80 6.96 0.05 
WVM10 22.5 0.1 0.05 7.41 0.1 
WVM11 18.2 0.1 0.05 6.65 0.1 
WVM12 19.4 2.7 1.98 7.38 0.05 
WVM13 32.8 2.1 1.49 7.14 0.12 
WVM14 32.1 0.1 0.05 7.31 0.08 
WVM15 8.1 0.3 0.17 7.77 0.07 
WVM16 28.5 0.1 0.05 7.92 0.2 
WVM17 29.5 0.3 0.17 7.59 0.1 
WVM18 20.1 5.4 4.27 7.49 0.08 
WVM19 26 0.2 0.11 7.22 0.03 
WVM20 29 32 30.89 6.12 0.1 
WVM21 22 <1 0.05 5.9 0.01 
WVM22 29 7.54 5.57 0.1 
WVM23 27 0.3 0.17 6.4 0.1 
WVM24 31 41 40.70 5.9 0.03 
WVM25 32 28 26.63 6.2 0.01 
WHO 400–600 50–250 6–8.5 <0.2 
SampleTemp (°C)EC (μS·cm1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
WVM1 19.45 2.5 1.81 6.99 0.2 
WVM2 30.55 0.8 0.51 6.91 0.1 
WVM3 30.5 1.2 0.80 6.67 0.26 
WVM4 28.4 2.1 1.49 7.41 0.1 
WVM5 28.05 1.2 0.80 7.31 0.1 
WVM6 32.15 7.4 6.06 7.36 0.02 
WVM7 26.8 0.8 0.51 7.58 0.1 
WVM8 30.9 1.42 7.05 0.1 
WVM9 25 1.2 0.80 6.96 0.05 
WVM10 22.5 0.1 0.05 7.41 0.1 
WVM11 18.2 0.1 0.05 6.65 0.1 
WVM12 19.4 2.7 1.98 7.38 0.05 
WVM13 32.8 2.1 1.49 7.14 0.12 
WVM14 32.1 0.1 0.05 7.31 0.08 
WVM15 8.1 0.3 0.17 7.77 0.07 
WVM16 28.5 0.1 0.05 7.92 0.2 
WVM17 29.5 0.3 0.17 7.59 0.1 
WVM18 20.1 5.4 4.27 7.49 0.08 
WVM19 26 0.2 0.11 7.22 0.03 
WVM20 29 32 30.89 6.12 0.1 
WVM21 22 <1 0.05 5.9 0.01 
WVM22 29 7.54 5.57 0.1 
WVM23 27 0.3 0.17 6.4 0.1 
WVM24 31 41 40.70 5.9 0.03 
WVM25 32 28 26.63 6.2 0.01 
WHO 400–600 50–250 6–8.5 <0.2 

The physicho-chemical results for SFs are presented in Table 3. Except for SF11 that presented a water temperature of 32 °C, all SF water temperatures ranged from 14.3 to 28 °C. We also recorded pH ranging from 4.9 to 8.1 for SF7 and SF3, respectively.

Table 3

Physico-chemical parameters including temperature, electrical conductivity (EC), total dissolved solids (TDS), pH, and free chlorine, measured from fast-food soda fountains (SFs) of the Eastern Coachella Valley

Fast-food IDTemp (°C)EC (μS·cm–1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
SF1 19.3 0.1 0.05 6.5 
SF2 22.5 0.2 0.11 6.12 0.16 
SF3 18.2 0.1 0.05 8.1 
SF4 24 0.1 0.05 6.45 0.02 
SF5 16.3 0.27 0.15 5.43 0.17 
SF6 15 0.3 0.17 7.39 0.12 
SF7 18 0.37 0.22 4.95 0.14 
SF8 18.2 0.21 0.12 6.19 
SF9 14.3 0.29 0.17 6.16 0.06 
SF10 25 0.1 0.05 6.82 
SF1 32 0.1 0.05 7.05 
SF12 28 0.2 0.11 7.9 0.02 
WHO 400–600 50–250 6–8.5 <0.2 
Fast-food IDTemp (°C)EC (μS·cm–1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
SF1 19.3 0.1 0.05 6.5 
SF2 22.5 0.2 0.11 6.12 0.16 
SF3 18.2 0.1 0.05 8.1 
SF4 24 0.1 0.05 6.45 0.02 
SF5 16.3 0.27 0.15 5.43 0.17 
SF6 15 0.3 0.17 7.39 0.12 
SF7 18 0.37 0.22 4.95 0.14 
SF8 18.2 0.21 0.12 6.19 
SF9 14.3 0.29 0.17 6.16 0.06 
SF10 25 0.1 0.05 6.82 
SF1 32 0.1 0.05 7.05 
SF12 28 0.2 0.11 7.9 0.02 
WHO 400–600 50–250 6–8.5 <0.2 

The physico-chemical parameters of TW samples are presented in Table 4. We found the average Cl2 was 0.12·mg L−1 with a maximum of 0.5 mg·L−1. When comparing WVMs, TW and SF, TW samples had the highest average pH at 5.12. Our results also indicated that TDS ranged from 16 mg·L−1 for TW16 to 3,720 mg·L−1 for TW10. The EC recorded ranged from 0.3 μS·cm−1 for TW14 to 34 μS·cm−1 for TW10. When comparing physico-chemical parameters of WVMs, SFs, and TW, we observed that WVMs had the highest water temperature followed by TW. However, for EC, pH, and Cl2, TW ranged higher compared to WVM and SF samples (Figure 2).
Table 4

Physico-chemical parameters including temperature, electrical conductivity (EC), total dissolved solids (TDS), pH, and free chlorine, measured from tap water (TW) of the Eastern Coachella Valley

CodesTemp (°C)EC (μS·cm–1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
TW1 24 20.3 18.63 
TW2 22 20.3 18.63 
TW3 21 17 15.29 
TW7 21 17 15.29 
TW9 21 17 15.29 
TW10 22 34 33.05 
TW13 29.8 1.2 0.80 8.28 0.5 
TW14 27.4 0.3 0.17 8.75 0.01 
TW15 27.2 0.5 0.30 7.54 0.16 
TW16 28 0.6 0.37 9.12 0.02 
TW17 29.5 0.6 0.37 8.78 0.02 
TW18 21.9 0.4 0.24 7.77 0.02 
WHO 400–600 50–250 6–8.5 <0.2 
CodesTemp (°C)EC (μS·cm–1)TDS (mg·L−1)pHFree chlorine (mg·L−1)
TW1 24 20.3 18.63 
TW2 22 20.3 18.63 
TW3 21 17 15.29 
TW7 21 17 15.29 
TW9 21 17 15.29 
TW10 22 34 33.05 
TW13 29.8 1.2 0.80 8.28 0.5 
TW14 27.4 0.3 0.17 8.75 0.01 
TW15 27.2 0.5 0.30 7.54 0.16 
TW16 28 0.6 0.37 9.12 0.02 
TW17 29.5 0.6 0.37 8.78 0.02 
TW18 21.9 0.4 0.24 7.77 0.02 
WHO 400–600 50–250 6–8.5 <0.2 

/ indicates missing data.

Figure 2

Averages of physico-chemical parameters for water vending machines (WVMs), soda fountains (SFs), and tap water (TW) of the Eastern Coachella Valley.

Figure 2

Averages of physico-chemical parameters for water vending machines (WVMs), soda fountains (SFs), and tap water (TW) of the Eastern Coachella Valley.

Close modal

Microbiological analysis

Results of bacteriological analysis of WVMs (n = 24), swabs from WVMs (n = 24), SFs (n = 12), and TW (n = 12) are presented in Tables 58, respectively. Results for HPC in Table 5 demonstrated that 20% of WVMs had HPC above 500 CFU·mL−1. Table 5 also indicated that WVM10, WVM12, WVM13, and WVM16 had total coliforms. No microbial growth was observed in the negative control blanks for HPCs or IDEXX methods.

Table 5

Biological characteristics of water vending machines (WVMs) in the ECV including HPCs

SamplesHPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
WVM1 6.2 × 103 <1 
WVM2 <10 <1 
WVM3 <10 <1 
WVM4 3.2 × 102 <1 
WVM5 <10 <1 
WVM6 <10 <1 
WVM7 <10 <1 
WVM8 9.1 × 103 <1 
WVM9 <10 <1 
WVM10 <10 8.5 
WVM11 <10 <1 
WVM12 <10 13.2 
WVM13 3.6 × 104 3.1 
WVM14 3.0 × 102 <1 
WVM15 <10 
WVM16 <10 435.2 
WVM17 <10 <1 
WVM18 <10 <1 
WVM19 <10 <1 
WVM20 <10 <1 
WVM21 <10 <1 
WVM22 <10 <1 
WVM23 <10 <1 
WVM24 <10 <1 
WVM25 <10 <1 
EPA <500  0 
SamplesHPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
WVM1 6.2 × 103 <1 
WVM2 <10 <1 
WVM3 <10 <1 
WVM4 3.2 × 102 <1 
WVM5 <10 <1 
WVM6 <10 <1 
WVM7 <10 <1 
WVM8 9.1 × 103 <1 
WVM9 <10 <1 
WVM10 <10 8.5 
WVM11 <10 <1 
WVM12 <10 13.2 
WVM13 3.6 × 104 3.1 
WVM14 3.0 × 102 <1 
WVM15 <10 
WVM16 <10 435.2 
WVM17 <10 <1 
WVM18 <10 <1 
WVM19 <10 <1 
WVM20 <10 <1 
WVM21 <10 <1 
WVM22 <10 <1 
WVM23 <10 <1 
WVM24 <10 <1 
WVM25 <10 <1 
EPA <500  0 
Table 6

Biological characteristics of water vending machines (WVMs) swabs in the ECV including heterotrophic plate counts (HPCs)

SamplesHPCs (CFU·cm−2)Total coliforms (MPN·1 cm−2)
Swab1 29 7.4 
Swab2 3.3 × 103 172.3 
Swab3 20 435.2 
Swab4 1.1 × 103 28.2 
Swab5 2.0 × 103 111.9 
Swab6 1.1 × 104 4.1 
Swab7 1.9 × 103 7.5 
Swab8 9.5 × 102 13.4 
Swab9 1.2 × 103 435.2 
Swab10 2.9 × 103 410.6 
Swab11 46 435.2 
Swab12 2.4 × 103 7.4 
Swab13 31 10.7 
Swab14 1.2 × 102 435.2 
Swab15 3.5 × 103 54.4 
Swab16 22 23.2 
Swab17 1.6 × 103 3.1 
Swab18 29 <1 
Swab19 7.2 × 104 435.2 
Swab20 <10 435.2 
Swab21 <10 <1 
Swab22 <10 435.2 
Swab23 <10 <1 
Swab24 <10 10.7 
Swab25 <10 435.2 
EPA <500 
SamplesHPCs (CFU·cm−2)Total coliforms (MPN·1 cm−2)
Swab1 29 7.4 
Swab2 3.3 × 103 172.3 
Swab3 20 435.2 
Swab4 1.1 × 103 28.2 
Swab5 2.0 × 103 111.9 
Swab6 1.1 × 104 4.1 
Swab7 1.9 × 103 7.5 
Swab8 9.5 × 102 13.4 
Swab9 1.2 × 103 435.2 
Swab10 2.9 × 103 410.6 
Swab11 46 435.2 
Swab12 2.4 × 103 7.4 
Swab13 31 10.7 
Swab14 1.2 × 102 435.2 
Swab15 3.5 × 103 54.4 
Swab16 22 23.2 
Swab17 1.6 × 103 3.1 
Swab18 29 <1 
Swab19 7.2 × 104 435.2 
Swab20 <10 435.2 
Swab21 <10 <1 
Swab22 <10 435.2 
Swab23 <10 <1 
Swab24 <10 10.7 
Swab25 <10 435.2 
EPA <500 
Table 7

Biological characteristics of drinking soda fountains (SFs) water in the ECV including heterotrophic plate counts (HPCs)

SamplesHPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
SF1 <10 <1 
SF2 <10 2,419.6 
SF3 2.03 × 103 2,419.6 
SF4 <10 22.6 
SF5 <10 5.3 
SF6 5.40 × 104 2,419.6 
SF7 <10 <1 
SF8 <10 <1 
SF9 <10 <1 
SF10 4.30 × 104 3.1 
SF11 <10 <1 
SF12 <10 <1 
EPA <500 
SamplesHPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
SF1 <10 <1 
SF2 <10 2,419.6 
SF3 2.03 × 103 2,419.6 
SF4 <10 22.6 
SF5 <10 5.3 
SF6 5.40 × 104 2,419.6 
SF7 <10 <1 
SF8 <10 <1 
SF9 <10 <1 
SF10 4.30 × 104 3.1 
SF11 <10 <1 
SF12 <10 <1 
EPA <500 
Table 8

Biological characteristics of tap water (TW) in the ECV including heterotrophic plate counts (HPCs)

Samples
HPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
Tap 1 <10 <1 
Tap 2 <10 11.15 
Tap 3 <10 <1 
Tap 7 <10 45.65 
Tap 9 <10 <1 
Tap10 <10 <1 
Tap 13 1.1 × 106 <1 
Tap 14 8.3 × 104 3.6 
Tap15 <10 138.5 
Tap16 9.2 × 104 6.55 
Tap17 3.0 × 104 <1 
Tap 18 <10 9.95 
EPA <500 
Samples
HPCs (CFU·mL−1)Total coliforms (MPN·100 mL−1)
Tap 1 <10 <1 
Tap 2 <10 11.15 
Tap 3 <10 <1 
Tap 7 <10 45.65 
Tap 9 <10 <1 
Tap10 <10 <1 
Tap 13 1.1 × 106 <1 
Tap 14 8.3 × 104 3.6 
Tap15 <10 138.5 
Tap16 9.2 × 104 6.55 
Tap17 3.0 × 104 <1 
Tap 18 <10 9.95 
EPA <500 

We present results from microbial analysis of swabs in Table 6, that demonstrate that 76% of swabs had HPC above 500 CFU.mL−1. Results for the presence of total coliforms for swab samples are also presented in Table 6 and ranged from 3.1 to 435.2 MPN·100 mL−1. We found that 60% of swabs had total coliforms. In Table 7, we show 25% of SF samples had HPC values above 500 CFU·mL−1. We also show in Table 7 that 42% of SFs had total coliforms. For TW, we demonstrate in Table 8 that 33% of samples collected had HPC values above 500 CFU mL−1, and 50% of collected samples had total coliforms. We compare the concentration of HPCs from WVMs, swabs, SFs, and TW in Figure 3 and found that TW samples had the highest concentrations of HPCs, followed by swab samples. We also compared the concentration of total coliforms between WVMs, swabs, SFs, and TW samples, shown in Figure 4 and found that SFs had the highest concentrations of total coliforms, followed by swabs. We also observed that water in SF water bottles handled by employees were all positive for coliforms. In Figure 5(a), we demonstrated that E. faecalis was the predominant gene targets identified in WVMs when using the qPCR quantification method described in the current study. We also show in Figure 5(b) that Salmonella spp was the most identified gene target in TW samples, followed by P. aeruginosa, when using qPCR. In swab samples, P. aeruginosa was the most predominant gene target identified, followed by L. monocytogenes, as shown in Figure 5(c),. When comparing swabs and WVMs for microbial gene target concentration using our qPCR method, we found that except for E. faecalis dominance in WVMs, all identified selected microorganism gene targets predominated in swab samples (Figure 6).
Figure 3

Comparison of heterotrophic plate count (HPC) most probable numbers between water vending machines (WVMs) swabs, fast-food soda fountains (SFs), and tap water (TW).

Figure 3

Comparison of heterotrophic plate count (HPC) most probable numbers between water vending machines (WVMs) swabs, fast-food soda fountains (SFs), and tap water (TW).

Close modal
Figure 4

Comparisons of total coliform concentrations from water vending machines (WVMs), swabs from water vending machines, soda fountains (SFs), and tap water (TW) of the Eastern Coachella Valley.

Figure 4

Comparisons of total coliform concentrations from water vending machines (WVMs), swabs from water vending machines, soda fountains (SFs), and tap water (TW) of the Eastern Coachella Valley.

Close modal
Figure 5

Microbial concentration of selected microorganisms based on qPCR quantification in water vending machines (a), in tap water (b) and in swabs (c) of the Eastern Coachella Valley.

Figure 5

Microbial concentration of selected microorganisms based on qPCR quantification in water vending machines (a), in tap water (b) and in swabs (c) of the Eastern Coachella Valley.

Close modal
Figure 6

Comparison of microbial quantification of selected microorganisms from water vending machines (WVMs) and swabs from water vending machines of the Eastern Coachella Valley, using the qPCR method.

Figure 6

Comparison of microbial quantification of selected microorganisms from water vending machines (WVMs) and swabs from water vending machines of the Eastern Coachella Valley, using the qPCR method.

Close modal

Although illness outbreaks related to the consumption of bottled or dispensed water are rarely reported, they do occur (Cardaci et al. 2016). Waterborne pathogens and related diseases are major public health concerns worldwide. However, it has been demonstrated that risk of contamination in drinking water is higher in rural areas than urban areas (Madison 2019). Moreover, drinking water quality analyses from WVMs and SFs are scarce. To the best of our knowledge, microbial contamination of drinking water from SFs, TW, WVMs and nozzle swabs of WVMs have not been previously evaluated, quantified, or analyzed, especially in the ECV. The goal of this study was to evaluate the quality of drinking water from WVMs, using 5-gallon jugs, nozzle swabs of WVMs, SFs, and TW in the ECV, using cultivable and molecular methods for estimates of contamination.

Results for physico-chemical parameters indicated that the mean temperature of WVMs varied. These differences in mean temperature may be explained by their individual locations, and their relative exposure to ambient heat or direct sunlight. SFs are generally located indoors (in fast-food restaurants) and connected to cooling systems for customer convenience, and consequently are much cooler than other sources, such as WVMs and TW. Tap water samples were generally collected from outdoor TW spigots, where garden hoses were connected, or indoors, from sinks that are connected through ground pipes to the local water district. The majority of WVMs however, were at times exposed to ambient desert heat, resulting in elevated water temperatures. Nevertheless, drinking water temperature does not necessarily have a direct health impact, other than on aesthetic qualities. However, high temperatures between 25 and 42 °C have previously been implicated in robust biofilm formation, more so than for low temperatures (4–10 °C) (Roy et al. 2021). Our study showed that 72% of WVM, 25% of SF, and 41% of TW samples had adequate water temperatures for the formation and growth of biofilms, which can harbor pathogenic microorganisms and therefore pose threats to human health and public safety. These findings are supported by a study by Farhadkanhi et al. (2014) in Iran which found that temperature had a significant effect on the HPC population in water coolers.

The pH measures the acid–base equilibrium achieved by compounds dissolved in water (Masood et al. 2015). Although drinking water pH does not necessarily impact human health directly, it has been demonstrated that high pH values (above 7.5) may cause pipes to be encrusted with deposits, while low-pH water may cause corrosion of pipe metals potentially impacting water quality (USGS 2019). However, in the current study, we found no health concerns related to water pH level.

Free Cl2 indicates the water source has been treated to kill disease-causing microorganisms. The Centers for Disease Control and Prevention (CDC) recommends a range of 0.2–2 mg·L−1 of Cl2 in TW (CDC 2014), while the World Health Organization (WHO) maximum allowable value for Cl2 concentrations in drinking water is 5 mg•L−1 (WHO 2017). Our results indicated that Cl2 measurements obtained from WVMs, and SFs fall within the recommended CDC and WHO requirements. For drinking water from WVMs and SFs, we found that Cl2 levels were mostly far below WHO recommendations, indicating filtration efficiency used by WVMs and SFs that effectively remove Cl2.

Although no guidelines have been established for drinking water TDS limits by the EPA, WHO recommends 600 mg•L−1 or less for aesthetic reasons (WHO 2017). We found that 83% of TW samples had TDS above the WHO recommended value. These results may be due to human activities or water sources, such as groundwater, which came from wells with high concentrations of soil. Similar results were found by both Wei et al. (2013) in China in his study of characterizing urban runoff pollution between dissolved and particulate phases, and Roșca et al. (2020) in Romania in their study on the impact of anthropogenic activities on water quality parameters of glacial lakes. The TDS concentrations above the WHO recommendation indicate a problem with either the filtration system or calcification of premises plumbing that accumulated over time leading to elevated TDS at the point of use. However, WVMs and SFs had TDS far below WHO recommended value. This indicated the potential effectiveness of filtration systems used in WVMs and SFs that can remove high concentrations of TDS from tap water to which they are connected.

Maintaining the microbiological quality of drinking water between the water treatment facility and the consumer's tap constitutes a serious challenge in drinking water safety (Fengyi et al. 2009; Sacchetti et al. 2014). Consequently, the evaluation of microbial quality of drinking water from WVMs, SFs and TW, is necessary to ensure compliance with quality standards. Heterotrophs are microorganisms that require organic carbon for growth. However, only a small proportion of microorganisms present in water are able to grow and become detectable in HPC test conditions (Bartram et al. 2003). The EPA sets the maximum permissible level of heterotrophic bacteria in drinking water at 500 CFU·mL–1 (EPA 2021). Our results indicated that HPC bacteria were present in 20% of samples from WVMs, 25% of samples from SFs, 33.3% of TW samples, and 76% of swab samples. Similar results were found by Boonhok et al. (2021) in Thailand, Phiri et al. (2021) in New Zealand and Ang & Tham (2020) in Malaysia who all reported bacterial counts above the stated drinking water limits for HPC (<500 CFU·mL–1) in raw water samples. The very high HPC concentrations from swab samples and low HPC concentrations in WVM bulk water samples may be explained by the presence of biofilms in spigots of WVMs, rather than the water samples themselves (Fengyi et al. 2009). This suggestion is supported by Cardaci et al. (2016) in their study in Italy about contamination in automatic vending-machines, where nozzles of WVMs were the most contaminated area. Additionally, Muhammad et al. (2020) in Malaysia in their study on microbiological analysis of drinking water from WVM found that all WVMs nozzles were contaminated with Stenotrophomonas, Pseudomonas, and Bacillus. In our study, we found 80% of WVMs had no HPC, yet 76% of swabs from the same WVMs had HPC above 500 CFU·mL–1, exceeding the acceptable level for drinking water set by the EPA. The formation of biofilms in WVMs is a serious problem that exposes purified and filtered water to potentially pathogenic microorganisms forming biofilms that can leach out into drinking water bought by consumers. In Iran, Farhadkhani et al. (2014) found that rubber-lined hoses had high levels of plastic, which encouraged bacterial growth. Thus, waterlines made of plastic material, and used for WVMs offer the ideal environment for biofilm formation (Zanetti et al. 2009). Moreover, narrow bore spigots made of plastic material constitutes a suitable surface for microorganism adhesion and biofilm formation (White et al. 2010; Sacchetti et al. 2014). Therefore, the high concentration of HPCs in swab samples, rather than in the WVMs themselves, is an indicator of likely biofilm formation in the spigots. Contamination of spigots may occur over time by the accumulation of microorganisms in WVM plastic water line systems. The present study supports previous findings by Farhadkhani et al. (2014) in Iran, Gião & Keevil (2014) in UK, and Wingender & Flemming (2011) in Germany in their studies assessing of drinking water quality from bottled water coolers. These authors all found biofilms in tap water that enter into the viable but non-cultivable state, and all concluded that the spigots of water dispensers are suitable surfaces to facilitate excessive growth of bacteria and biofilm formation. Additionally, Wingender & Flemming (2011) found Listeria monocytogens in biofilm from tap water. Results for total coliforms demonstrated 20% of WVM, 88% of swab, 41% of SF, and 50% of TW samples had total coliforms. Also, the mean values of total coliforms in WVMs, swabs, SFs, and TW, indicated that SFs had the highest mean concentration of total coliforms, followed by swabs. A previous study by White et al. (2010) in the US found that many of the SFs analyzed exceeded US drinking water standards including 20% of SFs sampled, with an HPC > 500 CFU·mL–1, 48% with coliform bacteria, and 6.7% with E. coli. TW and WVMs had the lowest mean concentration of total coliforms. Our findings regarding the presence of coliforms in the present study were in accordance with studies by Liguori et al. (2010) in Italy, Zanetti et al. (2009) in Italy, Baumgartner & Grand (2006) in Switzerland and Lévesque et al. (1994) in Canada that also found coliforms in WVM or coolers. The presence of total coliforms in drinking water indicates that environmental contamination with biological matter into drinking water systems may require investigation (WSDH 2016), and that there is a possible health risk to the population in relation to exposure to potential pathogenic microorganisms. Total coliforms are used as an indicator of other pathogens in drinking water, and as such, are used to determine the competence of water treatments (EPA 2021). The striking presence of coliforms in 88% of swabs, yet only 20% of WVMs is likely an indication of biofilm formation in spigots of WVMs that sporadically leach into water samples. The presence of HPCs exceeding the threshold set by the EPA for drinking water, and the presence of total coliforms in some WVMs and SFs is an indicator of microbial water quality deterioration, despite the effectiveness of the filtration system that was able to filter Cl2 from TW and result in parameters, such as pH, TDS, and EC, within required limits.

Municipal water systems in the US are monitored and required to comply with drinking water regulations. The present study sampled water from taps located in the ECV along with WVMs and SFs. The elevated concentrations of HPCs and the presence of total coliforms in our TW samples was unexpected and is in contrast to other studies that found higher concentrations of HPCs in water dispensers than the TW used to supply them (Liguori et al. 2010; Wingender & Flemming 2011; Farhadkhani et al. 2014; Sacchetti et al. 2014). Heterotrophic plate count results obtained in the current study from drinking water sampled from a water tank supplied by the Coachella Valley Water District to the ECV community were all below detection limit, with no coliform or E. coli (data not shown). However, TW collected during this study had elevated HPCs and coliforms. This may be explained by the fact that distribution systems and service lines influence the quality of water (Bitton 2005). Although the Coachella Water District provided clean water, according to results published on their website and the analysis of the water tank we analyzed, we can infer that the TW spigots, fixtures, or other premise plumbing are likely to be contaminated with biofilms. This is supported by studies that found drinking water quality was deteriorated by microbial contamination during transport before reaching the consumer (Bitton 2005; Arnal et al. 2010). We assume that since water quality from the tank was sufficient for drinking, and reports from the ECV water district confirm that quality, it is likely that tap water contamination was due to premise plumbing and biofilm formation overtime. For example, Huang et al. (2021) in their study characterizing microbiomes in both water and biofilms in Australia showed the formation of taxonomically diverse biofilms in premise plumbing. Similar results were found by Falkinham et al. (2015), and Huang et al. (2020), in the USA.

From our results for quantified selected microorganisms using qPCR, we found all selected microorganisms were represented in WVMs at different concentrations. However, the presence of selected microorganisms varied from one WVM to another. P. aeruginosa is an important opportunistic pathogen, is a serious threat to drinking water safety, and its predominance in drinking water is a serious public health concern. Pseudomonas aeruginosa is known for its resistance to disinfectants, such as chlorine, and for its ability to form biofilms. Although the detection of the presence of selected microorganisms in WVMs using qPCR does not indicate the presence of viable microorganisms in our samples (rather, the presence of genetic materials of target microorganisms), it does not eliminate the risk of exposure to pathogenic microorganisms. We found that P. aeruginosa mean concentration was elevated in TW and swabs. Also, the elevated mean concentration of P. aeruginosa in swabs almost equal to the concentration in TW in comparison to WVM (see Figure 5(b) supplemental), indicated that microorganisms piped in WVMs form biofilms in spigots and later leach into bottled water during the purchase of drinking water. In this study, E. faecalis was predominant among selected microorganisms in WVMs. E. faecalis is an opportunistic pathogen frequently found in mineral water and spring water used for human consumption, and may cause human urinary tract infections, endocarditis, and neonatal sepsis (Wei et al. 2017). Although qPCR is unable to distinguish between live versus dead microorganisms, it is able to identify genetic material of a microorganism alive or dead in a sample to a lower concentration, and greater sensitivity in comparison to traditional bacterial counting methods. Although we were unable to detect cultivatable E. coli, we were nevertheless able to determine the presence of E. coli genetic material in our samples. The presence of E. coli in drinking water is generally used as an indicator of drinking water quality and the risk of contamination with pathogenic microorganisms (Brown et al. 2008).

We found that TW samples had the highest mean concentration of Salmonella spp. We also found that WVM's, and swabs presented essentially the same mean concentration of Salmonella spp. However, the percent positive of Salmonella spp showed that swab samples were more contaminated with Salmonella spp than WVMs. Salmonella spp ranks high among microorganisms causing foodborne disease outbreaks, and approximately 32.7% of Salmonella spp outbreaks in the US have been associated with drinking water consumption (Liu et al. 2018). We can infer that Salmonella spp and L. monocytogenes contamination in WVMs comes from TW and biofilm formation in spigots that will then leach into drinking water purchased by consumers. Similar to the study in the US by White et al. (2010), we were not able to sample the TW supply directly before entering WVMs and consequently, we are unable to infer that the municipal tap water is the source for contamination of WVMs. Moreover, TW from the ECV complied to the EPA water quality standards. The dispensing nozzles, as well as the fittings that connect the WVM and SF machines to the municipal water distribution network may be the source of contamination (White et al. 2010). Moreover, previous studies have found that microbial populations were greater after passing through a dispenser than before, hence we suggest the contamination of the dispensed water likely happened in the machine itself. This suggestion is supported by Zanetti et al. (2009) who investigated water contamination in microfiltered water dispensers in Italy. Both Kohnen et al. (2005) in Germany and da Silva et al. (2008) in Brazil found similar results from their studies of microbiological quality of carbonated drinking water and the comparison of the bacteriological quality of tap water and bottled mineral water, respectively.

Microbial contamination of drinking water from SFs is understudied. We found that SFs in the ECV had the highest mean concentration of total coliforms in comparison to TW, swabs, and WVM samples. Although White et al. (2010) found no significant differences in the levels of microbial contamination between self-served and employee-served SFs, our data, although insufficient from which to draw conclusions, indicated all SFs served by employees were contaminated with coliforms. We suggest that further investigations should be carried out to compare the microbial contamination between self-served and employee-served SF water.

International drinking water quality monitoring programs have been established to prevent waterborne disease outbreaks through a requirement of drinking water infrastructure and maintenance. Failure to monitor water can lead to infrastructure failure and may expose people to pathogenic microorganisms. Concerns have been raised about the quality of alternative drinking water sources (WVMs and SFs) to TW from municipal water districts. To ensure safety of drinking water from WVMs and water from fast-food restaurants for communities living in the ECV, we designed this study to analyze drinking water samples from WVMs, SFs, and TW for physico-chemical parameters, as well as microbiological quality. We found that WVMs and SFs had microbial contamination above limits set by the EPA. Moreover, genetic material of selected pathogenic microorganisms was represented in both WVMs and SFs. Contrary to prior studies, we found that TW samples at point of use were greatly contaminated. We suggest biofilm formation in TW distribution systems is likely the main source of contamination. Since WVMs and SFs are connected to TW systems, biofilms likely form overtime in the water distribution systems, which are mainly made of plastic piping, and are ideal for biofilm growth. The quality of filtration systems used for WVMs and SFs appears to be insufficient to prevent consumers from drinking contaminated water. Dispensing nozzle structure and location are also suitable for biofilm formation, especially during the summer season. In this study, nozzle swabs demonstrated elevated bacterial contamination, supporting the idea that their location and structure are ideal for biofilm formation and summer drinking water contamination. To improve water quality from dispensed water, we recommend regular cleaning and flushing of dispensers by owners. We recommend regular flushing and cleaning of water dispensers and the use of nanoparticle coated tubes inside water dispensers to control the growth of biofilms in water dispensers.

We thank the Loma Linda University Department of Earth and Biological Sciences for funding this project. Our appreciation is extended to the Kerby Oberg laboratory for use of their instruments. We wish to thank Lance Pompe and Dustin Baumbach for their cartographic skills in producing the map. This research is part of the Loma Linda University Environmental Microbiology Research Laboratory and is Contribution No. 40 from the Marine Research Group (LLU).

All relevant data are included in the paper or its Supplementary Information.

The authors declare there is no conflict.

Ang
Y.-M.
&
Tham
H.-W.
2020
Coliform contamination on faucet surface of water vending machines in Klang Valley
.
Progress in Microbes & Molecular Biology
3
(
1
),
1
5
.
Arnal
J.
,
García-Fayos
B.
,
Sancho
M.
,
Verdú
G.
&
Lora
J.
2010
Design and installation of a decentralized drinking water system based on ultrafiltration in Mozambique
.
Desalination
250
(
2
),
613
617
.
Association IBW
2021
Bottled Water Consumption Shift – U.S. Consumption by Beverage Type 2010–2020 Virginia
.
IBWA
.
[updated 2021; cited 2022 1/31/22]. Available from: https://bottledwater.org/bottled-water-consumption-shift/.
Bartram
J.
,
Cotruvo
J.
,
Exner
M.
,
Fricker
C.
&
Glasmacher
A.
2003
Heterotrophic Plate Counts and Drinking-Water Safety: the Significance of HPCs for Water Quality and Human Health
.
IWA
,
London, UK
, p.
245
.
Bitton
G.
2005
Wastewater Microbiology
.
John Wiley & Sons
,
New York, NY, USA
.
Boonhok
R.
,
Borisut
S.
,
Chuklin
N.
,
Katzenmeier
G.
&
Srisuphanunt
M.
2021
Drinking water quality assessment from water dispensers in an educational institution
.
Water Supply
21
(
8
),
4457
4464
.
doi: 10.2166/ws.2021.189
.
Boratyn
M.
,
Thierry-Mieg
J.
,
Thierry-Mieg
D.
,
Busby
B.
&
Madden
L.
2019
Magic-BLAST, an accurate RNA-seq aligner for long and short reads
.
BMC Bioinformatics
20
(
1
),
405
.
Epub 2019 July 28. PubMed PMID: 31345161; PubMed Central PMCID: PMCPMC6659269. doi: 10.1186/s12859-019-2996-x
.
Brown
J. M.
,
Proum
S.
&
Sobsey
M. D.
2008
Escherichia coli in household drinking water and diarrheal disease risk: evidence from Cambodia
.
Water Science and Technology
58
(
4
),
757
763
.
Epub 2008/09/09. PubMed PMID: 18776609. doi: 10.2166/wst.2008.439
.
Cardaci
R.
,
Burgassi
S.
,
Golinelli
D.
,
Nante
N.
,
Battaglia
M.
,
Bezzini
D.
&
Messina
G.
2016
Automatic vending-machines contamination: a pilot study
.
Global Journal of Health Science
9
(
2
),
63
.
Centers for Disease Control and Prevention
.
2020
Commercially Bottled Water2020 Sept 08 2021 [cited 2021 sept 08 2021]. Available from: https://www.cdc.gov/healthywater/drinking/bottled/index.html
Centers for Disease Control and Prevention
.
2014
.
Cowden
J.
1992
Campylobacter: epidemiological paradoxes
.
BMJ: British Medical Journal
305
(
6846
),
132
.
Cox
L.
2010
Soda Fountains Squirt Fecal Bacteria, Study Finds
.
ABC
,
Los Angeles, CA, USA
.
da Silva
M. E. Z.
,
Santana
R. G.
,
Guilhermetti
M.
,
Camargo Filho
I.
,
Endo
E. H.
,
Ueda-Nakamura
T.
, Nakamura, C. V. & Filho, B. P. D.
2008
Comparison of the bacteriological quality of tap water and bottled mineral water
.
International Journal of Hygiene and Environmental Health
211
(
5–6
),
504
509
.
Falkinham
J. O.
,
Pruden
A.
&
Edwards
M.
2015
Opportunistic premise plumbing pathogens: increasingly important pathogens in drinking water
.
Pathogens
4
(
2
),
373
386
.
PubMed PMID. doi:10.3390/pathogens4020373
.
Farhadkhani
M.
,
Nikaeen
M.
,
Akbari Adergani
B.
,
Hatamzadeh
M.
,
Nabavi
B. F.
&
Hassanzadeh
A.
2014
Assessment of drinking water quality from bottled water coolers
.
Iran Journal of Public Health
43
(
5
),
674
681
.
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4449416/
.
Fengyi
S.
,
Mingfang
L.
,
Zhang
F.
,
Peng
L.
,
Kai
L.
&
Xinhui
X.
2009
Performance of microbiological control by a point-of-use filter system for drinking water purification
.
Journal of Environmental Sciences
21
(
9
),
1237
1246
.
Flemming
H.-C.
2002
Biofouling in water systems–cases, causes and countermeasures
.
Applied Microbiology and Biotechnology
59
(
6
),
629
640
.
Gharpure
R.
,
Perez
A.
,
Miller
A. D.
,
Wikswo
M. E.
,
Silver
R.
&
Hlavsa
M. C.
2019
Cryptosporidiosis outbreaks – United States, 2009–2017
.
Morbidity and Mortality Weekly Report
68
(
25
),
568
.
Gião
S.
&
Keevil
W.
2014
Listeria monocytogenes can form biofilms in tap water and enter into the viable but non-cultivable state
.
Microbial Ecology
67
(
3
),
603
611
.
Epub 2014/01/24. PubMed PMID: 24452996. doi: 10.1007/s00248-013-0364-3
.
Girolamini
L.
,
Lizzadro
J.
,
Mazzotta
M.
,
Iervolino
M.
,
Dormi
A.
&
Cristino
S.
2019
Different trends in microbial contamination between two types of microfiltered water dispensers: from risk analysis to consumer health preservation
.
International Journal of Environmental Research and Public Health
16
(
2
),
272
.
doi: 10.3390/ijerph16020272. PubMed PMID: 30669329
.
Gleick
P. H.
,
Allen
L.
,
Christian-Smith
J.
,
Cohen
M. J.
,
Cooley
H.
,
Heberger
M.
&
Schulte
P.
2012
The World's Water Volume 7: The Biennial Report on Freshwater Resources
.
Island Press
,
Washington, DC, USA
.
Godard
R. D.
,
Sharma
P.
,
Wagner
C. J.
,
Wilson
C. M.
,
Fleming-Haddock
A.
&
Beach
R. L.
2013
Repeated detection of microbes in beverages dispensed from soda fountain machines and the effect of flushing on microbial density
.
International Journal of Food Microbiology
163
(
2
),
218
222
.
https://doi.org/10.1016/j.ijfoodmicro.2013.03.007
.
Grand View Research G.
2022
Soda Water Dispenser Market Size, Share & Trends Analysis Report By Dispenser Style (Push Button, Lever), By Product (Countertop, Drop-in), By Region, And Segment Forecasts, 2019–2025. GVR-3-68038-266-2
.
Hertin
K. J.
2011
A comparative study of indicator bacteria present in ice and soda from Las Vegas food establishments. UNLV Theses, Dissertations, Professional Papers, and Capstones. 1282. http://dx.doi.org/10.34917/2825979
.
Hile
T. D.
,
Dunbar
S. G.
&
Sinclair
R. G.
2020
Microbial contamination of drinking water from vending machines of Eastern Coachella Valley
.
Water Supply
21
(
4
),
1618
1628
.
doi: 10.2166/ws.2020.372
.
Hu
Z.
,
Morton
L.
&
Mahler
R.
2011
Bottled water: United States consumers and their perceptions of water quality
.
International Journal of Environmental Research and Public Health
8
(
2
),
565
578
.
Epub 2011/02/21. PubMed PMID: 21556204. doi: 10.3390/ijerph8020565
.
Huang
C.
,
Shen
Y.
,
Smith
R. L.
,
Dong
S.
&
Nguyen
T. H.
2020
Effect of disinfectant residuals on infection risks from Legionella pneumophila released by biofilms grown under simulated premise plumbing conditions
.
Environment International
137
,
105561
.
https://doi.org/10.1016/j.envint.2020.105561
.
Huang
C. K.
,
Weerasekara
A.
,
Bond
P. L.
,
Weynberg
K. D.
&
Guo
J.
2021
Characterizing the premise plumbing microbiome in both water and biofilms of a 50-year-old building
.
Science of The Total Environment
798
,
149225
.
https://doi.org/10.1016/j.scitotenv.2021.149225
.
Jacobsen
K. H.
&
Koopman
J. S.
2004
Declining hepatitis A seroprevalence: a global review and analysis
.
Epidemiology & Infection
132
(
6
),
1005
1022
.
Kohnen
W.
,
Teske-Keiser
S.
,
Meyer
H.-G.
,
Loos
A. H.
,
Pietsch
M.
&
Jansen
B.
2005
Microbiological quality of carbonated drinking water produced with in-home carbonation systems
.
International Journal of Hygiene and Environmental Health
208
(
5
),
415
423
.
Lévesque
B.
,
Simard
P.
,
Gauvin
D.
,
Gingras
S.
,
Dewailly
E.
&
Letarte
R.
1994
Comparison of the microbiological quality of water coolers and that of municipal water systems
.
Applied and Environmental Microbiology
60
(
4
),
1174
1178
.
Levy
K.
,
Smith
S. M.
&
Carlton
E. J.
2018
Climate change impacts on waterborne diseases: moving toward designing interventions
.
Current Environmental Health Reports
5
(
2
),
272
282
.
Epub 2018/05/04. PubMed PMID: 29721700; PubMed Central PMCID: PMCPMC6119235. doi: 10.1007/s40572-018-0199-7
.
Liguori
G.
,
Cavallotti
I.
,
Arnese
A.
,
Amiranda
C.
,
Anastasi
D.
&
Angelillo
I.
2010
Microbiological quality of drinking water from dispensers in Italy
.
BMC Microbiology
10
,
19
.
doi: 10.1186/1471-2180-10-19. PubMed PMID: 20102613
.
Liu
H.
,
Whitehouse
C.
&
Li
B.
2018
Presence and persistence of salmonella in water: the impact on microbial quality of water and food safety
.
Front Public Health
6
,
159
.
PubMed PMID: 29900166. doi: 10.3389/fpubh.2018.00159
.
Luby
S.
,
Halder
A.
,
Huda
T.
,
Unicomb
L.
,
Islam
M.
&
Arnold
B.
2015
Microbiological contamination of drinking water associated with subsequent child diarrhea
.
Am J Trop Med Hyg.
93
(
5
),
904
911
.
Epub 2015/10/05. https://doi.org/10.4269/ajtmh.15-0274 PMID: 26438031
.
Madison
C.
2019
Rural America's Drinking Water Crisis Chicago
.
AmericanBarAssociation
.
Masood
Z.
,
Rehman
H.
,
Baloch
A.
,
Akbar
N.
,
Zakir
M.
,
Gul
I.
,
Jamil
N.
,
Din
N.
,
Bibi
A.
,
Shahid
I.
,
Ahmad
T.
,
Shah
T.
,
Masab
M.
&
Haseeb
A.
2015
Analysis of physicochemical parameters of water and sediments collected from Rawal Dam Islamabad
.
American-Eurasian Journal of Toxicological Sciences
7
(
3
),
123
128
.
Muhammad
M. S.
,
Abdul-Wahab
M. F.
,
Saidin
M. A. R.
,
Asraf
M. H.
&
Malek
N. A. N. N.
2020
Microbiological analysis of drinking water from water vending machines
.
Malaysian Journal of Fundamental and Applied Sciences
16
(
2
),
186
189
.
Park
M.
2010
Soda Fountains Contained Fecal Bacteria, Study Found
.
CNN
,
Atlanta, GA, USA
.
Patel
A. I.
,
Grummon
A. H.
,
Hampton
K. E.
,
Oliva
A.
,
McCulloch
C. E.
&
Brindis
C. D.
2016
A trial of the efficacy and cost of water delivery systems in San Francisco Bay area middle schools, 2013
.
Preventing Chronic Disease
13
,
E88-E
.
doi:10.5888/pcd13.160108. PubMed PMID: 27390074
.
Phiri
B. J.
,
French
N. P.
,
Biggs
P. J.
,
Stevenson
M. A.
,
Reynolds
A. D.
,
Garcia
R. J.
&
Hayman
D. T. S.
2021
Microbial contamination in drinking water at public outdoor recreation facilities in New Zealand
.
Journal of Applied Microbiology
130
(
1
),
302
312
.
Epub 2020/07/09. PubMed PMID: 32639595. doi: 10.1111/jam.14772
.
Pierce
G.
&
Jimenez
S.
2015
Unreliable water access in U.S. mobile homes: evidence from the American housing survey
.
House Policy Debate
25
(
4
),
739
753
.
doi: 10.1080/10511482.2014.999815
.
Pueblo Unido Community Development Corporation
2020
Building Sustainable Communities in the Eastern Coachella Valley
.
Pueblo Unido Community Development Corporation
,
La Quinta, CA, USA
.
[cited 2020 Nov 25]. Available from: https://pucdc.org/
Quast
C.
,
Pruesse
E.
,
Yilmaz
P.
,
Gerken
J.
,
Schweer
T.
,
Yarza
P.
&
Glöckner
F. O.
2012
The SILVA ribosomal RNA gene database project: improved data processing and web-based tools
.
Nucleic Acids Research
41
(
D1
),
D590
D5D6
.
doi: 10.1093/nar/gks1219
.
Ramírez-Castillo
F. Y.
,
Loera-Muro
A.
,
Jacques
M.
,
Garneau
P.
,
Avelar-González
F. J.
,
Harel
J.
&
Guerrero-Barrera
A. L.
2015
Waterborne pathogens: detection methods and challenges
.
Pathogens
4
(
2
),
307
334
.
Roșca
O. M.
,
Dippong
T.
,
Marian
M.
,
Mihali
C.
,
Mihalescu
L.
,
Hoaghia
M.-A.
&
Jelea
M.
2020
Impact of anthropogenic activities on water quality parameters of glacial lakes from Rodnei mountains, Romania
.
Environmental Research
182
,
109136
.
Roy
P. K.
,
Ha
A. J.
,
Mizan
M. F. R.
,
Hossain
M. I.
,
Ashrafudoulla
M.
,
Toushik
S. H.
&
Ha
S. D.
2021
Effects of environmental conditions (temperature, pH, and glucose) on biofilm formation of Salmonella enterica serotype Kentucky and virulence gene expression
.
Poultry Science
100
(
7
),
101209
.
Epub 2021/06/06. PubMed PMID: 34089933; PubMed Central PMCID: PMCPMC8182266. doi: 10.1016/j.psj.2021.101209
.
Sacchetti
R.
,
De Luca
G.
,
Dormi
A.
,
Guberti
E.
&
Zanetti
F.
2014
Microbial quality of drinking water from microfiltered water dispensers
.
International Journal of Hygiene and Environmental Health
217
(
2–3
),
255
259
.
Szymanska
J.
2003
Biofilm and dental unit waterlines
.
Annals of Agricultural and Environmental Medicine
10
(
2
),
151
157
.
U.S. Geological Survey
.
2019
pH and Water
.
U.S. Geological Survey
,
Washington, DC
.
U.S. Environmental Protection Agency
2021
Revised Total Coliform Rule And Total Coliform Rule
.
U.S. Environmental Protection Agency
,
Washington, DC, USA
.
U.S. Environmental Protection Agency
2021
Drinking Water Regulations and Contaminants
.
EPA
,
Washington, DC, USA
, p.
1
.
Washington State Department of Health
2016
Coliform Bacteria and Drinking Water
.
Washington State
.
Wei
Z.
,
Simin
L.
&
Fengbing
T.
2013
Characterization of urban runoff pollution between dissolved and particulate phases
.
The Scientific World Journal
2013
,
1
6
.
Wei
L.
,
Wu
Q.
,
Zhang
J.
,
Guo
W.
,
Chen
M.
,
Xue
L.
,
Wang
J.
&
Ma
L.
2017
Prevalence and genetic diversity of Enterococcus faecalis isolates from mineral water and spring water in China
.
Frontiers in Microbiology
8
,
1109
.
Epub 2017/07/04. PubMed PMID: 28670302; PubMed Central PMCID: PMCPMC5472655. doi: 10.3389/fmicb.2017.01109
.
Whiley
H.
,
van den Akker
B.
,
Giglio
S.
&
Bentham
R.
2013
The role of environmental reservoirs in human campylobacteriosis
.
Int. J. Environ. Res. Public Health
10
(
11
),
5886
907
.
https://doi.org/10.3390/ijerph10115886 PMID: 24217177
.
White
A. S.
,
Godard
R. D.
,
Belling
C.
,
Kasza
V.
&
Beach
R. L.
2010
Beverages obtained from soda fountain machines in the U.S. contain microorganisms, including coliform bacteria
.
International Journal of Food Microbiology
137
(
1
),
61
66
.
https://doi.org/10.1016/j.ijfoodmicro.2009.10.031
.
Wingender
J.
&
Flemming
H.-C.
2011
Biofilms in drinking water and their role as reservoir for pathogens
.
International Journal of Hygiene and Environmental Health
214
(
6
),
417
423
.
https://doi.org/10.1016/j.ijheh.2011.05.009
.
World Health Organization (WHO)
2017
Guidelines for Drinking-Water Quality: Fourth Edition Incorporating the First Addendum
.
World Health Organization
,
Geneva, Switzerland
.
[updated April 24; cited 2020]. fourth edition incorporating the first addendum. Available from: https://www.who.int/publications/i/item/9789241549950
World Health Organization (WHO)
2022
Drinking-Water Geneva
.
WHO, Geneva, Switzerland
.
[updated Mar 21 2022; cited 2022 4 Apr 2022]. Available from: https://www.who.int/news-room/fact-sheets/detail/drinking-water.
Zanetti
F.
,
De Luca
G.
&
Sacchetti
R.
2009
Control of bacterial contamination in microfiltered water dispensers (MWDs) by disinfection
.
International Journal of Food Microbiology
128
(
3
),
446
452
.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).