The Paris Metropolitan area, which contains over eight million inhabitants, has a daily output of about 3 M cu.meters of wastewater, the purification of which is achieved by SIAAP (Paris Metropolitan Area Sewage Service) in both Achères and Valenton plants. The carbon pollution is eliminated from over 2 M cu.m/day at Achères. In order to improve the quality of output water, its tertiary nitrification in fixed-bed reactors has been contemplated. The BIOFOR (Degremont) and BIOCARBONE (OTV) processes could be tested in semi-industrial pilot reactors at the CRITER research center of SIAAP. At a reference temperature of 13°C, the removed load is approximately 0.5 kg N NH4/m3.day. From a practical point of view, it may be asserted that in such operating conditions as should be at the Achères plant, one cubic meter of filter can handle the tertiary nitification of one cubic meter of purified water per hour at an effluent temperature of 13°C.
Skip Nav Destination
Article navigation
Research Article|
January 01 1990
Tertiary Nitrification Pilot Plants on Parisian Waste Water
Water Sci Technol (1990) 22 (1-2): 347–352.
Citation
C. Paffoni, B. Védry, M. Gousailles; Tertiary Nitrification Pilot Plants on Parisian Waste Water. Water Sci Technol 1 January 1990; 22 (1-2): 347–352. doi: https://doi.org/10.2166/wst.1990.0159