Changes in water quality in sewers may have significant effects on the performance of treatment plants. Experiments have been carried out in two pilot scale sewers for studies of biofilm growth and changes of water quality with anoxic (dosage of nitrate) and anaerobic (septic) conditions, respectively. The thickness of the biofilm in the anoxic sewer was 1-2 mm as compared to 0.3-0.6 mm in the septic sewer at a water velocity of 0.5 m/s. An increase in the water velocity from 0.002 m/s to 0.5 m/s gave thicker and denser biofilms. Sulphide formation was prevented in the anoxic sewer, and influent sulphide was efficiently removed. The denitrification rate in the anoxic sewer was 3.5-4.3 g NO3-N/m2d (15°C). This gave a considerable reduction in both organic matter and phosphorus and an increase in pH and alkalinity. The potential to remove organic matter in sewers may be exploited as a pre-treatment to mechanical and chemical treatment plants in order to meet more stringent effluent standards for organic matter discharge. Removal of readily biodegradable organic matter in the sewer may, however, be a disadvantage for treatment plants based on pre-denitrification. A reduced phosphate concentration may give a reduced metal coagulant dose at chemical treatment plants, whereas an increase in pH and alkalinity may give an increased dose. In the septic sewer, there was a small reduction in the organic matter, but no significant net change in total phosphorus, pH and alkalinity on average. The production rate of sulphide was in the range of 0.3-0.7 gS/m2d (15°C). On average there was no change in the concentration of suspended solids in either of the sewers. A sporadic large sloughing of biofilm was observed, particularly in situations with a very diluted wastewater. Sporadic high concentrations of suspended solids may cause separation problems at treatment plants.
Skip Nav Destination
Article navigation
Research Article|
July 01 1997
A comparison of biofilm growth and water quality changes in sewers with anoxic and anaerobic (septic) conditions
Anette Æsøy;
Anette Æsøy
*HydroCare, Norsk Hydro ASA, N-0240 Oslo, Norway
Search for other works by this author on:
Målfrid Storfjell;
Målfrid Storfjell
**NTNU, Department of Hydraulic and Environmental Engineering, N-7034 Trondheim, Norway
Search for other works by this author on:
Lovisa Mellgren;
Lovisa Mellgren
*HydroCare, Norsk Hydro ASA, N-0240 Oslo, Norway
Search for other works by this author on:
Herman Helness;
Herman Helness
***SINTEF, Civil and Environmental Engineering, Department of Water and Wastewater Treatment, N-7034 Trondheim, Norway
Search for other works by this author on:
Gøril Thorvaldsen;
Gøril Thorvaldsen
***SINTEF, Civil and Environmental Engineering, Department of Water and Wastewater Treatment, N-7034 Trondheim, Norway
Search for other works by this author on:
Hallvard Ødegaard;
Hallvard Ødegaard
**NTNU, Department of Hydraulic and Environmental Engineering, N-7034 Trondheim, Norway
Search for other works by this author on:
Greta Bentzen
Greta Bentzen
*HydroCare, Norsk Hydro ASA, N-0240 Oslo, Norway
Search for other works by this author on:
Water Sci Technol (1997) 36 (1): 303–310.
Citation
Anette Æsøy, Målfrid Storfjell, Lovisa Mellgren, Herman Helness, Gøril Thorvaldsen, Hallvard Ødegaard, Greta Bentzen; A comparison of biofilm growth and water quality changes in sewers with anoxic and anaerobic (septic) conditions. Water Sci Technol 1 July 1997; 36 (1): 303–310. doi: https://doi.org/10.2166/wst.1997.0068
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.915
CiteScore 3.4 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021
33
Views
26
Citations