Detailed measurements of effluent dilution and dispersion were completed in 1995 in the Fraser River estuary, Canada, as part of a larger study to design an environmental effects monitoring program. Wastewater is discharged at rates of 4-9 m3/s through an 18-port, 3-barrel diffuser in about 10 m of water in a tidal estuary 24 km upstream of the mouth. Rhodamine WT dye was used as a tracer and coordinated in situ measurements were carried out using a towed fluorometer system and a profiling system, each operated from separate vessels. Dispersion measurements were obtained for high and low river discharge conditions and for the complete tidal cycle. The surveying methods proved to be effective for both weak and strong current conditions. It was found that vertical mixing was rapid in the unstratified portion of the estuary and usually complete within 200-500 m of the diffuser. Lateral mixing was relatively slow and cross-channel mixing was not observed even at distances exceeding 12 km. Maximum intertidal zone exposure to effluent occurred on ebb tides but at low concentrations (dilution > 300:1) and confined to the north bank of the river. Minimum dilutions, of the order of 5:1 to 10:1, were found over the outfall at slack tide as the current reversed.
Skip Nav Destination
Article navigation
Research Article|
November 01 1998
Wastewater dispersion measurements in the Fraser River estuary, Canada, for the Annacis Island Wastewater treatment plant outfall Available to Purchase
D. O. Hodgins;
D. O. Hodgins
*Seaconsult Marine Research Ltd, 8805 Osler Street, Vancouver, V6P 4G1, Canada
Search for other works by this author on:
R. E. Corbett;
R. E. Corbett
**Associated Engineering (BC) Ltd, 4940 Canada Way, Burnaby, BC, V5G 4M5, Canada
Search for other works by this author on:
D. S. Parker;
D. S. Parker
***Brown and Caldwell Consulting Engineers, 3480 Buskirk Avenue, Pleasant Hill, CA 94523-4342, USA
Search for other works by this author on:
W. K. Faisst;
W. K. Faisst
***Brown and Caldwell Consulting Engineers, 3480 Buskirk Avenue, Pleasant Hill, CA 94523-4342, USA
Search for other works by this author on:
J. R. Ellis
J. R. Ellis
†Greater Vancouver Regional District, 4330 Kingsway, Burnaby, BC, V5H 4G8, Canada
Search for other works by this author on:
Water Sci Technol (1998) 38 (10): 293–300.
Citation
D. O. Hodgins, R. E. Corbett, D. S. Parker, W. K. Faisst, J. R. Ellis; Wastewater dispersion measurements in the Fraser River estuary, Canada, for the Annacis Island Wastewater treatment plant outfall. Water Sci Technol 1 November 1998; 38 (10): 293–300. doi: https://doi.org/10.2166/wst.1998.0414
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00