Coagulant dosing is one of the major operation costs in water treatment plant, and conventional control of this process for most plants is generally determined by the jar test. However, this method can only provide periodic information and is difficult to apply to automatic control. This paper presents the feasibility of applying artificial neural network (ANN) to automatically control the coagulant dosing in water treatment plant. Five on-line monitoring variables including turbidity (NTUin), pH (pHin) and conductivity (Conin) in raw water, effluent turbidity (NTUout) of settling tank, and alum dosage (Dos) were used to build the coagulant dosing prediction model. Three methods including regression model, time series model and ANN models were used to predict alum dosage. According to the result of this study, the regression model performed a poor prediction on coagulant dosage. Both time-series and ANN models performed precise prediction results of dosage. The ANN model with ahead coagulant dosage performed the best prediction of alum dosage with a R2 of 0.97 (RMS=0.016), very low average predicted error of 0.75 mg/L of alum were also found in the ANN model. Consequently, the application of ANN model to control the coagulant dosing is feasible in water treatment.
Skip Nav Destination
Article navigation
Research Article|
August 01 2000
Application of artificial neural network to control the coagulant dosing in water treatment plant
R.-F. Yu;
R.-F. Yu
*Department of Safety, Health and Environmental Engineering, National Lien-Ho Institute of Technology, Miao-Li, 360, Taiwan
Search for other works by this author on:
S.-F. Kang;
S.-F. Kang
**Department of Water Resource and Environmental Engineering, Tamkang University, Taipei, Taiwan
Search for other works by this author on:
S.-L. Liaw;
S.-L. Liaw
***Graduate Institute of Environmental Engineering, National Central University, Chung-li 320, Taiwan
Search for other works by this author on:
M.-c. Chen
M.-c. Chen
**Department of Water Resource and Environmental Engineering, Tamkang University, Taipei, Taiwan
Search for other works by this author on:
Water Sci Technol (2000) 42 (3-4): 403–408.
Citation
R.-F. Yu, S.-F. Kang, S.-L. Liaw, M.-c. Chen; Application of artificial neural network to control the coagulant dosing in water treatment plant. Water Sci Technol 1 August 2000; 42 (3-4): 403–408. doi: https://doi.org/10.2166/wst.2000.0410
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00