The objective of this paper is to apply a closed-loop identification to actual dissolved oxygen control system in the coke wastewater treatment plant. It approximates the dissolved oxygen dynamics to a high order model using the integral transform method and reduces it to the first-order plus time delay (FOPTD) or second-order plus time delay (SOPTD) for the PID controller tuning. To experiment the process identification on the real plant, a simple set-point change of the speed of surface aerator under the closed-loop control without any mode change was used as an activation signal of the identification. The full-scale experimental results show a good identification performance and a good tracking ability for set-point change. As a result of improved control performance, the fluctuation of dissolved oxygen concentration variation has been decreased and the electric power saving has been accomplished.
Skip Nav Destination
Article navigation
Research Article|
April 01 2001
Closed-loop identification and control application for dissolved oxygen concentration in a full-scale coke wastewater treatment plant
C. K. Yoo;
C. K. Yoo
1Department of Chemical Engineering, Automation Research Center, Pohang University of Science and Technology, San 31 Hyoja Dong, Pohang, 790-784, Korea
Search for other works by this author on:
J. H. Cho;
J. H. Cho
1Department of Chemical Engineering, Automation Research Center, Pohang University of Science and Technology, San 31 Hyoja Dong, Pohang, 790-784, Korea
Search for other works by this author on:
H. J. Kwak;
H. J. Kwak
1Department of Chemical Engineering, Automation Research Center, Pohang University of Science and Technology, San 31 Hyoja Dong, Pohang, 790-784, Korea
Search for other works by this author on:
S. K. Choi;
S. K. Choi
2Water Protection Research Team, Research Institute of Industrial Science & Technology, 135 Pohang, 790-330, Korea
Search for other works by this author on:
H. D. Chun;
H. D. Chun
2Water Protection Research Team, Research Institute of Industrial Science & Technology, 135 Pohang, 790-330, Korea
Search for other works by this author on:
I. Lee
I. Lee
1Department of Chemical Engineering, Automation Research Center, Pohang University of Science and Technology, San 31 Hyoja Dong, Pohang, 790-784, Korea
Search for other works by this author on:
Water Sci Technol (2001) 43 (7): 207–214.
Citation
C. K. Yoo, J. H. Cho, H. J. Kwak, S. K. Choi, H. D. Chun, I. Lee; Closed-loop identification and control application for dissolved oxygen concentration in a full-scale coke wastewater treatment plant. Water Sci Technol 1 April 2001; 43 (7): 207–214. doi: https://doi.org/10.2166/wst.2001.0426
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 2.430
CiteScore 3.4 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021
35
Views
13
Citations