The overall energy consumption of domestic wastewater treatment plants (WWTPs) increases with treatment efficiency. Approximately 30 to 45 kWh per people equivalent and year is mostly necessary for advanced nitrogen and phosphorus removal, while the aeration contains the main part of approximately 60%. A new process using encapsulated nitrifiers on gel lens beads is introduced to overcome the high energy consumption of aeration. A more selective nitrification process was found at a nitrification rate of between 50 and 60 mg nitrogen per hour and litre reaction volume corresponding to a hydraulic retention time (HRT) of about 30 to 60 minutes while the soluble Chemical Oxygen Demand (COD) removal could be less than 30% depending on operational conditions of the bio-reactor. The latter enables internal use of wastewater's COD for a post denitrification. For the new process the energy consumption as well as total volume of bio-reactor are much less (approximately 30 to 50% for both) than conventional processes due to the low sludge age for COD and nitrate removal and the avoidance of internal wastewater recycle. Therefore, self-sufficient energy operation of domestic WWTPs operating with advanced treatment efficiency could become possible, if energy recovery by anaerobic sludge digestion is included.
Skip Nav Destination
Close
Close
Article navigation
Research Article|
June 01 2003
Pre-nitrification by encapsulated nitrifiers - a possibility for self-sufficient energy operation of domestic WWTPs
M. Sievers;
*CUTEC-Institut GmbH (Clausthal Environment Technology Institute), Leibnizstr. 21+23, 38678 Clausthal-Zellerfeld, Germany
E-mail: michael.sievers@cutec.de
Search for other works by this author on:
K.D. Vorlop;
K.D. Vorlop
**Institute for Technology and Biosystems Engineering, Federal Agricultural Research Centre (FAL), Bundesallee 50, 38116 Braunschweig, Germany
Search for other works by this author on:
J. Hahne;
J. Hahne
**Institute for Technology and Biosystems Engineering, Federal Agricultural Research Centre (FAL), Bundesallee 50, 38116 Braunschweig, Germany
Search for other works by this author on:
M. Schlieker;
M. Schlieker
**Institute for Technology and Biosystems Engineering, Federal Agricultural Research Centre (FAL), Bundesallee 50, 38116 Braunschweig, Germany
Search for other works by this author on:
S. Schäfer
S. Schäfer
*CUTEC-Institut GmbH (Clausthal Environment Technology Institute), Leibnizstr. 21+23, 38678 Clausthal-Zellerfeld, Germany
Search for other works by this author on:
Water Sci Technol (2003) 47 (11): 173–180.
Citation
M. Sievers, K.D. Vorlop, J. Hahne, M. Schlieker, S. Schäfer; Pre-nitrification by encapsulated nitrifiers - a possibility for self-sufficient energy operation of domestic WWTPs. Water Sci Technol 1 June 2003; 47 (11): 173–180. doi: https://doi.org/10.2166/wst.2003.0602
Download citation file:
Close
Citation
M. Sievers, K.D. Vorlop, J. Hahne, M. Schlieker, S. Schäfer; Pre-nitrification by encapsulated nitrifiers - a possibility for self-sufficient energy operation of domestic WWTPs. Water Sci Technol 1 June 2003; 47 (11): 173–180. doi: https://doi.org/10.2166/wst.2003.0602
Download citation file:
Close
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.638
CiteScore 2.9 • Q2
20
Views
0
Citations