UV disinfection has been applied to water treatment in recent years with low-pressure and medium-pressure UV lamps mainly used as the light source. In general, UV disinfection is considered to be inefficient with water of high turbidity because of inhibition of light penetration. Additionally, photoreactivation may be a problem that should be considered in case a disinfected water is discharged to the environment where sunlight causes reactivation. Recently, other types of lamps have been proposed including a flush-type lamp (such as a pulsed-xenon lamp) that emits high energy and wide wavelength intermittently. In this study, the difference between inactivation efficiencies by low-pressure UV (LPUV) and pulsed-xenon (PXe) lamps was investigated using two coliphage types and three strains of Escherichia coli. PXe had a suppressive effect on photoreactivation rate of the E. coli strains even though there was no significant effect on inactivation rate and maximum survival ratio after photoreactivation. PXe also had a benefit when applied to high turbidity waters as no tailing phenomena were observed in the low survival ratio area although it was observed in LPUV inactivation. This efficiency difference was considered to be due to the difference in irradiated wavelength of both lamps.
Skip Nav Destination
Article navigation
Research Article|
February 01 2003
Inactivation differences of microorganisms by low pressure UV and pulsed xenon lamps Available to Purchase
M. Otaki;
*Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo 112-8610, Japan
E-mail: [email protected]
Search for other works by this author on:
A. Okuda;
A. Okuda
*Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo 112-8610, Japan
Search for other works by this author on:
K. Tajima;
K. Tajima
*Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo 112-8610, Japan
Search for other works by this author on:
T. Iwasaki;
T. Iwasaki
*Ochanomizu University, 2-1-1 Otsuka, Bunkyo-ku, Tokyo 112-8610, Japan
Search for other works by this author on:
S. Kinoshita;
S. Kinoshita
**Iwasaki denki co., 1-1 Ichiriyama-cho, Gyouda, Saitama, 361-8505, Japan
Search for other works by this author on:
S. Ohgaki
S. Ohgaki
***University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
Search for other works by this author on:
Water Sci Technol (2003) 47 (3): 185–190.
Citation
M. Otaki, A. Okuda, K. Tajima, T. Iwasaki, S. Kinoshita, S. Ohgaki; Inactivation differences of microorganisms by low pressure UV and pulsed xenon lamps. Water Sci Technol 1 February 2003; 47 (3): 185–190. doi: https://doi.org/10.2166/wst.2003.0193
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00