Lagoon systems achieve good and stable effluent data in regard to organic pollutants, but they charge the receiving waters with relatively high ammonium loads. Therefore an existing lagoon-plant was extended by a vertical flow reed-bed for the special purpose of nitrification. This paper presents the efficiency of the combination plant as well as the possibility to monitor and control the reed-bed operation by the oxidation-reduction potential (ORP). The results show that the combination plant achieved excellent purification results, the average efficiency degrees were 97% for COD, 77% for Ntotal and 94% for the TKN elimination. The ORP in the effluent of the reed bed showed a clear dependence in its characteristic course and its absolute values on the current nitrification performance, the oxygen supply and the hydraulic behaviour of the reed bed. Therefore the ORP is a very good indicator for the state of the reed bed, which ultimately results from the accumulation of a large number of different influencing parameters. As the preservation of aerobic conditions in the reed bed is the crucial prerequisite for a high nitrification performance and for the avoidance of clogging, the ORP thus offers the possibility of immediate operation control.
Skip Nav Destination
Article navigation
Research Article|
September 01 2003
Controlling a combined lagoon/reed bed system using the oxidation-reduction potential (ORP)
K. Kayser;
*Institute for Water Quality and Waste Management, University of Hannover, Welfengarten 1, D-30167 Hannover, Germany (E-mail: kayser@isah.uni-hannover.de; kunst@isah.uni-hannover.de)
E-mail: kayser@isah.uni-hannover.de
Search for other works by this author on:
S. Kunst;
S. Kunst
*Institute for Water Quality and Waste Management, University of Hannover, Welfengarten 1, D-30167 Hannover, Germany (E-mail: kayser@isah.uni-hannover.de; kunst@isah.uni-hannover.de)
Search for other works by this author on:
G. Fehr;
G. Fehr
**F&N Umweltconsult, Lister Meile 27, 30161 Hannover, Germany (E-mail: info@funumweltconsult.de)
Search for other works by this author on:
H. Voermanek
H. Voermanek
***aquaplaner Ingenieurgesellschaft, Zur Bettfedernfabrik 1, 30451 Hannover, Germany (E-mail: info@aquaplaner.de)
Search for other works by this author on:
Water Sci Technol (2003) 48 (5): 167–174.
Citation
K. Kayser, S. Kunst, G. Fehr, H. Voermanek; Controlling a combined lagoon/reed bed system using the oxidation-reduction potential (ORP). Water Sci Technol 1 September 2003; 48 (5): 167–174. doi: https://doi.org/10.2166/wst.2003.0310
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.