This paper presents an evaluation of the process performance of a pilot-scale “fourth generation” downflow hanging sponge (DHS) post-treatment system combined with a UASB pretreatment unit treating municipal wastewater. After the successful operation of the second- and third-generation DHS reactors, the fourth-generation DHS reactor was developed to overcome a few shortcomings of its predecessors. This reactor was designed to further enhance the treatment efficiency and simplify the construction process in real scale, especially for the application in developing countries. Configuration of the reactor was modified to enhance the dissolution of air into the wastewater and to avert the possible clogging of the reactor especially during sudden washout from the UASB reactor. The whole system was operated at a total hydraulic retention time (HRT) of 8 h (UASB: 6 h and DHS: 2 h) for a period of over 600 days.The combined system was able to remove 96% of unfiltered BOD with only 9 mg/L remaining in the final effluent. Likewise, F. coli were removed by 3.45 log with the final count of 103 to 104 MPN/100 ml. Nutrient removal by the system was also satisfactory.
Skip Nav Destination
Article navigation
Research Article|
July 01 2005
A low-cost municipal sewage treatment system witha combination of UASB and the “fourth-generation”downflow hanging sponge reactors
M. Tandukar;
M. Tandukar
*Department of Environmental Systems Engineering, Nagaoka University of Technology, Nagaoka, 940-2188, Japan
Search for other works by this author on:
S. Uemura;
S. Uemura
**Department of Civil and Environmental Engineering, Kisarazu National College of Technology, Chiba, Japan
Search for other works by this author on:
I. Machdar;
I. Machdar
*Department of Environmental Systems Engineering, Nagaoka University of Technology, Nagaoka, 940-2188, Japan
Search for other works by this author on:
A. Ohashi;
A. Ohashi
*Department of Environmental Systems Engineering, Nagaoka University of Technology, Nagaoka, 940-2188, Japan
Search for other works by this author on:
H. Harada
H. Harada
*Department of Environmental Systems Engineering, Nagaoka University of Technology, Nagaoka, 940-2188, Japan
Search for other works by this author on:
Water Sci Technol (2005) 52 (1-2): 323–329.
Citation
M. Tandukar, S. Uemura, I. Machdar, A. Ohashi, H. Harada; A low-cost municipal sewage treatment system witha combination of UASB and the “fourth-generation”downflow hanging sponge reactors. Water Sci Technol 1 July 2005; 52 (1-2): 323–329. doi: https://doi.org/10.2166/wst.2005.0534