Coxsackie B3 (CoxB3) virus was used as a virological tracer for an assessment of the efficiency of pathogen removal by several typical physicochemical treatment and chemical disinfection processes, such as coagulation-filtration, ultra-filtration, and disinfection using chlorine and ozone, with regard to the pathogenic quality of the treated domestic wastewater for reuse purposes. The CoxB3 virus was seeded to sterilized secondary effluent to make a raw water of known pathogenic level. After applying the raw water to each treatment or disinfection process, the residual virus in the finished water was concentrated, and virus assay was carried out by the Tissue Culture Infectious Dose technique. TCID50 was used as an indicative parameter of CoxB3 virus in the raw and treated water. Parallel experiments were also conducted to evaluate the effectiveness of each process for the removal of coliform bacteria. It was noticed from the experiment that both coagulation-filtration and ultrafiltration could achieve substantial removal of TCID50 at about the same level (2-log removal). However, the effect of the two processes on the removal of coliform bacteria was much different: 2-log removal by coagulation-filtration and 4 to 5-log removal by ultrafiltration. The TCID50 removal correlates more closely with the removal of turbidity than that of coliform bacteria. Chlorine was found to be effective in coliform removal but almost had no effect on TCID50. As ozone was applied, a high removal of both coliform bacteria and TCID50 could be obtained.
Skip Nav Destination
Article navigation
Research Article|
October 01 2005
Application of a virological tracer method for the assessment of pathogen removal by physicochemical treatment and chemical disinfection
X.C. Wang;
*School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, No 13 Yanta Road, Xi'an 710055, China, (E-mail: [email protected]; [email protected]
E-mail: [email protected]
Search for other works by this author on:
F.G. Qiu;
F.G. Qiu
*School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, No 13 Yanta Road, Xi'an 710055, China, (E-mail: [email protected]; [email protected]
Search for other works by this author on:
X.P. Xue;
X.P. Xue
**Department of Microbiology, The Fourth Military Medical University, No 17. Changle West Road, Xi'an 710032, China, (E-mail: [email protected]; [email protected]
Search for other works by this author on:
X. Lu
X. Lu
**Department of Microbiology, The Fourth Military Medical University, No 17. Changle West Road, Xi'an 710032, China, (E-mail: [email protected]; [email protected]
Search for other works by this author on:
Water Sci Technol (2005) 52 (8): 205–212.
Citation
X.C. Wang, F.G. Qiu, X.P. Xue, X. Lu; Application of a virological tracer method for the assessment of pathogen removal by physicochemical treatment and chemical disinfection. Water Sci Technol 1 October 2005; 52 (8): 205–212. doi: https://doi.org/10.2166/wst.2005.0265
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00