In this paper the development of an extension module to the IWA/COST simulation benchmark to include expert reasoning is presented. This module enables the detection of suitable conditions for the development of settling problems of biological origin (filamentous bulking, foaming and rising sludge) when applying activated sludge control strategies to the simulation benchmark. Firstly, a flow diagram is proposed for each settling problem, and secondly, the outcome of its application is shown. Results of the benchmark for two evaluated control strategies illustrate that, once applied to the simulation outputs, this module provides supplementary criteria for plant performance assessment. Therefore, simulated control strategies can be evaluated in a more realistic framework, and results can be recognised as more realistic and satisfactory from the point of view of operators and real facilities.
Skip Nav Destination
Article navigation
Research Article|
February 01 2006
Extension of the IWA/COST simulation benchmark to include expert reasoning for system performance evaluation
J. Comas;
*Laboratori d'Enginyeria Química i Ambiental (LEQUiA), Universitat de Girona, Campus Montilivi s/n, E-17071 Girona, Catalonia, Spain
**Department of Industrial Electrical Engineering and Automation (IEA), Lund University, P.O.Box 118, SE-22100 Lund, Sweden
E-mail: quim@lequia.udg.es
Search for other works by this author on:
I. Rodríguez-Roda;
I. Rodríguez-Roda
*Laboratori d'Enginyeria Química i Ambiental (LEQUiA), Universitat de Girona, Campus Montilivi s/n, E-17071 Girona, Catalonia, Spain
Search for other works by this author on:
M. Poch;
M. Poch
*Laboratori d'Enginyeria Química i Ambiental (LEQUiA), Universitat de Girona, Campus Montilivi s/n, E-17071 Girona, Catalonia, Spain
Search for other works by this author on:
K.V. Gernaey;
K.V. Gernaey
**Department of Industrial Electrical Engineering and Automation (IEA), Lund University, P.O.Box 118, SE-22100 Lund, Sweden
Search for other works by this author on:
C. Rosen;
C. Rosen
**Department of Industrial Electrical Engineering and Automation (IEA), Lund University, P.O.Box 118, SE-22100 Lund, Sweden
Search for other works by this author on:
U. Jeppsson
U. Jeppsson
**Department of Industrial Electrical Engineering and Automation (IEA), Lund University, P.O.Box 118, SE-22100 Lund, Sweden
Search for other works by this author on:
Water Sci Technol (2006) 53 (4-5): 331–339.
Citation
J. Comas, I. Rodríguez-Roda, M. Poch, K.V. Gernaey, C. Rosen, U. Jeppsson; Extension of the IWA/COST simulation benchmark to include expert reasoning for system performance evaluation. Water Sci Technol 1 February 2006; 53 (4-5): 331–339. doi: https://doi.org/10.2166/wst.2006.138
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.