The effect of potassium cyanide (KCN) on nitrification processes in municipal wastewater treatment plants was studied by batch nitrification tests, which indicated that nitrification processes tend to be inhibited at a lower KCN concentration than the present discharge standard to sewerage. The experiment of the biosensor using nitrifying bacteria was also conducted for continuous monitoring of nitrification inhibitor in influent wastewater, and demonstrated that the biosensor can detect KCN at as low as EC10 of the abovementioned batch nitrification test. Moreover, to determine the effectiveness of application of the biosensor to avoid the impact of KCN due to an accidental spillage in a sewerage system, KCN was intentionally injected into the experimental models of activated sludge process equipped both with and without the biosensor. The model with the biosensor that could detect KCN could divert the wastewater including KCN to a refuge tank, which resulted in the avoidance of upset of the activated sludge process. On the other hand, the model without the biosensor was upset in the nitrification process due to KCN. Such differences demonstrate the effectiveness of the biosensor applied to countermeasures of an accidental spillage of toxic chemicals to avoid upset of nitrification in municipal wastewater treatment plants.
Skip Nav Destination
Article navigation
Research Article|
February 01 2006
Biosensor-based control of nitrification inhibitor in municipal wastewater treatment plants
Y. Okayasu;
*Water Quality Team, Water Environmental Research Group, Public Works Research Institute, 1–6, Minamihara, Tsukuba City, 305-8516, Japan,
E-mail: okayasu@pwri.co.jp
Search for other works by this author on:
H. Tanaka;
H. Tanaka
**Research Center for Environmental Quality Control, Graduate School of Engineering, Kyoto University, 1–2, yumihama, Ohtsu City, 520-0811, Japan
Search for other works by this author on:
T. Inui;
T. Inui
***Electronic Equipment Technology Laboratory, Fuji Electric Advanced Technology co., Ltd., 1, Fuji-machi, Hino City, 191-8502, Japan
Search for other works by this author on:
Y. Tanaka
Y. Tanaka
***Electronic Equipment Technology Laboratory, Fuji Electric Advanced Technology co., Ltd., 1, Fuji-machi, Hino City, 191-8502, Japan
Search for other works by this author on:
Water Sci Technol (2006) 53 (4-5): 357–366.
Citation
Y. Okayasu, H. Tanaka, T. Inui, Y. Tanaka; Biosensor-based control of nitrification inhibitor in municipal wastewater treatment plants. Water Sci Technol 1 February 2006; 53 (4-5): 357–366. doi: https://doi.org/10.2166/wst.2006.141