A rapid method using the pilot in-line filter to detect any change in coagulation performance was proposed in this study. This method attempted to detect a change in coagulant dosage and mixing intensity by evaluating the filtrate quality of the in-line filter, which took the rapidly mixed water. Since the response time of this method was less than 10 min, it could be valuable to monitor the coagulation performance. The in-line filter was found more useful without underdrain. The in-line filter was more sensitive to a change in filtrate quality without underdrain than with underdrain. A new method, which combines a jar test with the in-line filter, was proposed to determine the coagulant dosage. This method reflected the actual plant situation more accurately than a jar test.
Skip Nav Destination
Article navigation
Research Article|
February 01 2006
Monitoring of coagulation performance and determination of coagulant dosage using a pilot in-line filter
S.G. Kim;
*Busan Water Quality Institute, 421-1, Maeri Sangdong Gimhaisi Kyungnam, Republic of Korea
E-mail: sgkim0822@hanmail.net
Search for other works by this author on:
K.J. Choi;
K.J. Choi
*Busan Water Quality Institute, 421-1, Maeri Sangdong Gimhaisi Kyungnam, Republic of Korea
Search for other works by this author on:
H.J. Son;
H.J. Son
*Busan Water Quality Institute, 421-1, Maeri Sangdong Gimhaisi Kyungnam, Republic of Korea
Search for other works by this author on:
Y.C. Jun;
Y.C. Jun
*Busan Water Quality Institute, 421-1, Maeri Sangdong Gimhaisi Kyungnam, Republic of Korea
Search for other works by this author on:
J.B. Rhee;
J.B. Rhee
**Civil Engineering Department, Pukyong National University, Republic of Korea
Search for other works by this author on:
I.S. Shon;
I.S. Shon
**Civil Engineering Department, Pukyong National University, Republic of Korea
Search for other works by this author on:
Y.D. Lee;
Y.D. Lee
***Civil and Environmental Engineering Department, Cheju National University, Republic of Korea
Search for other works by this author on:
S.H. Kim
S.H. Kim
****Civil Engineering Department, Kyungnam University, Republic of Korea
Search for other works by this author on:
Water Sci Technol (2006) 53 (4-5): 411–417.
Citation
S.G. Kim, K.J. Choi, H.J. Son, Y.C. Jun, J.B. Rhee, I.S. Shon, Y.D. Lee, S.H. Kim; Monitoring of coagulation performance and determination of coagulant dosage using a pilot in-line filter. Water Sci Technol 1 February 2006; 53 (4-5): 411–417. doi: https://doi.org/10.2166/wst.2006.147
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.