An algorithm for the burst detection and location in water distribution networks based on the continuous monitoring of the flow rate at the entry point of the network and the pressure at a number of points within the network is presented. The approach is designed for medium to large bursts with opening times in the order of a few minutes and is suitable for networks of relatively small size, such as district metered areas (DMAs). The burst-induced increase in the inlet flow rate is detected using the modified cumulative sum (CUSUM) change detection test. Based on parameters obtained from the CUSUM test, the burst is simulated at a number of burst candidate locations. The calculated changes in pressure at the pressure monitoring points are then compared to the measured values and the location resulting in the best fit is selected as the burst location. The EPANET steady-state hydraulic solver is utilised to simulate the flows and pressures in the network. A sensitivity-based sampling design procedure is introduced to find the optimal positions for pressure monitoring points. The proposed algorithm is tested on a case study example network and shows potential for burst detection and location in real water distribution systems.
Skip Nav Destination
Article navigation
Research Article|
February 01 2006
Failure monitoring in water distribution networks
D. Misiunas;
*Dept of Industrial Electrical Engineering and Automation, Lund University, PO Box 118, 221 00 Lund, Sweden
E-mail: [email protected]
Search for other works by this author on:
J. Vítkovský;
J. Vítkovský
**Water Assessment, Dept of Natural Resources and Mines, Queensland, Australia
Search for other works by this author on:
G. Olsson;
G. Olsson
*Dept of Industrial Electrical Engineering and Automation, Lund University, PO Box 118, 221 00 Lund, Sweden
Search for other works by this author on:
M. Lambert;
M. Lambert
***School of Civil and Environmental Engineering, University of Adelaide, Adelaide, SA 5005, Australia
Search for other works by this author on:
A. Simpson
A. Simpson
***School of Civil and Environmental Engineering, University of Adelaide, Adelaide, SA 5005, Australia
Search for other works by this author on:
Water Sci Technol (2006) 53 (4-5): 503–511.
Citation
D. Misiunas, J. Vítkovský, G. Olsson, M. Lambert, A. Simpson; Failure monitoring in water distribution networks. Water Sci Technol 1 February 2006; 53 (4-5): 503–511. doi: https://doi.org/10.2166/wst.2006.154
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00