Management of drinking water safety is changing towards an integrated risk assessment and risk management approach that includes all processes in a water supply system from catchment to consumers. However, given the large number of water supply systems in China and the cost of implementing such a risk assessment procedure, there is a necessity to first conduct a strategic screening analysis at a national level. An integrated methodology of risk assessment and screening analysis is thus proposed to evaluate drinking water safety of a conventional water supply system. The violation probability, indicating drinking water safety, is estimated at different locations of a water supply system in terms of permanganate index, ammonia nitrogen, turbidity, residual chlorine and trihalomethanes. Critical parameters with respect to drinking water safety are then identified, based on which an index system is developed to prioritize conventional water supply systems in implementing a detailed risk assessment procedure. The evaluation results are represented as graphic check matrices for the concerned hazards in drinking water, from which the vulnerability of a conventional water supply system is characterized.
Skip Nav Destination
Article navigation
Research Article|
September 01 2007
Integrated risk assessment and screening analysis of drinking water safety of a conventional water supply system
F. Sun;
1Department of Environmental Science & Engineering, Tsinghua University, Beijing, 100084, China (E-mail: [email protected]; [email protected]; [email protected])
E-mail: [email protected]
Search for other works by this author on:
J. Chen;
J. Chen
1Department of Environmental Science & Engineering, Tsinghua University, Beijing, 100084, China (E-mail: [email protected]; [email protected]; [email protected])
Search for other works by this author on:
Q. Tong;
Q. Tong
1Department of Environmental Science & Engineering, Tsinghua University, Beijing, 100084, China (E-mail: [email protected]; [email protected]; [email protected])
Search for other works by this author on:
S. Zeng
S. Zeng
1Department of Environmental Science & Engineering, Tsinghua University, Beijing, 100084, China (E-mail: [email protected]; [email protected]; [email protected])
Search for other works by this author on:
Water Sci Technol (2007) 56 (6): 47–56.
Citation
F. Sun, J. Chen, Q. Tong, S. Zeng; Integrated risk assessment and screening analysis of drinking water safety of a conventional water supply system. Water Sci Technol 1 September 2007; 56 (6): 47–56. doi: https://doi.org/10.2166/wst.2007.583
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00