We tested at full-scale the innovative Focused Pulsed (FP) technology for pre-treating waste sludge in order to improve methane gas production and biosolids reduction in sludge digestion, but without incurring problems of odors, toxicity, and high costs for chemical or energy consumption. FP pre-treatment of a mixture of primary and secondary sludge increased the soluble COD by 160% and DOC 120% over the control. FP pre-treatment of 63% of the input waste sludge increased biogas production by over 40% and reduced biosolids requiring disposal by 30% when compared to the plant baseline. FP pre-treatment also correlated with a shift of the bacterial and archaeal communities. The most significant change was that the acetate-cleaving Methanosaeta became the dominant methanogen. Full FP pre-treatment should increase biogas production and biosolids removal by 60% and 40%, respectively. Full FP pre-treatment should generate energy benefits of at least 2.7 times and as high as 18 times the FP energy input, depending on heat recovery from FP treatment. For a plant treating 76,000 m3/d of wastewater (380 m3-sludge/d), FP treatment should generate an annual economic benefit of approximately $540,000 net of electricity and other operating and maintenance costs. This represents a payback period of three years or less.
Skip Nav Destination
Article navigation
Research Article|
November 01 2008
Full-scale application of focused-pulsed pre-treatment for improving biosolids digestion and conversion to methane
Bruce E. Rittmann;
1Center for Environmental Biotechnology, Biodesign Institute at Arizona State University, 1001 South McAllister Avenue, Tempe AZ 85287-5701, USA
E-mail: rittmann@asu.edu
Search for other works by this author on:
Hyung-sool Lee;
Hyung-sool Lee
1Center for Environmental Biotechnology, Biodesign Institute at Arizona State University, 1001 South McAllister Avenue, Tempe AZ 85287-5701, USA
Search for other works by this author on:
Husen Zhang;
Husen Zhang
1Center for Environmental Biotechnology, Biodesign Institute at Arizona State University, 1001 South McAllister Avenue, Tempe AZ 85287-5701, USA
Search for other works by this author on:
Jared Alder;
Jared Alder
2OpenCEL, 315 Park Avenue 2W, Glencoe, IL 60022 USA
Search for other works by this author on:
James E. Banaszak;
James E. Banaszak
2OpenCEL, 315 Park Avenue 2W, Glencoe, IL 60022 USA
Search for other works by this author on:
Ronald Lopez
Ronald Lopez
3Mesa Northwest Water Reclamation Plant, 960 North Riverview, Mesa AZ 85201, USA
Search for other works by this author on:
Water Sci Technol (2008) 58 (10): 1895–1901.
Citation
Bruce E. Rittmann, Hyung-sool Lee, Husen Zhang, Jared Alder, James E. Banaszak, Ronald Lopez; Full-scale application of focused-pulsed pre-treatment for improving biosolids digestion and conversion to methane. Water Sci Technol 1 November 2008; 58 (10): 1895–1901. doi: https://doi.org/10.2166/wst.2008.547
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00