One of the major operational costs of phosphorus recovery as struvite is the cost of caustic chemical that is added to maintain a desired level of operative pH. A study was conducted at the Lulu Island Wastewater Treatment Plant (LIWWTP), Richmond, BC, using a struvite crystallizer and a cascade stripper designed at the University of British Columbia (UBC). The stripper was tested under different operating conditions to determine the effectiveness of CO2 stripping in increasing the pH of the water matrix and thereby reducing caustic chemical use. This reduction is expected to reduce the operational costs of struvite production. Throughout the project, a high percentage (90%) of phosphorus removal was achieved under each condition. The cascade stripper was very effective in saving caustic usage, ranging from 35% to 86%, depending on the operating conditions. However, the stripper showed relatively poor performance regarding ammonia stripping.