Although ozone disinfection is a well established technology for drinking water treatment, ozone disinfection mechanisms in wastewater are not well understood such that, historically, ozone wastewater disinfection has not been a feasible technology to implement. The HiPOx™ system is an ozone-based pressurized in-vessel system that can be used either as an advanced oxidation reactor or as a highly efficient ozone dissolution system. The pilot-scale HiPOx™ system was temporarily installed at the Dublin San Ramon Services District (DSRSD) Wastewater Treatment Plant in Dublin, California. Detailed bioassay testing was conducted on the pilot reactor between October and December 2007. Tests on benchtop reactors were performed in June and August 2007. Pilot tests on the HiPOx™ reactor located at DSRSD showed that 6.5 log removal of MS2 coliphage was observed at conservative transferred ozone doses of 5 mg/L (contact time of 93 seconds) in microfiltered water, and 7 mg/L (contact time of 50 seconds) in media filtered water. In media filtered water, minimum CT values of 1.0 mg-min/L resulted in non detect total coliform.
Skip Nav Destination
Article navigation
Research Article|
November 01 2008
Ozone disinfection with the HiPOX™ reactor: streamlining an “old technology” for wastewater reuse
Cari Ishida;
Cari Ishida
1Carollo Engineers, 2700 Ygnacio Valley Road, Suite 300, Walnut Creek, CA 94597, USA E-mail: [email protected]; [email protected]
Search for other works by this author on:
Andrew Salveson;
1Carollo Engineers, 2700 Ygnacio Valley Road, Suite 300, Walnut Creek, CA 94597, USA E-mail: [email protected]; [email protected]
E-mail: [email protected]
Search for other works by this author on:
Keel Robinson;
Keel Robinson
2Applied Process Technology Inc., 3333 Vincent Road, Suite 222, Pleasant Hill, CA 94523, USA E-mail: [email protected]; [email protected]
Search for other works by this author on:
Reid Bowman;
Reid Bowman
2Applied Process Technology Inc., 3333 Vincent Road, Suite 222, Pleasant Hill, CA 94523, USA E-mail: [email protected]; [email protected]
Search for other works by this author on:
Shane Snyder
Shane Snyder
3Southern Nevada Water Authority, 1001 S. Valley View Boulevard, Las Vegas, NV 89153, USA E-mail: [email protected]
Search for other works by this author on:
Water Sci Technol (2008) 58 (9): 1765–1773.
Citation
Cari Ishida, Andrew Salveson, Keel Robinson, Reid Bowman, Shane Snyder; Ozone disinfection with the HiPOX™ reactor: streamlining an “old technology” for wastewater reuse. Water Sci Technol 1 November 2008; 58 (9): 1765–1773. doi: https://doi.org/10.2166/wst.2008.548
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00