This article evaluates and compares the actual behavior of 166 full-scale anaerobic and aerobic wastewater treatment plants in operation in Brazil, providing information on the performance of the processes in terms of the quality of the generated effluent and the removal efficiency achieved. The observed results of effluent concentrations and removal efficiencies of the constituents BOD, COD, TSS (total suspended solids), TN (total nitrogen), TP (total phosphorus) and FC (faecal or thermotolerant coliforms) have been compared with the typical expected performance reported in the literature. The treatment technologies selected for study were: (a) predominantly anaerobic: (i) septic tank + anaerobic filter (ST + AF), (ii) UASB reactor without post-treatment (UASB) and (iii) UASB reactor followed by several post-treatment processes (UASB + POST); (b) predominantly aerobic: (iv) facultative pond (FP), (v) anaerobic pond followed by facultative pond (AP + FP) and (vi) activated sludge (AS). The results, confirmed by statistical tests, showed that, in general, the best performance was achieved by AS, but closely followed by UASB reactor, when operating with any kind of post-treatment. The effluent quality of the anaerobic processes ST + AF and UASB reactor without post-treatment was very similar to the one presented by facultative pond, a simpler aerobic process, regarding organic matter.
Skip Nav Destination
Article navigation
Research Article|
January 01 2009
Comparative performance evaluation of full-scale anaerobic and aerobic wastewater treatment processes in Brazil
M. von Sperling;
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Belo Horizonte 30.110-060, Minais Gerais, Brazil E-mail: silvia@desa.ufmg.br
E-mail: marcos@desa.ufmg.br
Search for other works by this author on:
S. C. Oliveira
S. C. Oliveira
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Belo Horizonte 30.110-060, Minais Gerais, Brazil E-mail: silvia@desa.ufmg.br
Search for other works by this author on:
Water Sci Technol (2009) 59 (1): 15–22.
Citation
M. von Sperling, S. C. Oliveira; Comparative performance evaluation of full-scale anaerobic and aerobic wastewater treatment processes in Brazil. Water Sci Technol 1 January 2009; 59 (1): 15–22. doi: https://doi.org/10.2166/wst.2009.841
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.