A new portable analyzer with polymer lab-on-a-chip (LOC) has been designed, fabricated and fully characterized for continuous sampling and monitoring of lead (Pb(II)) in this work. As the working electrodes of the sensor, bismuth (Bi (III)) which allowed the advantage of being more environmentally friendly than traditional mercury drop electrodes was used, while maintaining similar sensitivity and other desirable characteristics. The size of a portable analyzer was 30 cm × 23 cm × 7 cm, and the weight was around 3 kg. The small size gives the advantage of being portable for field use while not sacrificing portability for accuracy of measurement. Furthermore, the autonomous system developed in coordination with the development of new polymer LOC integrated with electrochemical sensors can provide an innovative way to monitor surface waters in an efficient, cost-effective and sustainable manner.
Skip Nav Destination
Article navigation
Research Article|
December 01 2009
Development of a portable analyzer with polymer lab-on-a-chip (LOC) for continuous sampling and monitoring of Pb(II)
A. Jang;
1Department of Civil and Environmental Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: janga@uc.edu; Paul.Biship@UC.edu
E-mail: janga@uc.edu
Search for other works by this author on:
Z. Zou;
Z. Zou
2MicroSystem and BioMEMS Laboratory, Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: zouz@ececs.uc.edu; mackniec@ececs.uc.edu; wup@ececs.uc.edu; Chong.Ahn@UC.edu
Search for other works by this author on:
E. MacKnight;
E. MacKnight
2MicroSystem and BioMEMS Laboratory, Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: zouz@ececs.uc.edu; mackniec@ececs.uc.edu; wup@ececs.uc.edu; Chong.Ahn@UC.edu
Search for other works by this author on:
P. M. Wu;
P. M. Wu
2MicroSystem and BioMEMS Laboratory, Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: zouz@ececs.uc.edu; mackniec@ececs.uc.edu; wup@ececs.uc.edu; Chong.Ahn@UC.edu
Search for other works by this author on:
I. S. Kim;
I. S. Kim
3Department of Environmental Science and Engineering, Gwangju Institute of Science and Technology (GIST), 1 Oryong-dong, Buk-gu, Gwangju, South Korea E-mail: iskim@gist.ac.kr
Search for other works by this author on:
C. H. Ahn;
C. H. Ahn
2MicroSystem and BioMEMS Laboratory, Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: zouz@ececs.uc.edu; mackniec@ececs.uc.edu; wup@ececs.uc.edu; Chong.Ahn@UC.edu
Search for other works by this author on:
P. L. Bishop
P. L. Bishop
1Department of Civil and Environmental Engineering, University of Cincinnati, Cincinnati, OH, USA E-mail: janga@uc.edu; Paul.Biship@UC.edu
Search for other works by this author on:
Water Sci Technol (2009) 60 (11): 2889–2896.
Citation
A. Jang, Z. Zou, E. MacKnight, P. M. Wu, I. S. Kim, C. H. Ahn, P. L. Bishop; Development of a portable analyzer with polymer lab-on-a-chip (LOC) for continuous sampling and monitoring of Pb(II). Water Sci Technol 1 December 2009; 60 (11): 2889–2896. doi: https://doi.org/10.2166/wst.2009.727
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.915
CiteScore 3.3 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021