This paper aims to investigate the influence of some dissolved air flotation (DAF) process variables (specifically: the hydraulic detention time in the contact zone and the supplied dissolved air concentration) and the pH values, as pretreatment chemical variables, on the micro-bubble size distribution (BSD) in a DAF contact zone. This work was carried out in a pilot plant where bubbles were measured by an appropriate non-intrusive image acquisition system. The results show that the obtained diameter ranges were in agreement with values reported in the literature (10–100 μm), quite independently of the investigated conditions. The linear average diameter varied from 20 to 30 μm, or equivalently, the Sauter (d3,2) diameter varied from 40 to 50 μm. In all investigated conditions, D50 was between 75% and 95%. The BSD might present different profile (with a bimodal curve trend), however, when analyzing the volumetric frequency distribution (in some cases with the appearance of peaks in diameters ranging from 90–100 μm). Regarding volumetric frequency analysis, all the investigated parameters can modify the BSD in DAF contact zone after the release point, thus potentially causing changes in DAF kinetics. This finding prompts further research in order to verify the effect of these BSD changes on solid particle removal efficiency by DAF.
Skip Nav Destination
Article navigation
Research Article|
January 01 2010
Characterization of micro-bubble size distribution and flow configuration in DAF contact zone by a non-intrusive image analysis system and tracer tests
R. B. Moruzzi;
1Geoprocessing and Territorial Planning Department (DEPLAN), Geosciences and Mathematics Institute (IGCE) - Paulista State University (UNESP), Rua 10, n° 2527, Santana, Rio Claro 13500-230, SP, Brazil E-mail: rmoruzzi@rc.unesp.br
E-mail: rmoruzzi@rc.unesp.br
Search for other works by this author on:
M. A. P. Reali
M. A. P. Reali
2Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo (EESC-USP), Av Trabalhador Sãocarlense, 400 Centro, São Carlos 13566-590, SP, Brazil E-mail: mapreali@sc.usp.br
Search for other works by this author on:
Water Sci Technol (2010) 61 (1): 253–262.
Citation
R. B. Moruzzi, M. A. P. Reali; Characterization of micro-bubble size distribution and flow configuration in DAF contact zone by a non-intrusive image analysis system and tracer tests. Water Sci Technol 1 January 2010; 61 (1): 253–262. doi: https://doi.org/10.2166/wst.2010.784
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.915
CiteScore 3.3 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021