Considerable concern exists regarding the appearance and effects of trace and ultra trace pollutants in the aquatic environment. In this context, it is necessary to identify relevant hot spot wastewater – such as hospital wastewater – and to implement specific wastewater treatment solutions. Membrane bioreactor (MBR) technology seems to be a suitable pre-treatment approach for the subsequent advanced treatment by high pressure membrane systems such as nanofiltration (NF) and reverse osmosis (RO). This paper is based upon investigations on the first full scale MBR for separate treatment of hospital wastewater in Germany. In this study an NF as well as an RO module for further treatment of the MBR filtrate were tested. The removal efficiencies were assessed using the following target compounds: bezafibrate, bisoprolol, carbamazepine, clarithromycin, ciprofloxacin, diclofenac, ibuprofen, metronidazole, moxifloxacin, telmisartan and tramadol. In summary, the results of this study confirmed that MBR technology followed by an advanced treatment for trace pollutant removal is an adequate approach for specific treatment of hot spot wastewater such as hospital wastewater. In particular, it was shown that – comparing the tested NF and RO – only (a two stage) RO is appropriate to remove pharmaceutical residues from hospital wastewater entirely. The recommended yield of the 2-stage RO is 70% which results in a retentate sidestream of 9%. Our investigations proved that RO is a very efficient treatment approach for elimination of trace pollutants.
Skip Nav Destination
Article navigation
Research Article|
April 01 2010
Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis
S. Beier;
1RWTH Aachen University, Institute of Environmental Engineering (ISA), Mies-van-der-Rohe-Straße 1, 52074 Aachen, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
E-mail: [email protected]
Search for other works by this author on:
S. Köster;
S. Köster
1RWTH Aachen University, Institute of Environmental Engineering (ISA), Mies-van-der-Rohe-Straße 1, 52074 Aachen, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
K. Veltmann;
K. Veltmann
1RWTH Aachen University, Institute of Environmental Engineering (ISA), Mies-van-der-Rohe-Straße 1, 52074 Aachen, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
H. Schröder, Fr.;
H. Schröder, Fr.
1RWTH Aachen University, Institute of Environmental Engineering (ISA), Mies-van-der-Rohe-Straße 1, 52074 Aachen, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
J. Pinnekamp
J. Pinnekamp
1RWTH Aachen University, Institute of Environmental Engineering (ISA), Mies-van-der-Rohe-Straße 1, 52074 Aachen, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
Water Sci Technol (2010) 61 (7): 1691–1698.
Citation
S. Beier, S. Köster, K. Veltmann, H. Schröder, J. Pinnekamp; Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis. Water Sci Technol 1 April 2010; 61 (7): 1691–1698. doi: https://doi.org/10.2166/wst.2010.119
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00