This article evaluates the performance of 10 large scale upflow anaerobic sludge blanket (UASB) sewage treatment plants (STP) located in semi-tropical areas, 7 plants were located in Brazil, 2 in India and 1 in the Middle East. In addition to the UASB, essential functional units of the STP which potentially impact on the UASB are also evaluated. Most grit removal systems were performing adequately, however in one plant very little grit was being removed. This could have serious implications for the performance of the plant as in a relatively short period of time the reactors could become full of grit. The performance results obtained in this study (COD, BOD and TSS removal efficiencies) are compared to the results of recent literature publications and also to the results of some early pilot and full scale studies. The results found here are broadly similar to those result reported in the recent literature but show a lower performance in comparison with the early pilot scale plants. Factors such as improper design, poor operating procedures, insufficient maintenance and the presence of high sulphate concentrations have been identified as the main reasons for the lower performance.
Skip Nav Destination
Article navigation
Research Article|
January 01 2011
Performance review of large scale up-flow anaerobic sludge blanket sewage treatment plants
B. Heffernan;
1Biothane Systems International, Tanthofdreef 21, 2600 GB Delft, The Netherlands. E-mail: [email protected][email protected]
E-mail: [email protected]
Search for other works by this author on:
J. B. van Lier;
J. B. van Lier
2Faculty of Civil Engineering and Geosciences, Department of Water Management, Section Sanitary Engineering, Delft University of Technology, The Netherlands and UNESCO-IHE, Department of Urban Water and Sanitation, Section Sanitary Engineering. E-mail: [email protected]
Search for other works by this author on:
J. van der Lubbe
J. van der Lubbe
1Biothane Systems International, Tanthofdreef 21, 2600 GB Delft, The Netherlands. E-mail: [email protected][email protected]
Search for other works by this author on:
Water Sci Technol (2011) 63 (1): 100–107.
Citation
B. Heffernan, J. B. van Lier, J. van der Lubbe; Performance review of large scale up-flow anaerobic sludge blanket sewage treatment plants. Water Sci Technol 1 January 2011; 63 (1): 100–107. doi: https://doi.org/10.2166/wst.2011.017
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00