The present study takes an interest in the description of the fouling mechanisms by a numerical approach at the microscopic scale. At first, an X-ray tomography has enabled the modelling of the membrane structure for the numerical simulations. Next, for different particle size, a same volume of particles has been sent in the modelled membrane and the final permeability has been computed. Thus, the influence of the particle size on the fouling has been seen. An observation of the particles penetration in the membrane has been realised to detail this influence. The Hermia relations were used in order to determinate the predominant fouling mechanism or the succession of predominant fouling mechanisms. But, without an accurate calculation of the first derivative, it is not possible to define cleanly the predominant fouling mechanism for a low filtered volume. Nevertheless, the perspectives of the local approach with the numerical simulation seem interesting.
Skip Nav Destination
Article navigation
Research Article|
September 01 2011
Simulation of particle capture in a microfiltration membrane
Q. Derekx;
1Laboratoire de Génie Chimique (CNRS – UMR 5503), Université Paul Sabatier, 118, route de Narbonne 31062, Toulouse Cedex 9, France
4Suez Environnement, CIRSEE, Pôle Eau Potable, 38, rue du président Wilson 78230 Le Pecq, France
E-mail: [email protected]
Search for other works by this author on:
P. Bacchin;
P. Bacchin
1Laboratoire de Génie Chimique (CNRS – UMR 5503), Université Paul Sabatier, 118, route de Narbonne 31062, Toulouse Cedex 9, France
Search for other works by this author on:
D. Veyret;
D. Veyret
3European Commission, Joint Research Centre, Institute of Energy, Post Office Box 2, NL-1755ZG Petten, The Nederlands
Search for other works by this author on:
K. Glucina;
K. Glucina
4Suez Environnement, CIRSEE, Pôle Eau Potable, 38, rue du président Wilson 78230 Le Pecq, France
Search for other works by this author on:
P. Moulin
P. Moulin
2Laboratoire de Mécanique, Modélisation et Procédés Propres (CNRS – UMR 6181), Europôle de l'Arbois, BP 80, Bâtiment Laënnec, Hall C 13545 Aix-en-Provence Cedex 04, France
Search for other works by this author on:
Water Sci Technol (2011) 64 (6): 1368–1373.
Article history
Received:
June 28 2010
Accepted:
September 02 2010
Citation
Q. Derekx, P. Bacchin, D. Veyret, K. Glucina, P. Moulin; Simulation of particle capture in a microfiltration membrane. Water Sci Technol 1 September 2011; 64 (6): 1368–1373. doi: https://doi.org/10.2166/wst.2011.349
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00