In order to evaluate the influence of substrate composition on stormwater treatment and hydraulic effectiveness, mesocosm-scale (180 L, 0.17 m2) laboratory rain gardens were established. Saturated (constant head) hydraulic conductivity was determined before and after contaminant (Cu, Zn, Pb and nutrients) removal experiments on three rain garden systems with various proportions of organic topsoil. The system with only topsoil had the lowest saturated hydraulic conductivity (160–164 mm/h) and poorest metal removal efficiency (Cu ≤ 69.0% and Zn ≤ 71.4%). Systems with sand and a sand–topsoil mix demonstrated good metal removal (Cu up to 83.3%, Zn up to 94.5%, Pb up to 97.3%) with adequate hydraulic conductivity (sand: 800–805 mm/h, sand–topsoil: 290–302 mm/h). Total metal amounts in the effluent were <50% of influent amounts for all experiments, with the exception of Cu removal in the topsoil-only system, which was negligible due to high dissolved fraction. Metal removal was greater when effluent pH was elevated (up to 7.38) provided by the calcareous sand in two of the systems, whereas the topsoil-only system lacked an alkaline source. Organic topsoil, a typical component in rain garden systems, influenced pH, resulting in poorer treatment due to higher dissolved metal fractions.
Skip Nav Destination
Article navigation
Research Article|
June 01 2012
Contaminant removal and hydraulic conductivity of laboratory rain garden systems for stormwater treatment
J. F. Good;
J. F. Good
1University of Canterbury, Hydrological and Ecological Engineering, Department of Civil and Natural Resources Engineering, Private Bag 4800, Christchurch 8141, New Zealand
Search for other works by this author on:
A. D. O'Sullivan;
1University of Canterbury, Hydrological and Ecological Engineering, Department of Civil and Natural Resources Engineering, Private Bag 4800, Christchurch 8141, New Zealand
Search for other works by this author on:
D. Wicke;
D. Wicke
1University of Canterbury, Hydrological and Ecological Engineering, Department of Civil and Natural Resources Engineering, Private Bag 4800, Christchurch 8141, New Zealand
Search for other works by this author on:
T. A. Cochrane
T. A. Cochrane
1University of Canterbury, Hydrological and Ecological Engineering, Department of Civil and Natural Resources Engineering, Private Bag 4800, Christchurch 8141, New Zealand
Search for other works by this author on:
Water Sci Technol (2012) 65 (12): 2154–2161.
Article history
Received:
August 29 2011
Accepted:
February 01 2012
Citation
J. F. Good, A. D. O'Sullivan, D. Wicke, T. A. Cochrane; Contaminant removal and hydraulic conductivity of laboratory rain garden systems for stormwater treatment. Water Sci Technol 1 June 2012; 65 (12): 2154–2161. doi: https://doi.org/10.2166/wst.2012.135
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 2.430
CiteScore 3.4 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021
160
Views
10
Citations