The ATV-A-131 guideline and the design approach published in ‘Wastewater Engineering, Treatment and Reuse (WE)’ are widely used for the design of activated sludge plants. They are both based on simplified steady-state assumptions tailored to the boundary conditions of temperate climates. Using design guidelines beyond the designated temperature range may lead to inappropriate results. The objectives of this paper are (1) to summarise temperature relevant differences between ATV-A-131 and WE; (2) to show the related design components; and (3) to demonstrate a procedure for design parameter adaptation for a full-scale activated sludge plant located in a warm climate region. To gain steady-state data required for wastewater treatment plant (WWTP) design according to ATV-A-131 and WE, full-scale plant data were acquired for a period of 6 months as a basis for analyses and adaptation. Mass balances were calculated for the verification of the measurements and for analysing excess sludge production. The two approaches showed relevant temperature related differences. WE default application resulted in lower deviation in the mass balance results for excess sludge production. However, with the adaptation of the heterotrophic decay rates for both approaches and the inert organic and mineral solids fraction additionally for ATV-A-131, a good fit to the observed excess sludge production could be achieved.
Skip Nav Destination
Article navigation
Research Article|
January 01 2013
WWTP design in warm climates – guideline comparison and parameter adaptation for a full-scale activated sludge plant using mass balancing
C. Walder;
C. Walder
1VA TECH WABAG GmbH, Dresdner Str. 87–91, 1200 Vienna, Austria
Search for other works by this author on:
S. Lindtner;
S. Lindtner
3eDAB GmbH, Obere Augartenstr. 18A/5/1, 1020 Vienna, Austria
Search for other works by this author on:
A. Proesl;
A. Proesl
1VA TECH WABAG GmbH, Dresdner Str. 87–91, 1200 Vienna, Austria
Search for other works by this author on:
F. Klegraf;
F. Klegraf
1VA TECH WABAG GmbH, Dresdner Str. 87–91, 1200 Vienna, Austria
Search for other works by this author on:
N. Weissenbacher
2University of Natural Resources and Life Sciences, Muthgasse 18, 1190 Vienna, Austria
E-mail: norbert.weissenbacher@boku.ac.at
Search for other works by this author on:
Water Sci Technol (2013) 67 (1): 224–231.
Article history
Received:
June 05 2012
Accepted:
August 17 2012
Citation
C. Walder, S. Lindtner, A. Proesl, F. Klegraf, N. Weissenbacher; WWTP design in warm climates – guideline comparison and parameter adaptation for a full-scale activated sludge plant using mass balancing. Water Sci Technol 1 January 2013; 67 (1): 224–231. doi: https://doi.org/10.2166/wst.2012.559
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.915
CiteScore 3.3 • Q2
13 days submission to first
decision
1,439,880 downloads in 2021
91
Views
0
Citations