Activated sludge flocs that are carried to the final effluent can significantly decrease the effectiveness of ultraviolet (UV) disinfection of wastewater. This effect is detected in a typical UV dose–response curve, where at higher UV doses there is a decrease in the inactivation rate (tailing). In this study, the effect of activated sludge process conditions on the UV inactivation kinetics of flocs was investigated. The conditions compared were nitrifying vs. non-nitrifying vs. an enhanced biological nutrient removal–University of Cape Town (BNR-UCT) system. The results showed that the flocs generated in the BNR-UCT process were easier to disinfect. The final effluent from the BNR-UCT process also showed improved kinetics of inactivation and reached higher levels of disinfection. The nitrifying system's final effluent had a lower number of initial fecal coliforms, which contributed to reaching higher disinfection levels compared to the non-nitrifying system.
Skip Nav Destination
Article navigation
Research Article|
June 01 2013
UV disinfection of wastewater flocs: the effect of secondary treatment conditions
Y. Azimi;
1Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario, Canada, M5S3E5
E-mail: [email protected]
Search for other works by this author on:
X. Chen;
X. Chen
2Water Science & Technology Directorate, Environment Canada, 867 Lakeshore Road, Burlington, Ontario, Canada
Search for other works by this author on:
D. G. Allen;
D. G. Allen
1Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario, Canada, M5S3E5
Search for other works by this author on:
V. Pileggi;
V. Pileggi
2Water Science & Technology Directorate, Environment Canada, 867 Lakeshore Road, Burlington, Ontario, Canada
Search for other works by this author on:
P. Seto;
P. Seto
2Water Science & Technology Directorate, Environment Canada, 867 Lakeshore Road, Burlington, Ontario, Canada
Search for other works by this author on:
I. G. Droppo;
I. G. Droppo
2Water Science & Technology Directorate, Environment Canada, 867 Lakeshore Road, Burlington, Ontario, Canada
Search for other works by this author on:
R. R. Farnood
R. R. Farnood
1Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, Ontario, Canada, M5S3E5
Search for other works by this author on:
Water Sci Technol (2013) 67 (12): 2719–2723.
Article history
Received:
November 10 2012
Accepted:
February 07 2013
Citation
Y. Azimi, X. Chen, D. G. Allen, V. Pileggi, P. Seto, I. G. Droppo, R. R. Farnood; UV disinfection of wastewater flocs: the effect of secondary treatment conditions. Water Sci Technol 1 June 2013; 67 (12): 2719–2723. doi: https://doi.org/10.2166/wst.2013.148
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00