Directive 2000/60/EC requires the achievement of a ‘good chemical status’ for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli – EC – is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007–2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006–2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely satisfied. Therefore, despite the high organic and industrial load of the considered plant and the need to find an alternative system for chlorine, as chlorine disinfection has been banned in the Veneto region since December 2012, ozone efficiency is not completely satisfactory and other systems such as peracetic or performic acids and UV systems must be considered.
Skip Nav Destination
Article navigation
Research Article|
March 01 2013
Control of dangerous substances in discharges and microbiological abatement: European framework and a case study of an ozone disinfection system
M. Ostoich;
1Veneto Regional Environmental Prevention and Protection Agency (ARPAV), Provincial Department of Venice, via Lissa n. 6, 30171 Mestre-Venezia, Italy
E-mail: [email protected]
Search for other works by this author on:
F. Serena;
F. Serena
2ARPAV, Provincial Department of Treviso, Via Santa Barbara 5/a, 31100 Treviso, Italy
Search for other works by this author on:
L. Falletti;
L. Falletti
3University of Padua, Department of Industrial Engineering, 35131 Padova, Italy
Search for other works by this author on:
A. Fantoni
A. Fantoni
4Eng., SAGIDEP srl, Viale Lombardia, 12 35043 Monselice (PD), Padova, Italy
Search for other works by this author on:
Water Sci Technol (2013) 67 (6): 1238–1246.
Article history
Received:
June 21 2012
Accepted:
October 25 2012
Citation
M. Ostoich, F. Serena, L. Falletti, A. Fantoni; Control of dangerous substances in discharges and microbiological abatement: European framework and a case study of an ozone disinfection system. Water Sci Technol 1 March 2013; 67 (6): 1238–1246. doi: https://doi.org/10.2166/wst.2013.685
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00