The primary method used for boiler water treatment is the addition of chemicals to industrial boilers to prevent corrosion and scaling. The static scale inhibition method was used to evaluate the scale inhibition performance of 1-hydroxyethylidene-1, 1-diphosphonic acid (HEDP). Autoclave static experiments were used to study the corrosion inhibition properties of the main material for industrial boilers (20# carbon steel) with an HEDP additive in the industrial boiler water medium. The electrochemical behavior of HEDP on carbon steel corrosion control was investigated using electrochemical impedance spectroscopy and Tafel polarization techniques. Experimental results indicate that HEDP can have a good scale inhibition effect when added at a quantity of 5 to 7 mg/L at a test temperature of not more than 100 °C. To achieve a high scale inhibition rate, the HEDP dosage must be increased when the test temperature exceeds 100 °C. Electrochemical and autoclave static experimental results suggest that HEDP has a good corrosion inhibition effect on 20# carbon steel at a concentration of 25 mg/L. HEDP is an excellent water treatment agent.
Skip Nav Destination
Article navigation
Research Article|
April 01 2013
Application of 1-hydroxyethylidene-1, 1-diphosphonic acid in boiler water for industrial boilers
Bin Zeng;
Bin Zeng
1Changsha University of Science & Technology, Changsha, Chinese Hunan, China
Search for other works by this author on:
Mao-dong Li;
Mao-dong Li
2Guangzhou Special Pressure Equipment Inspection and Research Institute, Guangzhou, Chinese Guangdong, China
Search for other works by this author on:
Zhi-ping Zhu;
1Changsha University of Science & Technology, Changsha, Chinese Hunan, China
E-mail: [email protected]
Search for other works by this author on:
Jun-ming Zhao;
Jun-ming Zhao
2Guangzhou Special Pressure Equipment Inspection and Research Institute, Guangzhou, Chinese Guangdong, China
Search for other works by this author on:
Hui Zhang
Hui Zhang
2Guangzhou Special Pressure Equipment Inspection and Research Institute, Guangzhou, Chinese Guangdong, China
Search for other works by this author on:
Water Sci Technol (2013) 67 (7): 1544–1550.
Article history
Received:
July 03 2012
Accepted:
November 15 2012
Citation
Bin Zeng, Mao-dong Li, Zhi-ping Zhu, Jun-ming Zhao, Hui Zhang; Application of 1-hydroxyethylidene-1, 1-diphosphonic acid in boiler water for industrial boilers. Water Sci Technol 1 April 2013; 67 (7): 1544–1550. doi: https://doi.org/10.2166/wst.2013.021