Rivers, lakes and the sea were the natural receivers of raw urban waste and storm waters for a long time but the low sustainability of such practice, the increase of population and a renewed environmental sensibility increased researcher interest in the analysis and mitigation of the impact of urban waters on receiving water bodies (RWB). In Europe, the integrated modelling of drainage systems and RWB has been promoted as a promising approach for implementing the Water Framework Directive. A particular interest is given to the fate of pathogens and especially of Escherichia coli, in all the cases in which an interaction between population and the RWB is foreseen. The present paper aims to propose an integrated water quality model involving the analysis of several sewer systems (SS) discharging their polluting overflows on the coast in a sensitive marine environment. From a modelling point of view, the proposed application integrated one-dimensional drainage system models with a complex three-dimensional model analysing the propagation in space and time of E. coli in the coastal marine area. The integrated approach was tested in a real case study (the Acicastello bay in Italy) where data were available both for SS model and for RWB propagation model calibration. The analysis shows a good agreement between the model and monitored data. The integrated model was demonstrated to be a valuable tool for investigating the pollutant propagation and to highlight the most impacted areas.
Skip Nav Destination
Article navigation
Research Article|
September 01 2013
Modelling of E. coli distribution in coastal areas subjected to combined sewer overflows Available to Purchase
Mauro De Marchis;
Mauro De Marchis
1Facoltà di Ingegneria ed Architettura, Università ‘Kore’ di Enna, Cittadella Universitaria, 94100 Enna, Italy
Search for other works by this author on:
Gabriele Freni;
1Facoltà di Ingegneria ed Architettura, Università ‘Kore’ di Enna, Cittadella Universitaria, 94100 Enna, Italy
E-mail: [email protected]
Search for other works by this author on:
Enrico Napoli
Enrico Napoli
2Dipartimento Ingegneria Civile, Ambientale, Aerospaziale, dei Materiali, Università di Palermo, Viale delle Scienze, 90128, Palermo, Italy
Search for other works by this author on:
Water Sci Technol (2013) 68 (5): 1123–1136.
Article history
Received:
March 05 2013
Accepted:
April 23 2013
Citation
Mauro De Marchis, Gabriele Freni, Enrico Napoli; Modelling of E. coli distribution in coastal areas subjected to combined sewer overflows. Water Sci Technol 1 September 2013; 68 (5): 1123–1136. doi: https://doi.org/10.2166/wst.2013.353
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00