Since November 2009, Germany's first full-scale ozonation plant for tertiary treatment of secondary effluent is in continuous operation. A kinetic model was developed and combined with the commercial computational fluid dynamics (CFD) software ANSYS® CFX® to simulate the removal of micropollutants from secondary effluents. Input data like reaction rate constants and initial concentrations of bulk components of the effluent organic matter (EfOM) were derived from experimental batch tests. Additionally, well-known correlations for the mass transfer were implemented into the simulation model. The CFD model was calibrated and validated by full-scale process data and by analytical measurements for micropollutants. The results show a good consistency of simulated values and measured data. Therewith, the validated CFD model described in this study proved to be suited for the application of secondary effluent ozonation. By implementing site-specific ozone exposition and the given reactor geometry the described CFD model can be easily adopted for similar applications.
Skip Nav Destination
Article navigation
Research Article|
September 01 2013
Application of CFD modelling at a full-scale ozonation plant for the removal of micropollutants from secondary effluent
M. Launer;
1Fluid Mechanics, Biochemical and Chemical Engineering, Dortmund University of Technology, Emil-Figge-Str. 70, 44227 Dortmund, Germany
E-mail: Martin.Launer@bci.tu-dortmund.de
Search for other works by this author on:
S. Lyko;
S. Lyko
2Emschergenossenschaft und Lippeverband, Kronprinzenstr. 37, 45128 Essen, Germany
Search for other works by this author on:
H. Fahlenkamp;
H. Fahlenkamp
1Fluid Mechanics, Biochemical and Chemical Engineering, Dortmund University of Technology, Emil-Figge-Str. 70, 44227 Dortmund, Germany
Search for other works by this author on:
P. Jagemann;
P. Jagemann
2Emschergenossenschaft und Lippeverband, Kronprinzenstr. 37, 45128 Essen, Germany
Search for other works by this author on:
P. Ehrhard
P. Ehrhard
1Fluid Mechanics, Biochemical and Chemical Engineering, Dortmund University of Technology, Emil-Figge-Str. 70, 44227 Dortmund, Germany
Search for other works by this author on:
Water Sci Technol (2013) 68 (6): 1336–1344.
Article history
Received:
March 11 2013
Accepted:
May 13 2013
Citation
M. Launer, S. Lyko, H. Fahlenkamp, P. Jagemann, P. Ehrhard; Application of CFD modelling at a full-scale ozonation plant for the removal of micropollutants from secondary effluent. Water Sci Technol 1 September 2013; 68 (6): 1336–1344. doi: https://doi.org/10.2166/wst.2013.378
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 1.915
CiteScore 3.3 • Q2
13 days submission to first
decision