A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.
Skip Nav Destination
Article navigation
Research Article|
October 01 2013
Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing
Rémy Schilperoort;
1Royal HaskoningDHV, PO Box 151, NL-6500 AD, Nijmegen, The Netherlands
E-mail: [email protected]
Search for other works by this author on:
Holger Hoppe;
Holger Hoppe
2Dr. Pecher AG, Klinkerweg 5, D-40699, Erkrath, Germany
Search for other works by this author on:
Cornelis de Haan;
Cornelis de Haan
1Royal HaskoningDHV, PO Box 151, NL-6500 AD, Nijmegen, The Netherlands
Search for other works by this author on:
Jeroen Langeveld
Jeroen Langeveld
1Royal HaskoningDHV, PO Box 151, NL-6500 AD, Nijmegen, The Netherlands
3Delft University of Technology, PO Box 5048, NL-2600 GA, Delft, The Netherlands
Search for other works by this author on:
Water Sci Technol (2013) 68 (8): 1723–1730.
Article history
Received:
October 22 2012
Accepted:
June 07 2013
Citation
Rémy Schilperoort, Holger Hoppe, Cornelis de Haan, Jeroen Langeveld; Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing. Water Sci Technol 1 October 2013; 68 (8): 1723–1730. doi: https://doi.org/10.2166/wst.2013.419
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00