There is currently a need for a simple, accurate and reproducible method that quantifies the amount of dissolved methane in wastewater in order to realize the potential methane that can be recovered and account for any emissions. This paper presents such a method, using gas chromatography with flame ionization detection fitted with a GS-Gas PRO column coupled with a headspace auto sampler. A practical limit of detection for methane of 0.9 mg L−1, with a retention time of 1.24 min, was obtained. It was found that the reproducibility and accuracy of the method increased significantly when samples were collected using an in-house constructed bailer sampling device and with the addition of 100 μL hydrochloric acid (HCl) and 25% sodium chloride (NaCl) and sonication for 30 min prior to analysis. Analysis of wastewater samples and wastewater sludge collected from a treatment facility were observed to range from 12.51 to 15.79 mg L−1 (relative standard deviation (RSD) 8.1%) and 17.56 to 18.67 mg L−1 (RSD 3.4%) respectively. The performance of this method was validated by repeatedly measuring a mid-level standard (n = 8; 10 mg L−1), with an observed RSD of 4.6%.
Skip Nav Destination
Article navigation
Research Article|
July 09 2014
Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater Available to Purchase
D. J. Beale;
1Land and Water, Commonwealth Scientific and Industrial Research Organisation (CSIRO), PO Box 56, Highett VIC 3190, Australia
E-mail: [email protected]
Search for other works by this author on:
G. Tjandraatmadja;
G. Tjandraatmadja
1Land and Water, Commonwealth Scientific and Industrial Research Organisation (CSIRO), PO Box 56, Highett VIC 3190, Australia
Search for other works by this author on:
M. Toifl;
M. Toifl
1Land and Water, Commonwealth Scientific and Industrial Research Organisation (CSIRO), PO Box 56, Highett VIC 3190, Australia
Search for other works by this author on:
N. Goodman
N. Goodman
1Land and Water, Commonwealth Scientific and Industrial Research Organisation (CSIRO), PO Box 56, Highett VIC 3190, Australia
Search for other works by this author on:
Water Sci Technol (2014) 70 (5): 901–908.
Article history
Received:
February 04 2014
Accepted:
June 19 2014
Citation
D. J. Beale, G. Tjandraatmadja, M. Toifl, N. Goodman; Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater. Water Sci Technol 1 September 2014; 70 (5): 901–908. doi: https://doi.org/10.2166/wst.2014.298
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00