Magnetic water treatment (MWT) could be an interesting alternative to chemical treatment to prevent scaling and has been used as an antiscaling treatment for domestic and industrial equipment. A two level-three factor (23) full factorial design was used to evaluate the effects of pH (6–7.5), flow rate (0.54–0.94) and application of a magnetic field on the induction time (IT), total precipitation (TP) rate and homogeneous precipitation (HP) rate of calcium carbonate (CaCO3) scale from hard water. The experimental results and statistical analysis show that the pH, flow rate and interaction between pH and magnetic field have negative effects on IT response. In the case of TP rate response, the magnitude of the main influence is attributed to the magnetic field, followed by pH value and their interaction. Flow rate and pH value have a negative effect on HP rate response, but their interaction has a positive effect. Within these factor ranges, these studied responses predicted by the models were in good agreement with the experimental values. The coefficient of determination (R2) for reduction time, TP ratio and HP ratio were 97.8%, 99.12% and 99.92%, respectively. These results were analyzed statistically using Minitab 15.
Skip Nav Destination
Article navigation
Research Article|
September 05 2014
A comprehensive factorial design study of variables affecting CaCO3 scaling under magnetic water treatment
Fathi Alimi;
1Hail University, College of Science, P.O. Box 2440, 81451 Hail, Kingdom of Saudi Arabia
2Carthage University, Water Researches and Technologies Centre of Borj-Cedria (CERTE), BP 273, 8020 Soliman, Tunisia
E-mail: [email protected]
Search for other works by this author on:
Ali Boubakri;
Ali Boubakri
2Carthage University, Water Researches and Technologies Centre of Borj-Cedria (CERTE), BP 273, 8020 Soliman, Tunisia
Search for other works by this author on:
Mohamed M. Tlili;
Mohamed M. Tlili
2Carthage University, Water Researches and Technologies Centre of Borj-Cedria (CERTE), BP 273, 8020 Soliman, Tunisia
Search for other works by this author on:
Mohamed Ben Amor
Mohamed Ben Amor
2Carthage University, Water Researches and Technologies Centre of Borj-Cedria (CERTE), BP 273, 8020 Soliman, Tunisia
Search for other works by this author on:
Water Sci Technol (2014) 70 (8): 1355–1362.
Article history
Received:
March 18 2014
Accepted:
August 18 2014
Citation
Fathi Alimi, Ali Boubakri, Mohamed M. Tlili, Mohamed Ben Amor; A comprehensive factorial design study of variables affecting CaCO3 scaling under magnetic water treatment. Water Sci Technol 1 October 2014; 70 (8): 1355–1362. doi: https://doi.org/10.2166/wst.2014.377
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00