The anammox-based process ELAN® was started-up in two different sequencing batch reactor (SBR) pilot plant reactors treating municipal anaerobic digester supernatant. The main difference in the operation of both reactors was the dissolved oxygen (DO) concentration in the bulk liquid. SBR-1 was started at a DO value of 0.4 mg O2/L whereas SBR-2 was started at DO values of 3.0 mg O2/L. Despite both reactors working at a nitrogen removal rate of around 0.6 g N/(L d), in SBR-1, granules represented only a small fraction of the total biomass and reached a diameter of 1.1 mm after 7 months of operation, while in SBR-2 the biomass was mainly composed of granules with an average diameter of 3.2 mm after the same operational period. Oxygen microelectrode profiling revealed that granules from SBR-2 where only fully penetrated by oxygen with DO concentrations of 8 mg O2/L while granules from SBR-1 were already oxygen penetrated at DO concentrations of 1 mg O2/L. In this way granules from SBR-2 performed better due to the thick layer of ammonia oxidizing bacteria, which accounted for up to 20% of all the microbial populations, which protected the anammox bacteria from non-suitable liquid media conditions.
Skip Nav Destination
Article navigation
Research Article|
May 19 2015
Influence of dissolved oxygen concentration on the start-up of the anammox-based process: ELAN®
N. Morales;
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
E-mail: [email protected]
Search for other works by this author on:
A. Val del Río;
A. Val del Río
2Department of Chemical Engineering, School of Engineering, University of Santiago de Compostela, Lope Gomez de Marzoa s/n, E-15705 Santiago de Compostela, Spain
Search for other works by this author on:
J. R. Vázquez-Padín;
J. R. Vázquez-Padín
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
Search for other works by this author on:
R. Gutiérrez;
R. Gutiérrez
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
Search for other works by this author on:
R. Fernández-González;
R. Fernández-González
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
Search for other works by this author on:
P. Icaran;
P. Icaran
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
Search for other works by this author on:
F. Rogalla;
F. Rogalla
1FCC Aqualia, Guillarei WWTP, Tui, E-36720, Spain
Search for other works by this author on:
J. L. Campos;
J. L. Campos
2Department of Chemical Engineering, School of Engineering, University of Santiago de Compostela, Lope Gomez de Marzoa s/n, E-15705 Santiago de Compostela, Spain
3Faculty of Engineering and Science, University Adolfo Ibáñez, Avda Padre Hurtado 750, Viña del Mar, Chile
Search for other works by this author on:
R. Méndez;
R. Méndez
2Department of Chemical Engineering, School of Engineering, University of Santiago de Compostela, Lope Gomez de Marzoa s/n, E-15705 Santiago de Compostela, Spain
Search for other works by this author on:
A. Mosquera-Corral
A. Mosquera-Corral
2Department of Chemical Engineering, School of Engineering, University of Santiago de Compostela, Lope Gomez de Marzoa s/n, E-15705 Santiago de Compostela, Spain
Search for other works by this author on:
Water Sci Technol (2015) 72 (4): 520–527.
Article history
Received:
January 26 2015
Accepted:
April 29 2015
Citation
N. Morales, A. Val del Río, J. R. Vázquez-Padín, R. Gutiérrez, R. Fernández-González, P. Icaran, F. Rogalla, J. L. Campos, R. Méndez, A. Mosquera-Corral; Influence of dissolved oxygen concentration on the start-up of the anammox-based process: ELAN®. Water Sci Technol 1 August 2015; 72 (4): 520–527. doi: https://doi.org/10.2166/wst.2015.233
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00