In many cities in Vietnam, wastewater generated in slaughterhouses is normally discharged directly into surface waters without treatment. Management of slaughterhouse wastewater (SHWW) is difficult due to the lack of infrastructure for conveyance to centralized facilities. On-site treatment presents one cost-effective way of managing SHWW compared to mass improvement of infrastructure. This study evaluates the application of an airlift membrane bioreactor (AL-MBR) for on-site treatment of SHWW. The concentrations of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN) and NH4+-N in the simulated SHWW were 1,697 ± 317 mg/L, 891 ± 137 mg/L, 246 ± 65 mg/L and 171 ± 4.2 mg/L, respectively. The mixed-liquor volatile suspended solids in the aerobic and anoxic tanks were maintained at 5,000–6,000 mg/L. Air flow rate and cross flow velocity were maintained at 0.2 L/min and 0.8 m/s, respectively, to keep the trans-membrane pressure (TMP) stable at 0.8 bar and the membrane flux at 15–18 L/m2 h bar (LMH/bar). The removal efficiencies of COD and TN were 95 ± 1.9% and 70 ± 3.3%, respectively, at a hydraulic retention time (HRT) of 2.5 days. This study shows that GL-MBR is a promising on-site solution for SHWW treatment.
Skip Nav Destination
Article navigation
Research Article|
August 31 2016
Performance of airlift MBR for on-site treatment of slaughterhouse wastewater in urban areas of Vietnam Available to Purchase
Anh Tien Do;
1Institute of Meteorology Hydrology and Climate Change, 23/62 Nguyen Chi Thanh, Dongda, Hanoi, Vietnam
E-mail: [email protected]
Search for other works by this author on:
Dung Quang Bach;
Dung Quang Bach
1Institute of Meteorology Hydrology and Climate Change, 23/62 Nguyen Chi Thanh, Dongda, Hanoi, Vietnam
Search for other works by this author on:
Uan Khac Do;
Uan Khac Do
2School of Environmental Science and Technology, Hanoi University of Science and Technology, C10 building, No. 1 Dai Co Viet, Hanoi, Vietnam
Search for other works by this author on:
Ana Prieto;
Ana Prieto
3Department of Civil, Environmental, Geo Engineering, University of Minnesota, 500 Pillsbury Drive S.E., Minneapolis, MN 55455-0116, USA
Search for other works by this author on:
Huynh Thi Lan Huong
Huynh Thi Lan Huong
1Institute of Meteorology Hydrology and Climate Change, 23/62 Nguyen Chi Thanh, Dongda, Hanoi, Vietnam
Search for other works by this author on:
Water Sci Technol (2016) 74 (9): 2245–2251.
Article history
Received:
December 08 2015
Accepted:
August 19 2016
Citation
Anh Tien Do, Dung Quang Bach, Uan Khac Do, Ana Prieto, Huynh Thi Lan Huong; Performance of airlift MBR for on-site treatment of slaughterhouse wastewater in urban areas of Vietnam. Water Sci Technol 14 November 2016; 74 (9): 2245–2251. doi: https://doi.org/10.2166/wst.2016.418
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00