The objective of this study was to evaluate the behaviour of a system comprising an upflow anaerobic sludge blanket reactor followed by activated sludge to treat domestic sewage. The Betim Central sewage treatment plant, Brazil, was designed to treat a mean influent flow of 514 L/s. The study consisted of statistical treatment of monitoring data from the treatment plant covering a period of 4 years. This work presents the concentrations and removal efficiencies of the main constituents in each stage of the treatment process, and a mass balance of chemical oxygen demand (COD) and nitrogen. The results highlight the good overall performance of the system, with high mean removal efficiencies: BOD (biochemical oxygen demand) (94%), COD (91%), ammonia (72%) and total suspended solids (92%). As expected, this system was not effective for the removal of nutrients, since it was not designed for this purpose. The removal of Escherichia coli (99.83%) was higher than expected. There was no apparent influence of operational and design parameters on the effluent quality in terms of organic matter removal, with the exceptions of the BOD load upstream of the aeration tank and the sludge age in the unit. Results suggest that this system is well suited for the treatment of domestic sewage.
Skip Nav Destination
Article navigation
Research Article|
June 20 2017
Performance evaluation of a large sewage treatment plant in Brazil, consisting of an upflow anaerobic sludge blanket reactor followed by activated sludge
Pollyane Diniz Saliba;
Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Av. Antônio Carlos 6627, Escola de Engenharia, Bloco 1- sala 4622, Belo Horizonte 31270-901, Brazil
E-mail: pollyane.saliba@copasa.com.br
Search for other works by this author on:
Marcos von Sperling
Marcos von Sperling
Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Av. Antônio Carlos 6627, Escola de Engenharia, Bloco 1- sala 4622, Belo Horizonte 31270-901, Brazil
Search for other works by this author on:
Water Sci Technol (2017) 76 (8): 2003–2014.
Article history
Received:
February 07 2017
Accepted:
May 02 2017
Citation
Pollyane Diniz Saliba, Marcos von Sperling; Performance evaluation of a large sewage treatment plant in Brazil, consisting of an upflow anaerobic sludge blanket reactor followed by activated sludge. Water Sci Technol 25 October 2017; 76 (8): 2003–2014. doi: https://doi.org/10.2166/wst.2017.284
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00