Greywater management in Ghana receives little or no attention although untreated greywater is associated with environmental and public health risks. This paper assesses greywater characteristics and handling practices among urban households in three selected communities in Kumasi, the second largest city of Ghana. The study involved in-depth surveys (interviews and observations) with 90 households, and collection of 18 greywater samples from nine greywater sources for laboratory analysis. Average greywater generation is 43.36 ± 17 litres per capita per day, equivalent to 36% of average water consumption. Greywater is untreated before disposal (≈99%), and disposal is mainly (89%) into drains and onto streets. Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) levels are high but give very low BOD/COD ratios (0.20 ± 0.07) indicating a very low biodegradability potential. Nutrient levels are high: 12 times (P) and 30 times (N) in excess of standard discharge limits. Other contaminants detected are heavy metals (Fe, Pb, Zn and Cd), microbes (total coliforms, Escherichia coli and Salmonella spp.), and organic micropollutants – benzalkonium chloride, parabens (methyl and propyl), sodium benzoate and hypochlorite – and details of the levels are discussed in the paper. Greywater reuse could be useful for biomass production, but it also presents a challenge and threat to natural biological processes and water sources.

Greywater contains pollutants and will pose health and environmental risks if not properly treated and disposed of. Meanwhile, large volumes of greywater are generated, accounting for 50–80% of residential wastewater (Roesner et al. 2006; Li et al. 2009; Yu et al. 2013; Oron et al. 2014), with potential reuse benefits. In urban areas, greywater reuse could serve as an alternative water source to ease urban water demand (Yu et al. 2013; Oron et al. 2014) and as a source of nutrients for irrigation (Li et al. 2008; Rodda et al. 2011). Already, increasing urban water demand compounded by climate change is resulting in strategies of finding alternative water sources (Rygaard et al. 2011; Ahmed & Arora 2012; Peloso & Morinville 2014). In Ghana, mostly urban area inhabitants are already experiencing water supply shortages (Peloso & Morinville 2014; Nyarko et al. 2016). Greywater reuse is becoming imperative in water-stressed areas of urban Ghana as in other sub-Saharan African countries (Hyde & Maradza 2013). In the sub-Saharan region and other developing countries, proper greywater management is not given any attention (Morel & Diener 2006; Hyde & Maradza 2013). Available figures from the Ghana Statistical Services indicate the existence of only 1–5% improved greywater disposal practices (GSS 2013a), thus implying huge environmental pollution consequences (Allen et al. 2010). The worst affected environmental component could be water bodies which are the main receivers of untreated wastewater in Ghana (Agyei et al. 2011).

Generally, wastewater including greywater is considered as an asset because of the huge reuse potentials for various purposes, including domestic, industrial and agricultural options (Saravanan et al. 2011; Penn et al. 2013; Tiruneh 2014; Chen et al. 2015). However, there are public health concerns associated with reuse (formal and informal) of greywater because of the presence of contaminants such as pathogens, surfactants, boron, metals, endocrine disrupting compounds and xenobiotics (micropollutants) when the wastewater is not (properly) treated (Janzen et al. 2009; Trojan Technologies 2010; Maimon et al. 2014). Meanwhile, in Ghana there is a dearth of knowledge concerning greywater generation rates, characteristics, and existing treatment and/or reuse practices. This paper therefore describes greywater characterization and household management practices using a case study within three communities of the second largest metropolis in Ghana, Kumasi.

Study areas

The study was conducted at Ayigya, Bomso and Kentinkrono, which are urban communities within the Oforikrom Sub-Metro in the Kumasi Metropolis of the Ashanti region, Ghana. Kumasi is the second largest city in Ghana. The housing conditions within the metropolis (city) according to the regional report of the 2010 National Population & Housing Census (GSS 2013b) are: highest proportion of households with pipe-borne water inside dwelling is 42.3%, and 18.4% have access to borehole/protected well water sources; main dwelling units are compound houses (55.2%) and separate houses (15.7%). The study communities have the following populations: 48,419 (Ayigya) 20,053 (Bomso), and 79,230 (Kentinkrono) (GSS 2013b).

Data collection and analysis

The data collection involved household surveys, field data collection and laboratory analyses of greywater samples. The household surveys focused on capturing data related to domestic greywater handling practices, generation rates, existing reuse options, and water and household chemicals consumption. Greywater samples were collected for laboratory analyses to determine the types and levels of contaminants in greywater. Random sampling was used to select 90 households, 30 each from the three communities for questionnaire surveys to capture relevant data pertaining to greywater management practices. Indicative greywater quantification for a day was carried out in eight households, four households each from two communities, Ayigya and Bomso. Quantification was done directly by collecting and measuring greywater from consenting households within houses from morning to evening (5.30 a.m. to 6.30 p.m.). Descriptive and inferential statistics (analysis of variance (ANOVA), one-sample t-test, and Fisher's exact test) were generated from the data using Microsoft Excel and SPSS (IBM SPSS Statistics Software 2012 version 21).

Greywater samples were taken mainly from laundry, bathroom, kitchen, and neighbourhood drains (as composite source) receiving greywater discharges (from about 20 households) within Bomso and Ayigya. In addition, greywater samples were collected from a salon (hair dressing shop) at Bomso. Time composite samples (USEPA 1992) were taken from the neighbourhood drain (composite source): sampling was done manually by collecting 18 aliquots of 100 ml discrete volumes of greywater at 30 minute intervals. Grab sampling was used for greywater from the bathroom, laundry, kitchen and salon (USEPA 1992). The samples were analysed for physicochemical and microbial parameters. The parameters pH and conductivity were all measured in situ. All samples were stored in an ice chest packed with ice cubes below 4 °C and transported to the laboratory within 4 h. Extensive laboratory analyses were carried out to characterize the greywater using Standard Methods for the Examination of Water and Wastewater (1999). Turbidity was measured with a Hanna turbidimeter (HI 93414); total suspended solids (TSS) were measured using the gravimetric method; chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) analyses were done using the open reflux titrimetric and dilution methods respectively; EDTA titrimetric method was used for the determination of Ca, and Mg while an SPSS flame photometer was used for Na. Heavy metals Fe, Pb and Zn were analysed with atomic absorption spectroscopy (Agilent 200 Series). Organic pollutants of methyl and propyl parabens, benzalkonium chloride and sodium benzoate were analysed with high pressure liquid chromatography. Other methods included total Kjeldahl nitrogen, molybdenum blue test for phosphate and Chromocult® Coliform Agar combined with membrane filtration.

Profile of households

The survey targeted more female respondents (Table 1) because they mostly handle issues related to water and wastewater at the household level in the Ghanaian context. The average age of respondents in the three communities was 40 years or above indicating that our interviewees were household members capable of giving valid and useful information. Ayigya and Bomso have the same average household size of five while in Kentinkrono it is four; meanwhile these household sizes are comparable to the regional figure of four (GSS 2013b). There is a stark difference in the average household income, which is also statistically significant from the ANOVA table (p = 0.00 & F = 8.491) (Table 1). Most households interviewed have household toilet facilities, 57–73%, and the rest use public toilets (Table 1). In addition, most of the household toilet facilities were wet systems (i.e. water closets, 59–68%), which could offer opportunity for greywater reuse by toilet flushing. The majority of respondents (70–90%) had household water supply through in-plumbing (33–47%) and yard taps (37–43%). The per capita water consumption levels contrast significantly (p = 0.00 and F = 11.606) in the ANOVA test; Bomso and Kentinkrono have the lowest and highest consumptions, respectively (Table 1).

Table 1

Profile of households involved in the study

ParametersCommunity and distribution of responses
Items of measurementAyigyaBomsoKentinkrono
Gender of respondents Male, n (%) 11 (37%) 9 (30%) 9 (30%) 
Female, n (%) 19 (63%) 21 (70%) 21 (70%) 
Age of respondents Average (years) 45 ± 15 40 ± 14 46 ± 13 
Household size Average 5 ± 2 5 ± 3 4 ± 1 
Household income* Average (GHS/month) 1,460 ± 431 1,060 ± 460 1,517 ± 507 
Toilet access Household facility, n (%) 19 (63%) 17 (57%) 22 (73%) 
Public facility, n (%) 11 (37%) 13 (43%) 8 (27%) 
Household toilet types Water closet, n (%) 13 (68%) 10 (59%) 15 (68%) 
K/VIP, n (%) 6 (32%) 7 (41%) 7 (32%) 
Water access level In-plumbing, n (%) 13 (43%) 10 (33%) 14 (47%) 
Yard tap, n (%) 12 (40%) 11 (37%) 13 (43%) 
Public standpipe, n (%) 5 (17%) 9 (30%) 3 (10%) 
Water consumptiona,Average (lpcdb124 76 159 
Household water cost* Average (GHS/month) 23 12 26 
Water cost: % of total expenditure** More than 3%, n (%) 5 (17%) 6 (20%) 12 (40%) 
Less than 3%, n (%) 25 (83%) 24 (80%) 18 (60%) 
ParametersCommunity and distribution of responses
Items of measurementAyigyaBomsoKentinkrono
Gender of respondents Male, n (%) 11 (37%) 9 (30%) 9 (30%) 
Female, n (%) 19 (63%) 21 (70%) 21 (70%) 
Age of respondents Average (years) 45 ± 15 40 ± 14 46 ± 13 
Household size Average 5 ± 2 5 ± 3 4 ± 1 
Household income* Average (GHS/month) 1,460 ± 431 1,060 ± 460 1,517 ± 507 
Toilet access Household facility, n (%) 19 (63%) 17 (57%) 22 (73%) 
Public facility, n (%) 11 (37%) 13 (43%) 8 (27%) 
Household toilet types Water closet, n (%) 13 (68%) 10 (59%) 15 (68%) 
K/VIP, n (%) 6 (32%) 7 (41%) 7 (32%) 
Water access level In-plumbing, n (%) 13 (43%) 10 (33%) 14 (47%) 
Yard tap, n (%) 12 (40%) 11 (37%) 13 (43%) 
Public standpipe, n (%) 5 (17%) 9 (30%) 3 (10%) 
Water consumptiona,Average (lpcdb124 76 159 
Household water cost* Average (GHS/month) 23 12 26 
Water cost: % of total expenditure** More than 3%, n (%) 5 (17%) 6 (20%) 12 (40%) 
Less than 3%, n (%) 25 (83%) 24 (80%) 18 (60%) 

GHS1 = US$0.26 (2016); *ANOVA, p < 0.001; **Fisher's test, p > 0.05.

aWater consumption includes all domestic water uses as billed; blitres per capita per day.

The cost of water incurred corresponds to the level of consumption by the households. The highest average expenditure on water came from Kentinkrono, which is GHS3 (GHS: Ghanaian cedi; GHS1 = US$0.26) per month more than the amount spent by households of Ayigya but about twice the amount spent by Bomso respondents (Table 1). The results also show that the cost differences are statistically significant (from ANOVA with p < 0.001 and F = 15.145). However, the majority of the households (n = 67, 74%; p = 0.101), although not statistically significant, spent 3% or less of their expenditure on water, indicating that most of the respondents were able to afford their water supply. This is based on the water affordability benchmark of 3% of total household expenditure on water (Fankhauser & Tepic 2005). On toilet use, the majority of respondents (64%, n = 54) had access to their own household toilets. Again, among these household toilets the majority (66%, n = 38) are water closets (a wet sanitation system) and the rest (34%, n = 20) are Kumasi ventilation improved pit latrines (K/VIPs) (a dry sanitation option).

Greywater generation rates

The greywater generation rates are determined from estimation by households and field quantification. The boxplot (Figure 1(a)) shows differences in greywater estimates by households among the three communities. There is statistically significant variation (p = 0.014) between the mean greywater estimates. The basic statistics show the average quantity of greywater in litres per capita/day (lpcd) of 40.42 ± 20.34 (95% confidence interval (CI), 32.82–48) with median 35; 53.01 ± 34.6 (95% CI, 41.2–64.83) with median 45; and 60.11 ± 25 (95% CI, 51.1–69.2) with median 52 for Ayigya, Bomso and Kentinkrono, respectively (Figure 1(a)). Clearly there are wide ranges within and across the communities suggesting that the estimates could be less useful. Although the field quantification is limited to a small number of households (N = 8) from two communities, it could be considered to be more indicative and useful for greywater quantity discharges from households. The ANOVA shows no significant difference (p = 0.954) in the average greywater discharges from the field quantification results (Figure 1(b)) although the ranges differ widely. The average greywater quantities (lpcd) were 43.75 ± 12.5 (95% CI, 23.56–63.64) with median 42.5, and 42.96 ± 22.76 (95% CI, 6.75–79.18) with median 36.43 for Ayigya and Bomso, respectively.
Figure 1

(a) Greywater generation rates based on households' estimates, with ANOVA of F = 4.470 and p = 0.014; (b) greywater generation rates from the field with ANOVA of F = 0.004 and p = 0.954.

Figure 1

(a) Greywater generation rates based on households' estimates, with ANOVA of F = 4.470 and p = 0.014; (b) greywater generation rates from the field with ANOVA of F = 0.004 and p = 0.954.

Close modal

Although obvious, the assumption was that greywater quantity generation rates measured directly from the field are more accurate than estimates given by household surveys. Since no statistically significant differences existed between the means of actual field greywater generation rates, the overall mean (43.36 ± 17 lpcd) was therefore taken as the test (true) value and compared with households' estimates. From the one-sample t-test (Table 2), there is a statistically significant difference between the field measured greywater generation rates and those estimated by households via surveys. The households overestimated the greywater generation rates by an average of about 8 lpcd, and this difference lies between 95% CI of 2–13 lpcd. When the test value is taken as the existing greywater generation rate (43.36 lpcd) for the study communities, the greywater quantity is about 36% of respondents' average water consumption (120 lpcd). This study reveals a higher greywater generation rate than the estimates of 18.8–25 lpcd provided by a recent study (Hyde & Maradza 2013). However, the greywater quantity in the current study represents a fraction (36%) of total water consumption, far below the known levels of 50–80%. This could be due to the limited sample size and/or because there is less greywater quantity generation during weekdays than at weekends. However, the greywater quantity generated in the study sites could be enough for reuse purposes such as toilet and urinal flushing within dwellings and this could reduce water demand by at least 30–38% (Al-Jayyousi 2003; Jefferson et al. 2004; Gisi et al. 2016).

Table 2

One-sample t-test for actual field and households' estimated greywater quantity

Test value = 43.36 lpcd
tdfSig. (2-tailed)Mean difference95% confidence interval of the difference
LowerUpper
2.765 89 0.007 7.8182 2.200 13.436 
Test value = 43.36 lpcd
tdfSig. (2-tailed)Mean difference95% confidence interval of the difference
LowerUpper
2.765 89 0.007 7.8182 2.200 13.436 

Greywater handling practices

The main greywater sources among all respondents were laundry, bathroom and kitchen sources, and mostly these sources are used to define greywater (WHO 2015; Benami et al. 2016). The majority of responding households (62%, n = 56), although not statistically significant (p = 0.795) from the Fisher's test, considered greywater to be a potential alternative source of water if treated. These same respondents claim they reuse greywater at home for various purposes. However, comparatively few respondents (16%, n = 14; p = 0.076) do collect and/or store the greywater before reuse. Greywater reuse has no significant association with collecting and/or storing greywater (p > 0.05). The practices of reuse are more common with laundry sources (57–67%, n = 17–20) but less with bathroom greywater (30%, n = 9 for Bomso only) and no reuse was reported of kitchen greywater. Non-existence of kitchen greywater reuse is probably similar to other studies (Albalawneh & Chang 2015). Meanwhile, some specific greywater reuses reported included mopping/scrubbing (36%, n = 32), flushing toilets (26%, n = 23) and watering lawns (8%, n = 7). None of the households practised greywater irrigation for any edible biomass production except the very few that use greywater to water their lawns.

Also there was an observation of high health risk concerns among respondents; the majority of respondents (67%, n = 60), although not statistically significant (p = 0.750), perceived that it was unsafe to irrigate vegetables (crops) with greywater (Table 3). This perception is legitimate because public health risks of greywater irrigation for edible biomass are widely established (Pinto & Maheshwari 2010; Benami et al. 2016; Cook 2016), especially when greywater is not treated.

Table 3

Perceptions of greywater reuse for vegetable irrigation

Study communitiesDistribution of responses n (%)
ContaminatedDirtyNot healthyPollutedFisher's exact test (p)
Ayigya (n = 18) 5 (28%) 3 (17%) 9 (50%) 1 (6%) 0.610 
Bomso (n = 21) 10 (48%) 5 (24%) 5 (24%) 1 (5%) 
Kentinkrono (n = 21) 7 (33%) 4 (19%) 6 (29%) 4 (19%) 
Overall (N = 60) 22 (37%) 12 (20%) 20 (33%) 6 (10%) 
Study communitiesDistribution of responses n (%)
ContaminatedDirtyNot healthyPollutedFisher's exact test (p)
Ayigya (n = 18) 5 (28%) 3 (17%) 9 (50%) 1 (6%) 0.610 
Bomso (n = 21) 10 (48%) 5 (24%) 5 (24%) 1 (5%) 
Kentinkrono (n = 21) 7 (33%) 4 (19%) 6 (29%) 4 (19%) 
Overall (N = 60) 22 (37%) 12 (20%) 20 (33%) 6 (10%) 

The general greywater disposal practices by multiple responses are: 1% use septic tanks (i.e. improved), 17% use soak pits, and 89% dispose into storm water gutters or drains and onto streets. The disposal practices among responding households are similar to the reports from the 2010 National Population and Housing Census in that more people practise haphazard and unimproved methods of disposal (GSS 2013a). This situation can be partly attributed to the non-existence of sewerage systems (water-borne sanitation) in these areas (Carden et al. 2008) as the whole of Ghana (including the cities) has poor sewerage coverage of less than 5% (Murray & Drechsel 2011).

Characteristics of greywater

The greywater characterization involved assessment of the main use physicochemical and microbial parameters and selected organic micropollutants. The physicochemical qualities are provided in Tables 4 and 5 for the two study sites used. The findings from the two sites are similar when compared against the Ghana Environmental Protection Agency (GEPA) draft guidelines for wastewater discharges (GEPA n.d.). Most greywater discharges from almost all sources are failing according to GEPA standards in almost all parameters. With pH and electrical conductivity (EC), most sources met GEPA standards but one or two discharge sources failed marginally (Tables 4 and 5). Moreover, attention should be given to key parameters such as nutrient (nitrogen and phosphorus) levels and BOD/COD ratio to reduce the impact on the receiving aquatic environment. The higher BOD and COD levels coupled with very low BOD/COD ratios (far less than 0.5, i.e. 0.20 ± 0.07) challenge biodegradation (Kulabako et al. 2011; Boyjoo et al. 2013), especially under natural environmental self-purification conditions. The very low biodegradation observed is similar to studies from Uganda with mean BOD/COD ratio range of 0.13–0.25 (Kulabako et al. 2011), and in low income communities of Accra, Ghana, with BOD/COD ratio of 0.29, but for high and middle income communities the BOD/COD ratios were more than 0.80 (Mohammed et al. 2015). Thus, greywater composition can be highly variable depending on household activities, lifestyle and use of chemicals (Etchepare & van der Hoek 2015). Also, the nutrients are far in excess of the GEPA limits, by 12 times (P) and 30 times (N), signalling caution regarding potential algal bloom and eutrophication in receiving water bodies. However, the nutrient characteristics offer great potential for reuse in irrigation because they fall well within the recommended limits of 2–32 mg/l (N) and 0.6–27 mg/l (P) (Mohamed et al. 2013).

Table 4

Physicochemical parameters of greywater from Bomso

ParameterUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchenSalon
pH – 6–9 7.8 9.1 6.8 8.8 6.4 
EC μS/cm 1,500 1,147 3,530 1,148 3,130 374 
TSS mg/l 50 2,360 3,610 476 4,720 372 
Turbidity NTU 75 386 729 549 528 532 
BOD mg/l 50 248.3 268.5 139.3 269 132.5 
COD mg/l 250 1,510 2,210 400 2,180 580 
BOD/CODw – NA 0.16 0.12 0.35 0.12 0.23 
Total Kjeldahl nitrogen mg/l 1.0b 13.7 12.8 7.7 14.5 8.1 
Mg mg/l NA 1.72 0.52 1.94 5.67 1.74 
Total P mg/l 13.2 12.2 11.3 13 22.6 
ParameterUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchenSalon
pH – 6–9 7.8 9.1 6.8 8.8 6.4 
EC μS/cm 1,500 1,147 3,530 1,148 3,130 374 
TSS mg/l 50 2,360 3,610 476 4,720 372 
Turbidity NTU 75 386 729 549 528 532 
BOD mg/l 50 248.3 268.5 139.3 269 132.5 
COD mg/l 250 1,510 2,210 400 2,180 580 
BOD/CODw – NA 0.16 0.12 0.35 0.12 0.23 
Total Kjeldahl nitrogen mg/l 1.0b 13.7 12.8 7.7 14.5 8.1 
Mg mg/l NA 1.72 0.52 1.94 5.67 1.74 
Total P mg/l 13.2 12.2 11.3 13 22.6 

NA, not available; bammonia level; w0.20 ± 0.09.

Table 5

Physicochemical parameters of greywater from Ayigya

ParametersUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchen
pH – 6–9 8.2 9.6 6.8 9.7 
EC μS/cm 1,500 1,045 351 1,544 863 
TSS mg/l 50 1,820 2,170 440 3,020 
Turbidity NTU 75 378 400 342 204 
BOD mg/l 50 265.3 258.5 205.3 249.5 
COD mg/l 250 1,260 1,410 840 1,860 
BOD/CODw – NA 0.21 0.18 0.24 0.13 
Total Kjeldahl nitrogen mg/l 1.0b 16.3 15.4 23.9 29.5 
Mg mg/l NA 0.33 1.00 0.88 1.05 
Total P mg/l 18.5 23.2 12.5 10.8 
ParametersUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchen
pH – 6–9 8.2 9.6 6.8 9.7 
EC μS/cm 1,500 1,045 351 1,544 863 
TSS mg/l 50 1,820 2,170 440 3,020 
Turbidity NTU 75 378 400 342 204 
BOD mg/l 50 265.3 258.5 205.3 249.5 
COD mg/l 250 1,260 1,410 840 1,860 
BOD/CODw – NA 0.21 0.18 0.24 0.13 
Total Kjeldahl nitrogen mg/l 1.0b 16.3 15.4 23.9 29.5 
Mg mg/l NA 0.33 1.00 0.88 1.05 
Total P mg/l 18.5 23.2 12.5 10.8 

NA, not available; bammonia level; w0.19 ± 0.05.

The findings on heavy metals and microbial loads of the greywater from the two sites are presented in Tables 6 and 7. On the heavy metals content, the greywater from all sources or streams in both study sites contained some metals but their levels met the Ghana standards (GEPA norm), indicating they were safe for environmental discharge. However, greywater discharge must be monitored closely for potential environmental (bio)accumulation and magnification, especially in the case of Pb, the level of which is comparatively closer to the permissible discharge limit (for kitchen and laundry sources, 0.099 and 0.095 mg/l). The metal contamination could originate from detergents and personal care products (Boyjoo et al. 2013). All greywater sources were contaminated with at least one type of the three microbes (total coliforms, Escherichia coli and Salmonella spp.) and their detected loads were far above the GEPA permissible levels for wastewater discharges (Tables 6 and 7). Consistently, E. coli and Salmonella spp. were not found in greywater from kitchen sources and the hairdressing salon source. This suggests that the two sources could not be linked with faecal contamination or cross-contamination, both of which potentially exist with the other greywater sources.

Table 6

Heavy metals and microbes in greywater from Bomso

ParameterUnitGhana EPA guidelinesCompositeLaundryBathroomKitchenSalon
Heavy metals 
 Fe mg/l 10.0 0.22 0.129 0.233 0.355 0.367 
 Pb mg/l 0.1 0.048 0.099 0.087 0.095 0.064 
 Zn mg/l 10.0 0.038 0.044 0.076 0.055 0.044 
 Cd mg/l <0.1 0.001 0.001 0.001 Nil 0.001 
Microbial 
 Total coliforms Log10 cfu/100 ml 2.6 8.2 8.3 7.4 7.9 7.5 
E. coli Log10 cfu/100 ml 1.0 6.5 6.0 6.3 Nil Nil 
Salmonella spp. Log10 cfu/100 ml NA 6.7 6.5 6.5 Nil Nil 
ParameterUnitGhana EPA guidelinesCompositeLaundryBathroomKitchenSalon
Heavy metals 
 Fe mg/l 10.0 0.22 0.129 0.233 0.355 0.367 
 Pb mg/l 0.1 0.048 0.099 0.087 0.095 0.064 
 Zn mg/l 10.0 0.038 0.044 0.076 0.055 0.044 
 Cd mg/l <0.1 0.001 0.001 0.001 Nil 0.001 
Microbial 
 Total coliforms Log10 cfu/100 ml 2.6 8.2 8.3 7.4 7.9 7.5 
E. coli Log10 cfu/100 ml 1.0 6.5 6.0 6.3 Nil Nil 
Salmonella spp. Log10 cfu/100 ml NA 6.7 6.5 6.5 Nil Nil 

NA, not available; Nil, not detected.

Table 7

Heavy metals and microbes in greywater from Ayigya

ParameterUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchen
Metals 
 Fe mg/l 10 0.469 0.236 0.347 0.211 
 Pb mg/l 0.1 0.088 0.034 0.063 0.059 
 Zn mg/l 10 0.099 0.057 0.069 0.068 
 Cd mg/l <0.1 0.001 0.001 0.003 0.001 
Microbial 
 Total coliforms Log10 cfu/100 ml 2.6 7.9 6.3 7.7 6.4 
E. coli Log10 cfu/100 ml 1.0 7.0 5.5 6.0 Nil 
Salmonella spp. Log10 cfu/100 ml NA 6.3 5.0 6.0 Nil 
ParameterUnitsGhana EPA guidelinesCompositeLaundryBathroomKitchen
Metals 
 Fe mg/l 10 0.469 0.236 0.347 0.211 
 Pb mg/l 0.1 0.088 0.034 0.063 0.059 
 Zn mg/l 10 0.099 0.057 0.069 0.068 
 Cd mg/l <0.1 0.001 0.001 0.003 0.001 
Microbial 
 Total coliforms Log10 cfu/100 ml 2.6 7.9 6.3 7.7 6.4 
E. coli Log10 cfu/100 ml 1.0 7.0 5.5 6.0 Nil 
Salmonella spp. Log10 cfu/100 ml NA 6.3 5.0 6.0 Nil 

NA, not available; Nil, not detected.

Presence of organic micropollutants

The presence and the levels of selected organic micropollutants also known as xenobiotic organic compounds are given in Table 8. The findings show that all greywater sources contained benzalkonium chloride (BAK) unlike the other detected contaminants, and this supports the fact that BAK has a wide use in household cleaning products (Barceló 2005). The BAK load has a wide range of 1.2–6.3 mg/l (3.87 ± 2.30) and is actually higher compared with levels reported in literature although it is among the dominant contaminants in greywater (Leal et al. 2010; Gisi et al. 2016). Although the other four contaminants were detected in comparatively fewer greywater sources, their levels were also higher than given in literature and higher than recommended levels. In all instances, sodium hypochlorite (bleach) on average presented the highest contaminant load of 7.4–8 mg/l (7.58 ± 0.29) (Table 8). All these contaminants are commonly used as surfactants, antimicrobial preservatives and antioxidants in cosmetics, toiletries, detergents, pharmaceuticals and food used in homes (Armstrong & Froelich 1964; Eriksson et al. 2003; Brausch & Rand 2011; Błędzka et al. 2014). Their concern to environmentalists is that continuous exposure in the aquatic environment could lead to toxic, oestrogenic, endocrine and carcinogenic effects (Brausch & Rand 2011; Błędzka et al. 2014).

Table 8

Selected organic micropollutants levels from different greywater sources

SiteGreywater sourceBenzalkonium chloride*Sodium benzoateMethyl parabenPropyl parabenSodium hypochlorite
mg/lmg/lmg/lmg/lmg/l
Bomso Salon 6.Nil 1.8 1.3 Nil 
Kitchen 6.Nil Nil Nil Nil 
Bathroom 1.Nil Nil Nil Nil 
Laundry 1.Nil Nil Nil 8.0 
Composite 2.2.6 Nil 0.8 7.4 
Ayigya Kitchen 5.Nil Nil Nil Nil 
Bathroom 6.0.4 Nil Nil Nil 
Laundry 1.Nil 1.6 Nil 7.5 
Composite 2.Nil Nil Nil 7.4 
SiteGreywater sourceBenzalkonium chloride*Sodium benzoateMethyl parabenPropyl parabenSodium hypochlorite
mg/lmg/lmg/lmg/lmg/l
Bomso Salon 6.Nil 1.8 1.3 Nil 
Kitchen 6.Nil Nil Nil Nil 
Bathroom 1.Nil Nil Nil Nil 
Laundry 1.Nil Nil Nil 8.0 
Composite 2.2.6 Nil 0.8 7.4 
Ayigya Kitchen 5.Nil Nil Nil Nil 
Bathroom 6.0.4 Nil Nil Nil 
Laundry 1.Nil 1.6 Nil 7.5 
Composite 2.Nil Nil Nil 7.4 

Nil, not detected; *3.87 ± 2.30 (both sites), 3.80 ± 2.54 (Bomso), 3.95 ± 2.33 (Ayigya).

Advocacy for increased investment in sanitation (greywater included)

There is a need to give more attention to greywater management in Ghana especially in cities and urban areas where large volumes of greywater are generated because of increasing population growth and rapid urbanization. The characteristics of greywater in the current study present serious challenges to natural biological processes and a threat to natural water sources. Meanwhile, greywater has reuse opportunity for biomass production because of its nutrient content, and also water reclamation for non-potable domestic uses to ease urban water supply stress. Households and/or homeowners are not safely managing greywater like blackwater. While provisions exist for onsite treatment systems for blackwater management, there is no consideration for greywater. Currently, there are very limited wastewater treatment plants to receive any greywater streams. For the city of Kumasi, only two suburbs have sewerage systems (only for blackwater), namely Kwame Nkrumah University of Science and Technology, and Asafo (Awuah et al. 2014). These two systems have challenges of over-subscription, abuse and abysmal performance.

One of the reasons for the low investment in wastewater treatment is the perceived high investment cost. Yet, the benefits of sanitation are usually not mentioned. A starting point towards finding a lasting solution is advocacy for increased investment in sanitation (including greywater) based on the benefits, policy support for innovation/appropriate low-cost technologies for different service levels (household, neighbourhood cluster, community or citywide level), setting greywater treatment and reuse standards/guidelines, and promoting local research on technologies and investment planning. For instance, this paper is part of the lead author's ongoing research work on the use of constructed wetlands as an emerging household-level technology for greywater treatment.

The average greywater generation rate from households studied is around 43 lpcd, representing about 36% of the average water consumption. Greywater from laundry and bathrooms is suitable for specific reuses that include floor cleaning/mopping, flushing toilets and watering lawns. Household-level greywater management is abysmal, because there is no treatment before disposal (≈99%), and discharge is largely (89%) by throwing into storm water drains and onto the streets. The greywater sources did not meet most of the key wastewater discharge limits (BOD, COD and nutrients) according to the Ghana Environmental Protection Agency guidelines. The BOD and COD levels are high but the low BOD/COD ratios (the average 0.20 ± 0.07 is far less than 0.5) could limit biodegradation especially under natural biological environmental conditions. The higher nutrient (nitrogen and phosphorus) levels in excesses of the GEPA discharge limits indicate a greater threat to receiving water bodies. Meanwhile, the higher nutrient content offers great reuse potential for irrigation purposes. The greywater sources are contaminated with heavy metals and microbes including total coliforms, E. coli and Salmonella spp. While all greywater sources failed the GEPA microbial limits where detected, the levels of metals (Fe, Pb, Zn and Cd) were within their respective discharge limits. Five micropollutants, BAK, parabens (methyl and propyl), sodium benzoate and hypochlorite, were detected in greywater at levels higher than expected although not extensively detected in all greywater sources except for BAK.

Some benefits could be derived from reuse of the greywater; however, the low biodegradability (BOD/COD ratio) may limit natural biological processes, and without any treatment the greywater may threaten natural water sources. Greywater management in Ghana especially for urban settings needs conscious policy intervention and actions including research on appropriate urban household-level (decentralized) management options.

The authors acknowledge the support of key personnel including Samuel Oppong Bekoe of the Pharmaceutical Chemistry Department (KNUST) and all the laboratory technicians from the EQE laboratory of the Civil Engineering Department (KNUST) for their commitment and hard work. We also acknowledge the support of all survey respondents. The authors declare no conflict of interest.

Agyei
P. A.
Awuah
E.
Oduro-Kwarteng
S.
2011
Faecal sludge management in Madina, Ghana
.
Journal of Applied Technology and Environmental Sanitation
1
(
3
),
239
249
.
Albalawneh
A.
Chang
T.-K.
2015
Review of the greywater and proposed greywater recycling scheme for agricultural irrigation reuses
.
International Journal of Research – Granthaalayah
3
(
12
),
16
35
.
Al-Jayyousi
O. R.
2003
Greywater reuse: towards sustainable water management
.
Desalination
156
,
181
192
.
Allen
L.
Christian-Smith
J.
Palaniappan
M.
2010
Overview of Greywater Reuse: The Potential of Greywater Systems to Aid Sustainable Water Management
.
Pacific Institute
,
California
,
USA
.
Armstrong
J. A.
Froelich
E. J.
1964
Inactivation of viruses by benzalkonium chloride
.
Applied Microbiology
12
(
2
),
132
137
.
Awuah
E.
Amankwaah-Kuffour
R.
Gyasi
S. F.
Lubberding
H. J.
Gijzen
H. J.
2014
Characterization and management of domestic wastewater in two suburbs of Kumasi, Ghana
.
Research Journal of Environmental Sciences
8
(
6
),
318
330
.
Barceló
D.
(ed.)
2005
Estrogens and Progestogens in Wastewater, Sludge, Sediments, and Soil
,
Vol. 2
.
Springer
,
Berlin
,
Germany
.
Błędzka
D.
Gromadzińska
J.
Wąsowicz
W.
2014
Parabens. From environmental studies to human health
.
Environment International
67
,
27
42
.
doi:10.1016/j.envint.2014.02.007
.
Boyjoo
Y.
Pareek
V. K.
Ang
M.
2013
A review of greywater characteristics and treatment processes
.
Water Science & Technology
67
(
7
),
1403
1424
.
doi:10.2166/wst.2013.675
.
Brausch
J. M.
Rand
G. M.
2011
A review of personal care products in the aquatic environment: environmental concentrations and toxicity
.
Chemosphere
82
(
11
),
1518
1532
.
doi:10.1016/j.chemosphere.2010.11.018
.
Carden
K.
Armitage
N.
Winter
K.
Sichone
O.
Rivett
U.
2008
The management of greywater in the non-sewered areas of South Africa
.
Urban Water Journal
5
(
4
),
329
343
.
doi:10.1080/15730620801972316
.
Chen
W.
Bai
Y.
Zhang
W.
Lyu
S.
Jiao
W.
2015
Perceptions of different stakeholders on reclaimed water reuse: the case of Beijing, China
.
Sustainability
7
,
9696
9710
.
doi:10.3390/su7079696
.
Etchepare
R.
van der Hoek
J. P.
2015
Health risk assessment of organic micropollutants in greywater for potable reuse
.
Water Research
72
(
1
),
186
198
.
doi:10.1016/j.watres.2014.10.048
.
Fankhauser
S.
Tepic
S.
2005
Can Poor Consumers pay for Energy and Water? An Affordability Analysis for Transition Countries
.
European Bank Working Paper
.
European Bank for Reconstruction and Development
,
London
,
UK
.
GEPA (Ghana Environmental Protection Agency)
n.d.
General Environmental Quality Standards (Ghana). Draft Regulation
.
GAPA Ashanti Regional Office, Kumasi, Ghana
.
Gisi
S. D.
Casella
P.
Notarnicola
M.
Farina
R.
2016
Grey water in buildings: a mini-review of guidelines, technologies and case studies
.
Civil Engineering and Environmental Systems
33
(
1
),
35
47
.
doi:10.1080/10286608.2015.1124868
.
GSS (Ghana Statistical Service)
2013a
Ghana 2010 Population & Housing Census: Demographic, Social, Economic, Housing, Characteristics
.
Ghana Statistical Service
,
Accra
,
Ghana
.
GSS (Ghana Statistical Service)
2013b
Regional Analytical Report: Ashanti region
. In:
2010 Population and Housing Census Analytical Report
(
Bentsi-Enchill
N.
Gaisie
S. K.
, eds).
Ghana Statistical Service
,
Accra
,
Ghana
.
Hyde
K.
Maradza
E.
2013
An evaluation of the theoretical potential and practical opportunity for using recycled greywater for domestic purposes in Ghana
.
Journal of Cleaner Production
60
,
195
200
.
doi:10.1016/j.jclepro.2013.05.004
.
Janzen
N.
Banzhaf
S.
Scheytt
T.
Bester
K.
2009
Vertical flow soil filter for the elimination of micro pollutants from storm and waste water
.
Chemosphere
77
(
10
),
1358
1365
.
doi:10.1016/j.chemosphere.2009.09.024
.
Jefferson
B.
Palmer
A.
Jeffrey
P.
Stuetz
R.
Judd
S.
2004
Grey water characterisation and its impact on the selection and operation of technologies for urban reuse
.
Water Science & Technology
50
(
2
),
157
164
.
Leal
L. H.
Vieno
N.
Temmink
H.
Zeeman
G.
Buisman
C. J.
2010
Occurrence of xenobiotics in gray water and removal in three biological treatment systems
.
Environmental Science & Technology
44
(
17
),
6835
6842
.
doi:10.1021/es101509e
.
Li
F.
Behrendt
J.
Wichmann
K.
Otterpohl
R.
2008
Resources and nutrients oriented greywater treatment for non-potable reuses
.
Water Science & Technology
57
(
12
),
1901
1907
.
doi:10.2166/wst.2008.601
.
Li
F.
Wichmann
K.
Otterpohl
R.
2009
Review of the technological approaches for grey water treatment and reuses
.
Science of the Total Environment
407
,
3439
3449
.
doi:10.1016/j.scitotenv.2009.02.004
.
Maimon
A.
Friedler
E.
Gross
A.
2014
Parameters affecting greywater quality and its safety for reuse
.
Science of the Total Environment
487
,
20
25
.
doi:10.1016/j.scitotenv.2014.03.133
.
Mohamed
R. M.
Kassim
A. H.
Anda
M.
Dallas
S.
2013
A monitoring of environmental effects from household greywater reuse for garden irrigation
.
Environmental Monitoring & Assessment
185
(
10
),
8473
8488
.
doi:10.1007/s10661-013-3189-0
.
Mohammed
M.
Donkor
A.
Dubey
B.
2015
Biogas Production Potential of Greywater From Households in Accra Metropolis, Ghana
.
(accessed 13 June 2016)
.
Morel
A.
Diener
S.
2006
Greywater Management in Low and Middle-Income Countries, Review of Different Treatment Systems for Households or Neighbourhoods
.
Swiss Federal Institute of Aquatic Science and Technology (EAWAG)
,
Dübendorf
,
Switzerland
.
Nyarko
K. B.
Oduro-Kwarteng
S.
Dwumfour-Asare
B.
Boakye
K. O.
2016
Incentives for water supply to the urban poor and the role of the regulator in Ghana
.
International Journal of Water
10
(
2/3
),
267
280
.
Oron
G.
Adel
M.
Agmon
V.
Friedler
E.
Halperin
R.
Leshem
E.
Weinberg
D.
2014
Greywater use in Israel and worldwide: standards and prospects
.
Water Research
58
,
92
101
.
doi:10.1016/j.watres.2014.03.032
.
Peloso
M.
Morinville
C.
2014
‘Chasing for Water’: Everyday practices of water access in peri-urban Ashaiman, Ghana
.
Water Alternatives
7
(
1
),
121
139
.
Penn
R.
Schütze
M.
Friedler
E.
2013
Modelling the effects of on-site greywater reuse and low flush toilets on municipal sewer systems
.
Journal of Environmental Management
114
,
72
83
.
doi:10.1016/j.jenvman.2012.10.044
.
Pinto
U.
Maheshwari
B. L.
2010
Reuse of greywater for irrigation around homes in Australia: understanding community views, issues and practices
.
Urban Water Journal
7
(
2
),
141
153
.
doi:10.1080/15730620903447639
.
Rodda
N.
Carden
K.
Armitage
N.
Du Plessis
H. M.
2011
Development of guidance for sustainable irrigation use of greywater in gardens and small-scale agriculture in South Africa
.
Water SA
37
(
5
),
727
738
.
doi:10.4314/wsa.v37i5.10
.
Roesner
L.
Qian
Y.
Criswell
M.
Stromberger
M.
Klein
S.
2006
Long-term Effects of Landscape Irrigation Using Household Graywater – Literature Review and Synthesis
.
WERF Wastewater Treatment & Reuse Final Report
.
Water Environment Research Foundation and the Soap and Detergent Association (SDA)
,
USA
.
Rygaard
M.
Binning
P. J.
Albrechtsen
H. J.
2011
Increasing urban water self-sufficiency: new era, new challenges
.
Journal of Environmental Management
92
(
1
),
185
194
.
doi:10.1016/j.jenvman.2010.09.009
.
Saravanan
V. S.
Mollinga
P. P.
Bogardi
J. J.
2011
Global change, wastewater and health in fast growing economies
.
Current Opinion in Environmental Sustainability
3
,
461
466
.
doi:10.1016/j.cosust.2011.10.009
.
Standard Methods for the Examination of Water and Wastewater
1999
20th edn.
American Public Health Association (APHA), American Water Works Association (AWWA), Water Environment Federation (WEF)
,
Washington, DC
.
Tiruneh
A. T.
2014
A grey water dam design for the treatment and reuse of grey water from single and multiple households
.
Journal of Water Resource and Protection
6
,
1259
1267
.
doi:10.4236/jwarp.2014.614115
.
Trojan Technologies
2010
Trojan UV Factsheet: Endocrine Disruptor Compounds
.
Update on Emerging Contaminants: Endocrine Disruptor Compounds
.
(accessed 24 June 2015)
.
USEPA (US Environmental Protection Agency)
1992
NPDES Storm Water Sampling Guidance Document
.
US Environmental Protection Agency
,
USA
.
WHO
2015
Sanitation Safety Planning: Manual for Safe Use and Disposal of Wastewater, Greywater and Excreta
.
World Health Organization
,
Geneva
,
Switzerland
.
Yu
Z. L. T.
Rahardianto
A.
DeShazo
J. R.
Stenstrom
M. K.
Cohen
Y.
2013
Critical review: regulatory incentives and impediments for onsite graywater reuse in the United States
.
Water Environment Research
85
(
7
),
650
662
.
doi:10.2175/106143013X13698672321580
.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).