Depending on design capacity, agitators consume about 5 to 20% of the total energy consumption of a wastewater treatment plant. Based on inhabitant-specific energy consumption (kWh PE120−1 a−1; PE120 is population equivalent, assuming 120 g chemical oxygen demand per PE per day), power density (W m−3) and volume-specific energy consumption (Wh m−3 d−1) as evaluation indicators, this paper provides a sound contribution to understanding energy consumption and energy optimization potentials of agitators. Basically, there are two ways to optimize agitator operation: the reduction of the power density and the reduction of the daily operating time. Energy saving options range from continuous mixing with low power densities of 1 W m−3 to mixing by means of short, intense energy pulses (impulse aeration, impulse stirring). However, the following correlation applies: the shorter the duration of energy input, the higher the power density on the respective volume-specific energy consumption isoline. Under favourable conditions with respect to tank volume, tank geometry, aeration and agitator position, mixing energy can be reduced to 24 Wh m−3 d−1 and below. Additionally, it could be verified that power density of agitators stands in inverse relation to tank volume.

PD

power density of agitator(s) (W m−3)

td

daily operating time of agitator(s)/mixing system (h d−1)

Wmix,PE

inhabitant-specific energy consumption of agitator(s) (kWh PE1201 a−1)

Wmix,V

volume-specific energy consumption of agitator(s) (Wh m−3d−1)

COD

chemical oxygen demand

MBWWT

mechanical–biological wastewater treatment

PE120

population equivalent; assuming 120g COD PE−1 d−1

SVI

sludge volume index (mL g−1)

TSS

total suspended solids (g L−1)

WWTP

wastewater treatment plant

Energy consumption of wastewater treatment plants (WWTPs) amounts to a small part of the overall national energy requirements. In Germany and the USA the share is estimated to about 1% (Goldstein & Smith 2002; Haberkern et al. 2008). However, WWTPs are the largest energy consumer at the level of municipalities (Haberkern et al. 2008). For this reason and due to increasing energy prices the importance of energy optimization in municipal wastewater treatment has been constantly rising (EPA 2010; Krampe 2013; Marner et al. 2016). In this context, it has also become important to optimize agitator operation in activated sludge tanks (Sharma et al. 2011).

Mixing and aerating in activated sludge tanks are energy-intensive sub-processes within wastewater treatment. When aerating demands about 50–60% of the total energy consumption of a WWTP (Krampe 2011b), in this paper it is shown that mixing consumes about 5–20%. However, in contrast to aeration systems, agitators have not been standing in the central focus of energy optimization yet. Therefore, the aim of this paper is to fill this gap giving a sound overview regarding the actual state and the optimization potential of energy consumption of agitators (generally: mixing systems) in activated sludge tanks.

Data analysis in this paper is based on the evaluation of three different energy indicators: (A) inhabitant-specific energy consumption (kWh PE120−1 a−1, where PE120 is the population equivalent, assuming 120 g chemical oxygen demand (COD) per PE per day), (B) power density (W m−3) and (C) volume-specific energy consumption (Wh m−3 d−1). As only little reference data was available in literature, the first step was to build up a broad and consistent agitator database of operating WWTPs from Austria.

Database

The database for the study was collected by an Excel-sheet based survey throughout all 942 WWTPs >500 PE120 in Austria in the year 2014. Three hundred and ninety-three questionnaires were sent back. Ten per cent of the Excel-sheets had to be excluded because of missing or obviously wrong data. Nine different indicators were built up validating the plausibility of design capacity, average incoming COD load, tank volumes, nominal power and energy consumption of agitators, etc. Only questionnaires that passed the outlier tests of all nine criteria were approved for the study. Finally, the data of 220 treatment plants, ranging from 520 to 950,000 PE120 design capacity, could be used for evaluation. The study covers 30% of all Austrian WWTPs with a design capacity ≥ 2,000 PE120 and 9% of all plants between 500 and 1,999 PE120. However, the 220 evaluated WWTPs are corresponding to a design capacity of about 6 million PE120, which is 28% of the total design capacity of Austria (Table 1). The scope of the database is comparable to Krampe (2011a).

Table 1

Austrian WWTPs ≥ 500 PE120 vs. evaluated WWTPs

Design capacity class (PE120)WWTPs in Austria*
WWTPs evaluated
Number of plants (n)Design capacity (PE120)Number of plants
Design capacity
(n)%(PE120)(%)
500–1,999 309 305,360 28 37,870 12 
≥2,000 633 21,309,060 192 30 5,967,570 28 
TOTAL 942 21,614,420 220 23 6,005,440 28 
Design capacity class (PE120)WWTPs in Austria*
WWTPs evaluated
Number of plants (n)Design capacity (PE120)Number of plants
Design capacity
(n)%(PE120)(%)
500–1,999 309 305,360 28 37,870 12 
≥2,000 633 21,309,060 192 30 5,967,570 28 
TOTAL 942 21,614,420 220 23 6,005,440 28 

The Excel-questionnaire was split into two parts. The first consisted of 13 questions (A–M) regarding the treatment plant as a whole, asking for design capacity, average incoming COD load, total volume of all activated sludge tanks, etc. (see appendix, available with the online version of this paper). The second part consisted of 23 questions (Bx-1 to Bx-23) regarding activated sludge tanks (see appendix). Tanks with the same volume, geometry, aeration type and mixing power were grouped and queried as one tank. So, many small treatment plants filled out the questionnaire for just one tank, whereas bigger plants in most cases filled out for two to four different tanks. Altogether 286 different activated sludge tanks were evaluated, consisting of 228 aerated and 58 unaerated tanks between 52 m³ and 15,000m³ (Table 2).

Table 2

Number of aerated and unaerated tanks evaluated in this paper; sorted by tank volume

Tank volumeNumber aeratedNumber unaeratedTotal number
(m³)(n)(n)(n)
<200 12 20 
200–500 31 23 54 
500–1,000 76 12 88 
1,000–2,000 62 69 
>2,000 51 55 
TOTAL 228 58 286 
Tank volumeNumber aeratedNumber unaeratedTotal number
(m³)(n)(n)(n)
<200 12 20 
200–500 31 23 54 
500–1,000 76 12 88 
1,000–2,000 62 69 
>2,000 51 55 
TOTAL 228 58 286 

Apart from a few impulse mixing systems, the evaluation concentrated on the four following agitator types as categorized in DWA (2013):

  • horizontal drive shaft: fast-running propeller (100–600 rpm, diameter (D) = 0.5–1 m)

  • horizontal drive shaft: slow-running propeller (<100 rpm, D = 1–3 m)

  • vertical drive shaft: hyperboloid-shaped mixer (<100 rpm, D = 1–2 m)

  • vertical drive shaft: slow-running propeller (<100 rpm, D = 1–3m).

Further, detailed investigations of two WWTPs with low mixing energy consumption (WWTP Wartberg/Krems, WWTP Bad Aussee) were carried out. This included the verification of tank volume, agitator power consumption and energy indicators, measurements of near-ground velocity and tank deposits, recording of exact tank geometry and agitator positions, measurements of sludge volume index (SVI) and total suspended solids (TSS), etc. In addition, the low mixing energy data of WWTP Amperverband (Kopmann 2015: impulse aeration/impulse mixing) was evaluated for the study.

Energy indicators

Data evaluation in this paper is based on three different energy indicators.

Indicator (A), inhabitant-specific energy consumption of agitators (Wmix,PE), refers to the incoming COD load to the treatment plant. It is independent of the design capacity of a WWTP. Lindtner (2008) reports values between 1.5 and 4.5 kWh PE120−1 a−1. Wmix,PE is defined as the ratio of annual energy consumption of agitators in activated sludge tanks of a WWTP to the yearly average of the incoming COD load to the plant:
formula
(1)
  • Wmix,PE = kWh PE120−1 a−1 inhabitant-specific energy consumption of agitators

  • Wmix = kWh a−1 annual energy consumption for mixing in activated sludge tanks of a WWTP

  • FCOD = PE120 yearly average of incoming COD load of the WWTP assuming 120 g COD PE−1 d−1

Indicator (B), power density (PD), refers to activated sludge tanks. Baumann et al. (2014) show that PD decreases with increasing tank volume and that target areas of PD range from 4.0 W m−3 at small tank volumes of 200 m³ to 1.5 W m−3 at tank volumes >2,000 m³. It is defined as the quotient of mixing power consumption of agitator(s) and tank volume:
formula
(2)
  • PD = W m−3 power density

  • P = W power consumption of agitator(s)

  • V = m−3 tank volume

Indicator (C), volume-specific energy consumption (Wmix,V), again refers to activated sludge tanks. Based on Wmix,V, the actual energy consumption of agitators can be calculated and compared. Wmix,V is defined as the product of PD and the daily operating time of the agitator (td). It can also be calculated for impulse aeration and impulse mixing systems, multiplying PD and td of the impulse mixing system.
formula
(3)
  • Wmix,V = Wh m−3 d−1 volume-specific energy consumption

  • PD = W m−3 power density

  • td = h d−1 daily operating time of the mixing system

Target value and tolerance value

Due to the large number of specific local process configurations and conditions, it is not reasonable to establish energy benchmarks for mixing only. Nevertheless, as an approximation to benchmarks, so called target values’ and tolerance values’ can be derived from the frequency distributions of the energy indicators. In reference to Haberkern et al. (2008), in this paper they are defined as follows:

  • target value = 25%-quantile

  • tolerance value = median

Influence of tank geometry and aeration

If PD of agitators strongly differs from target values, this may only be due to the agitator (efficiency, dimensioning). Yet in many cases, it is necessary to look more closely at the overall operating and constructional concept of the tank. In this regard, the interaction between tank geometry and PD, mixing and aeration, as well as the optimal positioning of agitators, plays a key role (Frey 2007; Frey 2011a, 2011b; DWA 2013). For example, in oxidation ditches, the geometric shape of the deflection is a crucial factor regarding the necessary energy input (Figure 1). However, depending on the type of mixer, different reactor shapes can be optimal.

Figure 1

Oxidation ditches: influence of tank geometry on mixing power consumption.

Figure 1

Oxidation ditches: influence of tank geometry on mixing power consumption.

Close modal

Near-ground velocity, tank deposits and intermittent operation

Depending on SVI and TSS, near-ground velocity in tanks should vary between 0.10 and 0.25m s−1 (DWA 2013). The prevention of sludge deposits though does not depend on the average value of near-ground velocity but on peak values and their frequency (Frey 2009). Therefore, agitators can be switched off partially or completely during aeration (Haberkern et al. 2008). Also in unaerated phases and tanks intermittent operation of agitators is an energy saving option (Baumann et al. 2014). However, there are some measures to be taken. Most important is the control of nitrate and sludge volume in the outlet of the tank. Further, it has to be ensured that the intermittent operation of agitators is shut down during N-peaks in the feed (Baumann et al. 2014). Other control parameters for the intermittent operation of agitators are the vertical layering of TSS and oxygen concentration (Sharma et al. 2011; Kopmann 2015).

Actual state of energy consumption

Indicator (A), inhabitant-specific energy consumption Wmix,PE, was calculated for all 220 WWTPs. It showed that it is indirectly proportional to the average incoming COD load (expressed as PE120 in Figure 2). So the larger the COD load, the smaller Wmix,PE. In accordance with Lindtner (2008) the target value ranges from 6.8 kWh PE120−1 a−1 (<5,000 PE120) to 1.3 kWh PE120−1 a−1 (>30,000 PE120) (Figure 2).

Figure 2

Inhabitant-specific energy consumption Wmix,PE as a function of average incoming COD load (expressed as PE120; n = 220 WWTPs) – median of Wmix,PE compared to median of inhabitant-specific energy consumption of MBWWT; median of MBWWT according to ÖWAV (2013).

Figure 2

Inhabitant-specific energy consumption Wmix,PE as a function of average incoming COD load (expressed as PE120; n = 220 WWTPs) – median of Wmix,PE compared to median of inhabitant-specific energy consumption of MBWWT; median of MBWWT according to ÖWAV (2013).

Close modal

Further, the share of mixing energy within the total energy consumption was of interest. Therefore, the medians of Wmix,PE are compared to the medians of inhabitant-specific energy consumption of mechanical–biological wastewater treatment (MBWWT). MBWWT, a benchmarking term introduced by Lindtner et al. (2004), includes mixing, aeration, return sludge pumping, primary sedimentation tanks and final clarifiers (ÖWAV 2013). It is by far the most energy-intensive sub-process within wastewater treatment (Lindtner 2008; Haslinger et al. 2016). Comparing the medians, it can be shown that mixing demands a share of about 10 to 25% of MBWWT (Figure 2). Now taking into account that aeration consumes about 50–60% of the total energy consumption of a WWTP (Krampe 2011b), but about 70% of MBWWT (Lindtner 2008), it can be calculated that mixing demands a share of about 5 to 20% of the total energy consumption of a WWTP.

Finally, it can be shown that the share of mixing energy increases with decreasing COD loads. So, bigger treatment plants – with influent loads ≥35,000 PE120 – need a share of about 10% of MBWWT, whereas smaller treatment plants – with influent loads up to 5,000 PE120 – need about 25% of MBWWT (Figure 2); again corresponding to about 5–20% of the total energy consumption of a WWTP.

Indicator (B), power density PD, was calculated for all 286 tanks. Both PD and its target values and medians prove to be indirectly proportional to tank volume. Target values range from 5.7 W/m³ (≤200 m³) to 1.1 W/m³ (>2,000 m³), medians from 6.8 W/m³ (≤200 m³) to 1.6 W/m³ (>2,000 m³). Target values are within, and medians tend to be at, the upper limit of the target areas indicated by Baumann et al. (2014) (Figure 3).

Figure 3

Power density PD of aerated and unaerated tanks as a function of tank volume; n = 286 tanks.

Figure 3

Power density PD of aerated and unaerated tanks as a function of tank volume; n = 286 tanks.

Close modal

The influence of agitator type (fast-running propeller; slow-running propeller; hyperboloid-shaped mixer) on PD was examined. Fast-running propellers are only used for tank volumes <1,000 m³ and are operated with higher PD than other agitator types. The target value for fast-running propellers was assessed to 5.2 W m−3. Between slow-running propellers (horizontal or vertical drive shaft) and hyperboloid-shaped mixers, no difference regarding PD could be found. PD target values for tanks <1,000 m³ range around 2.4 W m−3 each.

Tank deposits are an important control parameter regarding low mixing power densities. Data evaluation showed that PD below the target values does not lead to more deposits than PD above the target values (Table 3). This proves that the PD target values elaborated in this paper can be put into praxis without harming sludge suspension.

Table 3

Percentage of no/little/a lot tank deposits (as observed by operators): PD <target value compared to PD > target value; calculated with target values according to Figure 3 

Tank depositsPD < target valuePD > target value
(n = 58 tanks)(n = 166 tanks)
No 28% 25% 
Little 66% 68% 
A lot 7% 7% 
TOTAL 100% 100% 
Tank depositsPD < target valuePD > target value
(n = 58 tanks)(n = 166 tanks)
No 28% 25% 
Little 66% 68% 
A lot 7% 7% 
TOTAL 100% 100% 

Indicator (C), volume-specific energy consumption Wmix,V, has more than one main influencing parameter. Therefore, it cannot be evaluated like PD and Wmix,PE. Wmix,V is mainly dependent on PD and td. Due to the influence of PD, there is also a slight dependency on tank volume (Figure 4). However, of bigger importance is the aeration. On average, Wmix,V in aerated tanks is twice as low as in unaerated tanks. In aerated tanks the average Wmix,V is about 50 Wh m−3 d−1 (Figure 4(a)), in unaerated tanks about 100 Wh m−3 d−1 (Figure 4(b)). This is mainly due to the mixing energy contribution of aeration. Consequently, td in most aerated tanks can be lower than in unaerated tanks, as there is energy input from aeration (see Table 5). In aerated tanks the spectrum of Wmix,V ranges from 14 to 119 Wh m−3 d−1 (Figure 4(a)), in unaerated tanks from 43 to 242 Wh m−3 d−1 (Figure 4(b)).

Figure 4

Volume-specific energy consumption Wmix,V as a function of tank volume: (a) aerated (n = 228) and (b) unaerated tanks (n = 58). N/DN: nitrification/denitrification.

Figure 4

Volume-specific energy consumption Wmix,V as a function of tank volume: (a) aerated (n = 228) and (b) unaerated tanks (n = 58). N/DN: nitrification/denitrification.

Close modal

On-site validation of low mixing energy

Activated sludge tanks >2,000 m³ have a PD target value of about 1 W m−3 (Figure 3). At continuously mixed tanks (→td = 24 h d−1) this corresponds to a low Wmix,V of 24 Wh m−3 d−1. For the continuously mixed oxidation ditches at the WWTP Wartberg/Krems (Figure 4(a)) this could be confirmed by on-site measurements. Although a low Wmix,V of 22 Wh m−3 d−1, near-ground velocities proved to be sufficiently high. The average values of nine different measurement points inside the oxidation ditch came to be 0.13–0.23 m s−1; the maximum values came to be 0.16–0.30 m s−1. In accordance with that, no significant deposits could be detected on the base of the tanks. An important reason for the good mixing performance of the oxidation ditches at WWTP Wartberg/Krems is to be found in the favourable agitator position and deflection geometry that equals the optimal geometry in Figure 1.

The oxidation ditches of WWTP Wartberg/Krems show that for aerated tanks a low Wmix,V of about 24 Wh m−3 d−1 is feasible in practice under favourable conditions with respect to tank volume, tank geometry and agitator position. However, especially examples of impulse aeration show that Wmix,V in aerated tanks can be reduced to even below 24 Wh m−3 d−1. This could be confirmed by on-site measurements at the rectangular 1,000 m³ impulse aeration tanks at the WWTP Bad Aussee (Wmix,V = 6 Wh m−3 d−1) (Figure 4(a)). Again, no significant tank deposits could be detected.

As Wmix,V of unaerated tanks on average is twice as high as for aerated tanks, for unaerated tanks, an optimization goal of about 48 Wh m³ d−1 can be approximated. This is also indicated by similar frequency distributions: 18% of aerated tanks fall below 24 Wh m−3 d−1, 17% of unaerated tanks fall below 48 Wh m−3 d−1. So both values are in the range of the 25%-quantile (defined as target value).

Energy optimization

The optimization of energy consumption of agitators in activated sludge tanks can be divided into two subareas that can be analyzed separately over a wide range: (1) the reduction of PD and (2) the reduction of td. In the best case, both PD and td are optimized. However, the reduction of PD, td or both PD and td in all cases leads to a reduction of the Wmix,V and hence to mixing energy optimization.

The reduction of PD

Depending on whether the tolerance value (median) or the target value (25%-quantile) is recognized as an optimization goal, it can be assumed that approximately 50 to 75% of the tanks have an energetic optimization potential regarding PD. Based on this consideration an estimation of the energy saving potential in regard to PD was carried out for Austrian WWTPs. The 220 WWTPs of the study were taken into account. If PD in all 286 tanks is reduced to target value about 40% of mixing energy in activated sludge tanks could be saved. With reduction of PD to tolerance value, about 25% of mixing energy could be saved (Table 4).

Table 4

Energy saving potential by reducing power density to tolerance value or target value – data basis: 220 WWTPs corresponding to 286 tanks with an overall design capacity of ∼6 million PE120 and an overall volume of ∼830,000 m³

Tank volumeNumber of tanksEnergy consumptionEnergy saving potential by reduction to tolerance value
Energy saving potential by reduction to target value
(m³)(n)(kWh a−1)(kWh a−1)(%)(kWh a−1)(%)
≤200 20 302,433 104,892 35 147,354 49 
200–500 54 902,823 243,509 27 385,893 43 
500–1,000 88 3,205,669 895,217 28 1,405,026 44 
1,000–2,000 69 3,415,906 739,676 22 1,193,757 35 
>2,000 55 5,328,494 1,117,941 21 2,110,003 40 
TOTAL 286 13,155,325 3,101,234 24 5,242,033 40 
Tank volumeNumber of tanksEnergy consumptionEnergy saving potential by reduction to tolerance value
Energy saving potential by reduction to target value
(m³)(n)(kWh a−1)(kWh a−1)(%)(kWh a−1)(%)
≤200 20 302,433 104,892 35 147,354 49 
200–500 54 902,823 243,509 27 385,893 43 
500–1,000 88 3,205,669 895,217 28 1,405,026 44 
1,000–2,000 69 3,415,906 739,676 22 1,193,757 35 
>2,000 55 5,328,494 1,117,941 21 2,110,003 40 
TOTAL 286 13,155,325 3,101,234 24 5,242,033 40 

The reduction of td

The reduction of td (→ intermittent operation of agitators) is an energy saving option already being implemented in many pressure-aerated tanks. However, there are differences between different tank types. In oxidation ditches, the share of agitators being operated intermittently is 26%, in circular tanks it is 37%, in rectangular tanks 67%. This can be explained with different operating requirements; e.g. in oxidation ditches, propellers are needed to induce the direction of the water flow during aeration phases, in rectangular tanks not. Anyway, 33% continuously operated agitators also show an optimization potential at rectangular tanks (Table 5).

Table 5

Relative number of agitators with different td (24 h, 14–22 h, 2–12 h) depending on aeration type (pressure aeration, unaerated tanks) and tank type (oxidation ditch, circular tanks, rectangular tanks)

Daily operating time tdOxidation ditchCircular tanksRectangular tanks
(h d−1)(%)(%)(%)
Pressure aeration 
 24 74 63 33 
 14–22 14 17 34 
 2–12 12 20 33 
Unaerated tanks 
 24 86 86 82 
 <24 14 14 18 
Daily operating time tdOxidation ditchCircular tanksRectangular tanks
(h d−1)(%)(%)(%)
Pressure aeration 
 24 74 63 33 
 14–22 14 17 34 
 2–12 12 20 33 
Unaerated tanks 
 24 86 86 82 
 <24 14 14 18 

For unaerated tanks, there is no significant difference between tank types. In the case of oxidation ditches, circular tanks and rectangular tanks, approximately 85% of the agitators are being operated continuously. Nevertheless, about 15% of the tanks show that the continuous operation of agitators is no operating necessity (Table 5). This is consistent with references in DWA (2013) and Baumann et al. (2014).

Energy saving options

It turns out that the range of energy saving options for tank mixing is located between two opposite poles (Figure 5). At one end of the spectrum there are tanks continuously mixed with low PD (WWTP Wartberg/Krems: PD = 0.92 W m−3). At the other end of the spectrum there are tanks mixed with short high pulses of energy. These energy pulses may either be introduced by air (WWTP Bad Aussee: PD = 25 W m−3; WWTP Amperverband: PD = 15 W m−3) or by mixing (WWTP Amperverband: PD = 4.5 W m−3). The choice of the energy saving option largely depends on the specific operating conditions of the tank. As a consequence, intermittent operation of agitators with PD < 1 W m−3 is not likely to be reasonable. On the other hand, impulse aerating and impulse mixing can be regarded as ‘extreme variants’ of intermittent mixing.

Figure 5

Volume-specific energy consumption isoline – exemplified with Wmix,V = 24 Wh m−3 d−1; data from Amperverband according to Kopmann (2015). N/DN: nitrification/denitrification.

Figure 5

Volume-specific energy consumption isoline – exemplified with Wmix,V = 24 Wh m−3 d−1; data from Amperverband according to Kopmann (2015). N/DN: nitrification/denitrification.

Close modal
In Figure 5 the general relationship between PD and td is demonstrated for a low Wmix,V of 24 Wh m−3 d−1: the shorter the duration of energy input td, the higher power density PD on the respective volume-specific energy consumption isoline. The relationship between Wmix,V, PD and td always follows a power function with the negative exponent n = −1 (Equation (4)). Along the respective volume-specific energy consumption isoline, the same mixing energy (Wmix,V) is consumed. Consequently, different mixing concepts (high PD, low td; low PD, high td) can easily be compared with each other underlying a volume-specific energy consumption isoline.
formula
(4)

Agitators consume 5 to 20% of the total energy consumption of a WWTP. Up to 75% of the evaluated tanks have an optimization potential regarding energy consumption. This shows that mixing is an important issue in the energy optimization of WWTPs. The energy consumption indicators applied in this paper (Wmix,PE, PD, Wmix,V) proved to be well applicable to both the calculation of the actual state and of the optimization potential of mixing energy. The first step for operators regarding optimization is thus to compare these indicators with the target values compiled in this paper.

The optimization itself can be split into two mostly independent strategies: the reduction of power density PD and the reduction of daily operating time td. Ideally, both are optimized. However, this approach is limited by the volume-specific energy consumption Wmix,V. The following principle applies: the smaller td, the higher PD on the respective volume-specific energy consumption isoline. Along this isoline, the range of energy saving options varies from continuous mixing with power densities as small as 1 W m−3 to mixing by short, intense energy impulses (impulse aeration, impulse mixing). When tank geometry, tank volume, agitator position and aeration are favourable, volume-specific mixing energy can be reduced to 24 Wh m−3 d−1 based on available full-scale experiences, and even below.

Aeration shows a major influence on mixing energy consumption Wmix,V. Concerning the complex interdependencies between the energy consumption of mixing and aeration, further research, based on large-scale experiments and/or CFD simulations, is needed.

Baumann
,
P.
,
Maurer
,
P.
&
Roth
,
M.
2014
Senkung des Stromverbrauchs auf Kläranlagen. Leitfaden für das Betriebspersonal (Reduction of the Energy Consumption of WWTPs – Manual for Operators)
.
Heft 4, 3. Aufl.
,
DWA Landesverband Baden-Württemberg
,
Stuttgart, Germany
.
BMLFUW
2016
Kommunales Abwasser – Österreichischer Bericht 2016 (Municipal Wastewater - Austrian Report 2016)
.
Bundesministerium für Land- und Forstwirtschaft, Umwelt und Wasserwirtschaft
,
Vienna, Austria
.
DWA
2013
Merkblatt DWA-M 229-1. Systeme zur Belüftung und Durchmischung von Belebungsanlagen – Teil 1: Planung, Ausschreibung und Ausführung (Leaflet DWA-M 229-1. Systems for Aeration and Mixing of Activated Sludge Plants – Part 1: Planning, Tendering and Execution). Deutsche Vereinigung für Wasserwirtschaft, Abwasser und Abfall e.V
.
EPA
2010
Evaluation of Energy Conservation Measures for Wastewater Treatment Facilities
.
US Environmental Protection Agency Office of Wastewater Management
,
September 2010
.
Frey
,
W.
2007
The role of diffuser arrangement and mixing for efficiency optimization of fine bubble aeration systems
. In:
Large Waste Water Treatment Plant Conference, Vienna, September 2007
.
Frey
,
W.
2009
Garantienachweise für die maschinelle Ausrüstung von Kläranlagen – Belüftungssysteme und Rührwerke (Guaranty Values for Mechanical Equipment of WWTPs – Aeration Systems and Agitators). Schriftenreihe Kläranlagennachbarschaften, Band 17
.
Frey
,
W.
2011a
Messwerte und Kennzahlen der maschinellen Ausrüstung auf Kläranlagen (Mechanical Equipment of WWTPs: Measured Values and Key Figures). Wiener Mitteilungen, Band 224, S. 253-268, 2011
.
Frey
,
W.
2011b
Energieeffizientes Mischen und Belüften von Belebungsbecken (Energy-efficient mixing and aerating of activated sludge tanks)
.
25. Kalsruher Flockungstage, KIT Karlsruhe, 14–15 November 2011
.
Goldstein
,
R.
&
Smith
,
W.
2002
Water & Sustainability (Volume 4): US Electricity Consumption for Water Supply & Treatment – The Next Half Century
.
Electric Power Research Institute (EPRI)
,
Palo Alto, CA, USA
.
Haberkern
,
B.
,
Maier
,
W.
&
Schneider
,
U.
2008
Steigerung der Energieeffizienz auf Kommunalen Kläranlagen (Increasing the Energy Efficiency of Municipal WWTPs)
.
Umweltbundesamt
,
Dessau-Roßlau, Germany
.
Kopmann
,
T.
2015
Mischen mit Luft (Impulse aeration). Seminarband “Belüftung auf Abwasserreinigungsanlagen”, Vienna, 19 May 2015
.
Krampe
,
J.
2011a
Assessment of diffuser pressure loss on WWTPs in Baden-Württemberg
.
Water Science and Technology
63
(
12
),
3027
3033
.
Krampe
,
J.
2013
Energy benchmarking of South Australian WWTPs
.
Water Science and Technology
67
(
9
),
2059
2066
.
Lindtner
,
S.
2008
Leitfaden für die Erstellung eines Energiekonzeptes kommunaler Kläranlagen (Guidelines for the Development of an Energy Concept for Municipal WWTPs). Ingenieurbüro k2 W
.
Lindtner
,
S.
,
Kroiss
,
H.
&
Nowak
,
O.
2004
Benchmarking of municipal wastewater treatment plants (an Austrian project)
.
Water Science and Technology
50
(
7
),
265
271
.
Marner
,
S. T.
,
Schröter
,
D.
&
Jardin
,
N.
2016
Towards energy neutrality by optimising the activated sludge process of the WWTP Bochum-Ölbachtal
.
Water Science and Technology
73
(
12
)
3057
3063
.
ÖWAV
2013
Benchmarking für Kläranlagen – Geschäftsjahr 2013. (Benchmarking for WWTP – 2013). Österreichischer Wasser- und Abfallwirtschaftsverband, 2013
.
ÖWAV
2015
Branchenbild der österreichischen Abwasserwirtschaft 2016 (Profile of Austrian Wastewater Management 2016). Österreichischer Wasser- und Abfallwirtschaftsverband
.

Supplementary data