In this study, the performance of the electrochemical peroxidation (ECP) process for removing the volatile suspended solids (VSS) content of waste-activated sludge was evaluated. The Fe2+ ions required by the process were obtained directly from iron electrodes in the system. The performance of the ECP process was investigated in various operational conditions employing a laboratory-scale pilot setup and optimized by response surface methodology (RSM). According to the results, the ECP process showed its best performance when the pH value, current density, H2O2 concentration and the retention time were 3, 3.2 mA/cm2, 1,535 mg/L and 240 min, respectively. In these conditions, the introduced Fe2+ concentration was approximately 500 (mg/L) and the VSS removal efficiency about 74%. Moreover, the results of the microbial characteristics of the raw and the stabilized sludge demonstrated that the ECP process is able to remove close to 99.9% of the coliforms in the raw sludge during the stabilization process. The energy consumption evaluation showed that the required energy of the ECP reactor (about 1.8–2.5 kWh (kg VSS removed)−1) is considerably lower than for aerobic digestion, the conventional waste-activated sludge stabilization method (about 2–3 kWh (kg VSS removed)−1). The RSM optimization process showed that the best operational conditions of the ECP process comply with the experimental results, and the actual and the predicted results are in good conformity with each other. This feature makes it possible to predict the introduced Fe2+ concentrations into the system and the VSS removal efficiency of the process precisely.

Sludge management, especially waste-activated sludge stabilization, is a fundamental area of concern in conventional wastewater treatment plants. Waste-activated sludge, which is considered to be a clear potential threat for the environment, is the major by-product of the wastewater treatment process (Bernal-Martínez et al. 2010; Ghatak 2014). There is therefore a demand for novel treatment technologies that are capable of achieving significant removal efficiencies with more convenient operational conditions. Recently, the electrochemical advanced oxidation processes (EAOPs) have been considered for wastewater treatment (Babuponnusami & Muthukumar 2014). The efficiency of advanced oxidation processes (AOPs) in the degradation of biological organic compounds, and toxic and chemically resistant substances, has made these processes superior to research or use (Oturan & Aaron 2014; Wang et al. 2016). Traditionally, it is considered that AOPs include a large variety of degradation processes in which very oxidizing and unstable species have the predominant role. Among these radicals, the hydroxyl radical is considered the most important free radical in chemistry and biology due to its multiple implications and applications (Brillas et al. 2009). This radical is one of the most impressive oxidizing agents (E0 = 2.87) and reacts non-selectively to remove the afore-mentioned materials (Brillas et al. 2009; Vilhunen & Sillanpää 2010; Lamsal et al. 2011; Chaplin 2014; Oturan & Aaron 2014; Sirés et al. 2014; Pérez et al. 2016). The Fenton process is one of the most frequently used AOPs, and has advantages such as low initial cost, easy operation and the production of non-toxic by-products (Neyens & Baeyens 2003; Canizares et al. 2009). In the Fenton reactions, the ferrous ions are added as salts (typically FeCl2 or FeSO4), which increases the concentration of chloride or sulphate ions in the wastewater, creating a secondary contamination. Combining the Fenton process and electrochemical methods has resulted in various process such as the electrochemical peroxidation (ECP) process, which is more efficient than the Fenton processes, without their disadvantages (Brillas et al. 2009; Oturan & Aaron 2014; Sirés et al. 2014). ECP is a combination of electrocoagulation and the classic Fenton process, and is able to reduce organics by degradation, coagulation, and flotation of pollutants in wastewaters (Pekey 2016). In the ECP process, H2O2 is added externally as in conventional Fenton processes, but Fe2+ ions are provided by anodic dissolution of sacrificial iron anodes in an undivided electrolytic cell. During the ECP process, the generated hydroxyl radicals oxidize the pollutants in wastewater. The related reactions are represented by Equations (1) and (2) (Brillas et al. 2009; Akyol et al. 2013; Sirés et al. 2014).
formula
(1)
formula
(2)
Several studies carried out on the ECP process have focused on water treatment. Due to the ability of the ECP process to remove various contaminants, it could be also appropriate for waste-activated sludge stabilization (Chiarenzelli et al. 2001; Gutiérrez et al. 2010; Kokkali 2011; Liu et al. 2012; Ozyonar & Karagozoglu 2015). However, there is a lack of assessment of iron electrode functionality, as one of the most influential contributing factors in the ECP process.

With this in mind, we investigated the effectiveness of this technology for waste-activated sludge stabilization at a laboratory scale. The main objective of the present study was to consider the effects of various operational parameters on introduced Fe2+ concentrations and volatile suspended solids (VSS) removal efficiency as the important factors of the ECP process.

Due to the remarkable dependency of the ECP process on pH, H2O2 concentration, current density and retention time (Umar et al. 2010; Nidheesh & Gandhimathi 2012; Sirés et al. 2014), these factors were considered as input variables, and the introduced iron ions (Fe2+) and the VSS removal efficiency as responses. In order to optimize the performance of the ECP process in this study, response surface methodology (RSM) was used to develop a mathematical correlation between the operational parameters of the ECP process and its responses. This methodology is a successfully applied statistics-based method for designing experiments, evaluating the individual and interaction effects of independent variables, and optimizing the process parameters with a limited number of experiments (Ghafari et al. 2009; Zhu et al. 2011; Rasouli Sadabad & Gholikandi 2017). In addition, given the significance of the electrical energy consumption of the ECP reactor and the microbial characteristics of stabilized sludge, these two factors were also investigated in the optimum operating conditions.

Materials

The pilot studies were conducted at the laboratory scale (Figure 1). The waste-activated sludge studied was obtained from Shahid Mahalati urban sewage treatment plant which is located in northeastern Tehran, Iran. The characteristics of this waste-activated sludge are presented in Table 1.

Table 1

Excess sludge specification

PropertyValue
pH 6.53–7.31 
Temperature(0C) 13.5–15.7 
COD (mg/L) 5,768–10,985 
VSS (mg/L) 3,136–6,682 (2.6–5.6 (g/kg)) 
VS (mg/L) 3,201–6,810 (2.7–5.8 (g/kg)) 
TS (mg/L) 4,375–8,825 (3.8–7.6 (g/kg)) 
TSS (mg/L) 4,085–8,537 (3.5–7.4 (g/kg)) 
VSS/TSS 0.76–0.78 
PropertyValue
pH 6.53–7.31 
Temperature(0C) 13.5–15.7 
COD (mg/L) 5,768–10,985 
VSS (mg/L) 3,136–6,682 (2.6–5.6 (g/kg)) 
VS (mg/L) 3,201–6,810 (2.7–5.8 (g/kg)) 
TS (mg/L) 4,375–8,825 (3.8–7.6 (g/kg)) 
TSS (mg/L) 4,085–8,537 (3.5–7.4 (g/kg)) 
VSS/TSS 0.76–0.78 

COD = chemical oxygen demand; VS = volatile solids; TS = total dry solids; TSS = total suspended solids.

Figure 1

Photograph and schematic diagram of experimental setup.

Figure 1

Photograph and schematic diagram of experimental setup.

Close modal

As shown in Figure 1, the reactor was made up of a one litre Plexiglas cylinder, containing 0.9 litres of the waste-activated sludge sample, fitted with four iron electrodes (purity >99.5%). The electrode dimensions were 140 mm × 60 mm × 1 mm, and were made from iron in order to supply the Fe2+ required as a catalyst for to the reaction shown in Equation (2). In order to study the rate of the introduced Fe2+ to the system via the electrodes, an inductively coupled plasma spectrometer (ICP; 7500; P/N 211-46500 -92) measuring apparatus was used to measure the introduced Fe2+ concentration. The insertion depth (inside the sludge) and the aspect ratio of each electrode with sludge were about 100 mm and 100 mm × 60 mm, respectively. Also, the distance between the electrodes was 1.5 cm (Nidheesh & Gandhimathi 2012). An electric motor (Zheng, zs-ri, 6(V) DC, 366 rpm) was used to provide proper mixing in the system. To set the current and voltage consumption of the system, a digital power supply (DAZHENG, DC Power, ps-305d, 0–5 A, 0–30 V) was used and polarity reversal was used for changing the polarity of the electrodes.

All the chemicals used in this study were obtained from Merck group, Germany. Sodium hydroxide (50% purity, 0.1 N) and sulphuric acid (98% purity, 0.1 N) were used in the experiments for pH adjustment. The lauryl tryptose broth (LTB), brilliant green bile (BGB), Escherichia coli (EC) and plate count agar (PCA) cultures were used to study and measure the pre- and post-experiment values of the following sludge microbial characteristics: coliform, total coliform, heat-resistant coliforms, and heterotroph bacteria.

Sampling and test methods

First, the rate of Fe2+ introduced into the system was studied in order to obtain a thorough understanding of the electrodes' performance under different operational conditions and the effect of operational parameters on the electrodes. Current density (mA/cm2), retention time (min), pH and H2O2 concentration (mg/L) were considered as the operational parameters and introduced Fe2+ concentrations and the VSS removal efficiencies as the responses of the ECP process. The current polarity was reversed every 3 min in order to avoid passivation and to reach equal dissolution of both electrodes. During this stage, hydrogen peroxide was injected into the system and the sludge sample pH was adjusted by adding sulphuric acid or NaOH. Upon connection to the power supply, the electrodes were placed into the system and the voltage consumption was measured after adjusting the current to the desired level. After the test, sampling was performed at a sludge depth of 100 mm and the concentration of the Fe2+ determined using the ICP apparatus. Upon completion of the test, the VSS removal efficiency, final voltage and microbial characteristics of the outlet sludge were measured. All the tests were conducted in conformity with the standard method (APHA, AWWA & WEF 2012). Each group of tests was repeated three times.

Experimental design and data analysis

The results of the experiments were optimized by Design-Expert® software (Stat-Ease Inc., Minneapolis, USA) using central composite design (CCD) analysis. The experiments were designed through the software and carried out in the conditions determined. Then the results of the experiments were inserted to the model in order to identify the coefficients and effects of each parameter.

Effect of independent parameters on the introduced Fe2+ and the VSS removal efficiency

Iron is recognized as the best catalyst for the Fenton-based processes (Sirés et al. 2014). Controlling the amount of Fe2+ obtained from iron electrodes in the ECP process would not only limit and/or inhibit negative effects on the reaction, represented by Equation (3), and the available Fe2+ concentration in the system, but also increase the efficiency of the studied system (Abdessalem et al. 2008; Brillas et al. 2009).
formula
(3)

Due to the important role of the Fe2+ introduced into the system from the electrodes on the effectiveness of the ECP process, we first studied the effect of each individual parameter on this response, and then the effect of the mentioned parameters and introduced Fe2+ on the extent of the VSS removal efficiency.

pH

The catalytic performance of the introduced Fe2+ concentration strongly is dependent on the pH value of the solution (Duesterberg et al. 2008). In order to evaluate the effect of pH, the other operational parameters were kept approximately constant (H2O2 = 1,695 mg/L, current density = 2.8 mA/cm2, retention time = 120 min), and the experiments were carried out at various pH values. Figure 2 shows the experimental results of the introduced Fe2+ and the VSS removal efficiency in the different operating conditions. Also, Figure 2(a) shows the VSS removal efficiencies and the introduced Fe2+ concentrations in different pH values of the process. According to Figure 2(a), the introduced Fe2+ concentration in the system from the electrodes was dependent on pH values as well as the VSS removal efficiency. The introduced Fe2+ concentration did not show significant change at pH values lower than 5, but increasing the pH value to 6 led to a sudden reduction. Further increasing the pH to values greater than 6 showed an increasing trend with a slight slope, which is negligible. Also, according to Figure 2(a), the maximum VSS removal efficiency was 67% at pH = 3. Moreover, for pH values lower than 2 and higher than 5, the VSS removal efficiency decreased considerably. Based on these results and observations, it seems that at pH values higher than 5, the Fe3+ species would be deposited in the form of Fe(OH)3, which leads to the reduction of the formation and introduction of hydroxyl radicals into the system as well as the spontaneous decomposition of hydrogen peroxide (Shemer & Linden 2006). At pH values lower than 2, Fe-containing complexes such as [Fe(H2O)6]2+ which react much more slowly with hydrogen peroxide than other species are able to be formed (Wang et al. 2010). Moreover, in the presence of high H+ concentrations, hydrogen peroxide would decompose and be converted into the stable species ([H3O2]+) which reacts with Fe2+ slower than hydrogen peroxide (Zhou et al. 2007; Ghoneim et al. 2011).

Figure 2

Experimental results of the introduced Fe2+ and the VSS removal efficiency in different operating conditions.

Figure 2

Experimental results of the introduced Fe2+ and the VSS removal efficiency in different operating conditions.

Close modal

Current density

The current density is an important functional parameter in the Fenton-based reaction processes since it affects subsequent H2O2 production, Fe2+ reduction and OH0 production (Zhang et al. 2007; Sirés et al. 2014). In order to evaluate the effect of the current density, the other operational parameters were kept approximately constant (H2O2 = 1,695 mg/L, pH = 3, retention time = 120 min), and the experiments were carried out at various current densities. Figure 2(b) shows the introduced Fe2+ concentrations and the VSS removal efficiencies at various current densities. As shown in Figure 2(b), in the absence of current, no Fe2+ is produced from the electrodes and the VSS removal reactions do not happen. Increasing the current density leads to an almost linear increase in the introduced Fe2+ concentration. Therefore, the behaviour of iron electrodes can clearly be observed at the different current densities. Based on the results, increasing the current density increases the efficiency of the system, particularly OH0 generation (Sirés et al. 2014).

According to Figure 2(b), the maximum VSS removal efficiency of the process (70%) was obtained at the current density of 3.2 mA/cm2. Further increasing the current density (from 3.2 to 4.17 mA/cm2) led to reducing the VSS removal efficiency to 64%. Thus, an increase in current density further increased undesired reactions and reduced the VSS removal efficiency of the system (Brillas et al. 2009; Sirés et al. 2014).

H2O2 concentration and [H2O2]/[Fe2+] ratio

In order to evaluate the effect of H2O2 concentration and [H2O2]/[Fe2+] ratio, the other operational parameters were kept approximately constant (pH = 3, current density = 3.2 mA/cm2, retention time = 120 min), and the experiments were carried out at various H2O2 concentrations and [H2O2]/[Fe2+] ratios. Figure 2(c) and 2(e) represent the results of evaluating these parameters. As shown in Figure 2(c) the presence or absence of hydrogen peroxide has no significant effect on the introduced Fe2+ concentration, but change the VSS removal efficiency remarkably. In the absence of H2O2, the VSS removal efficiency of the process was zero. The VSS removal efficiency shows an upward trend by increasing the H2O2 concentration to 1,535 mg/L (the ratio [H2O2]/[Fe2+] = 6.28, shown in Figure 2(e)), but at higher concentrations, this upward trend reverses. The maximum VSS removal efficiency for the sludge was obtained as 71% in these conditions. In other words, the system efficiency decreased as a result of Equation (4) which occurred within the 6.28 < [H2O2]/[Fe2+] < 7.92 range. It seems that at higher concentrations of H2O2, the system efficiency decreased by consumption of hydroxyl radicals in reaction, represented by Equation (4), and the subsequent reduction in the concentration of hydroxyl oxidizing agents (Muruganandham & Swaminathan 2004).
formula
(4)

Retention time

Because of the long retention time demanded by most conventional sludge stabilization methods (aerobic/anaerobic digestion), one of their significant disadvantages, the much shorter retention time of EAOPs is considered to be a noticeable advantage (Huang et al. 2001; Gholikandi et al. 2014; Oturan & Aaron 2014). Accordingly, the required retention time in the ECP process for stabilization of the waste-activated sludge was considered one of the operational parameters in the current study. In order to evaluate the retention time, the values of the other operational parameters were kept approximately constant (pH = 3, current density = 3.2 mA/cm2, H2O2 = 1,535 mg/L), and the experiments were carried out using various retention times. Figure 2(d) shows the introduced Fe2+ concentrations and the VSS removal efficiencies in various retention times. As shown in Figure 2(d), increasing the retention time increases (approximately linearly) the introduced Fe2+ concentration into the system, until it reached 780 mg/L, in 6 hours. Also, in 2 and 4 hours after the start of the test, the sludge VSS removal efficiency had reached 71% and 74%, respectively. Because the efficiency exhibited no significant change after 4 hours of the test, it was concluded that the optimum retention time and the maximum VSS removal efficiency in the ECP system were 4 hours and 74%, respectively.

Altering the microbial characteristics of the waste-activated sludge

The results obtained from evaluating the microbial characteristics of the raw and stabilized sludge by the ECP process in the laboratory demonstrated that this system had a highly acceptable performance (99.9% efficiency) in altering the microbial characteristics of the sludge. Table 2 shows the microbial characteristics of raw and stabilized waste-activated sludge. Considering the high degree of coliform removal, the stabilized waste-activated sludge was placed in Class A of the US EPA standard. The status of the microbial characteristics makes this sludge able to be reused, particularly in agriculture.

Table 2

Raw and stabilized sludge microbial characteristics

 Coliforms
MPN/100 ml
Total coliforms
MPN/100 ml
Fecal coliform
MPN/100 ml
(HPC)
CFU/0.1 ml
Raw sludge 8,000,000 6,000,000 1,600,000 1,780,000 
Stabilized sludge 730 530 250 320 
Growth medium LTB BGB EC PCA 
Removal efficiency (%) 99.9 99.9 99.9 99.9 
 Coliforms
MPN/100 ml
Total coliforms
MPN/100 ml
Fecal coliform
MPN/100 ml
(HPC)
CFU/0.1 ml
Raw sludge 8,000,000 6,000,000 1,600,000 1,780,000 
Stabilized sludge 730 530 250 320 
Growth medium LTB BGB EC PCA 
Removal efficiency (%) 99.9 99.9 99.9 99.9 

Electrical energy consumption

The electrical energy consumption of the system was calculated based on the voltage consumption data obtained from the supply source connected to the electrodes at the optimum operational conditions of the laboratory-scale setup. In order to reduce possible errors, the experiments were repeated three times and the electricity consumption was calculated. Electricity consumption of the system during the experiment was calculated using Equation (5) (Ghosh et al. 2011).
formula
(5)
where UED (kWh per kg of the removed VSS) is considered as the required electrical energy, V as the consumed voltage (V), I as the applied current (A), t as the test retention time (h), v as the system volume (L), VSSin as the inlet sludge rate (mg/L), and η as the VSS removal efficiency (expressed as a percentage) of the system.

Thus, the energy consumption was obtained as 1.8–2.5 kWh per kg of removed VSS. In contrast, based on the available resources, the VSS removal in the conventional bio-aerobic method used for stabilization of the waste-activated sludge (Wang et al. 2008) is reported between 35% and 50% with the corresponding energy consumption of 2–3 kWh per kg of VSS removal (Tchobanoglous 1979). Therefore, as compared with aerobic digestion, as a conventional system, the ECP reactor provided approximately twice the efficiency, and less electricity consumption.

Response surface methodology

Statistical analysis

RSM is considered a useful statistical technique for designing, modeling, analyzing, and optimizing water and wastewater chemical reactions (Benatti et al. 2006; Bashir et al. 2010). In this study, CCD, as the most widely applied technique in RSM, was utilized in order to optimize the introduced Fe2+ concentration and the VSS removal efficiency. Statistical analysis of the model was carried out to evaluate the analysis of variance (ANOVA) using Design-Expert® 7.0.0 software. The pH value, current density (mA/cm2), H2O2 (mg/L) and retention time (min) were selected as the four main experimental factors in order to evaluate the effect of operational parameters (variable factors) on the responses. Also, it is possible to represent the independent operational parameters and the response in quantitative forms:
formula
(6)
where y is the response, xi and xj are variables, β0 is constant coefficient, βi, βii and βij are the interaction coefficients of the linear, quadratic and the second-order terms, respectively, and finally ej is the error. In this study, the introduced Fe2+ concentration and the VSS removal efficiency data were processed for Equation (6) including ANOVA to obtain the interaction between the process variables and the responses.

Determination of the effective parameters range and experimental design

Considering the theoretical studies and the results of laboratory experiments, a CCD was carried out using selected minimum and maximum levels. The evaluated ranges used in the study were 0–2,000 mg/L for H2O2 concentrations, 0–360 min for retention time, 1–9 for initial pH and 0–4.17 mA/cm2 for current density. Table 3 shows the factors' coded values which were set at five levels: −2 (minimum), −1, 0 (central), +1 and +2 (maximum). The responses are shown as the VSS removal efficiency (%) and the introduced Fe2+ concentration (mg/L).

Table 3

Experimental range and levels of independent variables

Factors Range and levels (coded)
− 2− 10+ 1+ 2
pH (A) 
Current density (mA/cm2(B) 1.04 2.09 3.13 4.17 
H2O2 (mg/L) (C) 500 1,000 1,500 2,000 
Retention time (min) (D) 90 180 270 360 
Factors Range and levels (coded)
− 2− 10+ 1+ 2
pH (A) 
Current density (mA/cm2(B) 1.04 2.09 3.13 4.17 
H2O2 (mg/L) (C) 500 1,000 1,500 2,000 
Retention time (min) (D) 90 180 270 360 

Table 4 shows the results of CCD experiments for evaluating the effect of four independent variables along with the predicted mean and observed experimental results, shown as the VSS removal efficiency and the introduced Fe2+ concentration. The optimum values of the chosen variables were obtained by solving the regression equation and analyzing the response surface contour plots (Noordin et al. 2004). The change independent variables were explained by the multiple coefficients of determination, R2. The model equation was utilized in order to predict the optimum value and subsequently, elucidate the interaction between the factors in the specified range (Elibol 2002). Thirty experiments were conducted in duplicate according to the scheme mentioned in Table 4.

Table 4

The central composite design for the four independent variables

Run no.Experimental design
Results
pH (A)Current density (B)H2O2 (C)Retention time (D)Introduced Fe2+ (mg/L)VSS removal (%)
+1 +1 +1 +1 625 36 
+1 +1 195 25 
+1 +1 +1 625 55 
+1 +1 +1 420 22 
375 43 
350 42 
+2 325 23 
+1 412 15 
10 362 47 
11 +1 +1 +1 205 29 
12 55 15 
13 +1 187 20 
14 325 43 
15 350 43 
16 +1 +1 137 17 
17 +1 +1 212 56 
18 +2 600 45 
19 312 
20 +1 62 22 
21 +1 +1 200 13 
22 +2 725 44 
23 +1 137 13 
24 350 43 
25 +1 +1 +1 625 72 
26 +1 +1 +1 600 19 
27 +1 205 44 
28 
29 350 43 
30 +2 395 40 
Run no.Experimental design
Results
pH (A)Current density (B)H2O2 (C)Retention time (D)Introduced Fe2+ (mg/L)VSS removal (%)
+1 +1 +1 +1 625 36 
+1 +1 195 25 
+1 +1 +1 625 55 
+1 +1 +1 420 22 
375 43 
350 42 
+2 325 23 
+1 412 15 
10 362 47 
11 +1 +1 +1 205 29 
12 55 15 
13 +1 187 20 
14 325 43 
15 350 43 
16 +1 +1 137 17 
17 +1 +1 212 56 
18 +2 600 45 
19 312 
20 +1 62 22 
21 +1 +1 200 13 
22 +2 725 44 
23 +1 137 13 
24 350 43 
25 +1 +1 +1 625 72 
26 +1 +1 +1 600 19 
27 +1 205 44 
28 
29 350 43 
30 +2 395 40 

Analysis of variance

ANOVA was employed to analyze the effect of different factors on the introduced Fe2+ concentration in the system and the VSS removal efficiency. ANOVA results of the quadratic models of the introduced Fe2+ concentration and the VSS removal efficiency are shown in Table 5. The lower p-values (or higher F-values) imply that the addition of higher-order terms might improve the model (Hamsaveni et al. 2001; Noordin et al. 2004; Singh et al. 2011). The ANOVA results showed that two-factor interactions (2FI) and the quadratic model were appropriate enough for the introduced Fe2+ concentration and the VSS removal efficiency, respectively. The high model F-values (42.96 and 24.01) imply the models are significant for the introduced Fe2+ concentration and the VSS removal efficiency, respectively (the associated Prob >F-value lower than 0.05). Also, the values of R2 and adjusted R2 are close to 1.0, which is excellent and indicates a high correlation between the observed and the predicted values. This means that the regression model provides an excellent explanation of the relationship between the independent variables and the responses.

Table 5

ANOVA results of the quadratic models of responses

SourceSum of squaresDfMean squareF-valuep-value
Prob > F
Introduced Fe2+a 
 Model 386196.36 10 38618.36 42.96 <0.0001 (significant) 
 Residual 170739.58 19 89856.06   
 Lack of fit 166268.25 14 11872.92 12.89 0.0058 (significant) 
 Pure error 4.5497.48 90.994   
VSS removalb 
 Model 133195.63 14 9506.83 24.01 <0.0001 (significant) 
 Residual 5938.87 15 395.92   
 Lack of fit 5922.88 10 592.29 185.08 <0.0001 (significant) 
 Pure error 1.6 0.320   
SourceSum of squaresDfMean squareF-valuep-value
Prob > F
Introduced Fe2+a 
 Model 386196.36 10 38618.36 42.96 <0.0001 (significant) 
 Residual 170739.58 19 89856.06   
 Lack of fit 166268.25 14 11872.92 12.89 0.0058 (significant) 
 Pure error 4.5497.48 90.994   
VSS removalb 
 Model 133195.63 14 9506.83 24.01 <0.0001 (significant) 
 Residual 5938.87 15 395.92   
 Lack of fit 5922.88 10 592.29 185.08 <0.0001 (significant) 
 Pure error 1.6 0.320   

aR2 = 0.9598; R2adj = 0.9387; CV = 15.52%; Df = Degrees of freedom; CV = coefficient of variance.

bR2 = 9573; R2adj = 0.9174; CV = 16.89%.

The estimated coefficients of functions were obtained by modifying the models. They are given in Equation (7) for the introduced Fe2+ concentration, and in Equation (8) for the VSS removal.

For the introduced Fe2+ concentration:
formula
(7)
For the VSS removal:
formula
(8)
where A, B, C and D are the four independent variables. The significance of each coefficient present in Equations (7) and (8) was determined by the student's t-test and p-values (Noordin et al. 2004).

Diagnostic plots such as the predicted versus actual values (Figure 3) are useful in order to judge the model satisfaction. The predicted versus actual values plots of parameters are presented in Figure 3(a) and 3(b) for the introduced Fe2+ concentration and the VSS removal efficiency, respectively. In these figures the values of R2 and R2adj were evaluated as 0.9598 and 0.9387 for the introduced Fe2+ concentration, and 0.9573 and 0.9174 for the VSS removal efficiency. These plots demonstrate an adequate agreement between real data and the ones obtained from the models.

Figure 3

Design-Expert® plot; predicted vs. actual values plot for (a) introduced Fe2+, (b) VSS removal efficiency.

Figure 3

Design-Expert® plot; predicted vs. actual values plot for (a) introduced Fe2+, (b) VSS removal efficiency.

Close modal

The results of Design-Expert®

The effect of the operating parameters of pH, current density, H2O2 concentration and retention time on the introduced Fe2+ concentration and the VSS removal efficiency are shown in Figure 4. The obtained results (Figure 4(a)), show that the introduced Fe2+ concentration undergo no significant change in the 3 < pH < 4 range, but in the 4 < pH < 7 range demonstrate a reduction with a significant slope. Further increase in pH values over 5 did not have a noticeable effect on the introduced Fe2+ concentration. As shown in the Figure 4(a), increasing current density would lead to an almost linear increase in the introduced Fe2+ concentration. Also, according to Figure 4(b), increasing retention time would lead to an almost linear increase, while increasing H2O2 concentration will not have a considerable effect on the introduced Fe2+ concentration. In addition, Figure 4(a) and 4(b) shows that the introduced Fe2+ concentration dependency on the retention time and the current density is higher than pH and H2O2 concentration.

Figure 4

Three-dimensional RSM plots of the operational parameters interaction on the responses.

Figure 4

Three-dimensional RSM plots of the operational parameters interaction on the responses.

Close modal

As shown in Figure 4(c) and 4(d), the VSS removal efficiency shows an upward trend with an increase in the current density, the retention time and H2O2 concentration up to about 3.13 mA/cm2, 1,500 mg/L and 180 min, respectively. However, increasing any of these parameters further not only shows no effect on this response but also shows a decreasing trend. In addition, this response shows an increase with pH values up to 3, but at pH values higher than 3 (up to 7) show a decrease from 73% to 31%. Therefore, optimum values of the study parameters were identified for optimum VSS removal efficiency. According to Figure 4, in the optimum operating conditions of the ECP process (pH = 3, current density = 3.13 mA/cm2, retention time = 240 min, and H2O2 = 1,500 mg/L), the VSS removal efficiency would be 74%.

The performance of the ECP process was evaluated in order to remove the VSS content of the waste-activated sludge, in various operational conditions and optimized by RSM. The introduced Fe2+ concentration and the VSS removal efficiencies were considered as parameters that represent the ECP process performance at various pH values, current densities, H2O2 concentrations and retention times (as operational parameters), and the resulting values inserted into the model in order to be optimized by RSM. The results showed that the ECP process was able to obtain approximately 500 mg/L introduced Fe2+ concentration and remove 74% of the VSS content of the waste-activated sludge at its best performance operational conditions (pH = 3, current density = 3.2 mA/cm2, H2O2 = 1,535 mg/L, retention time = 240 min). Also, the energy consumption evaluations showed that the required energy of the ECP reactor is about 1.8–2.5 kWh (kg VSS removed)−1 which is considerably lower than aerobic digestion, a conventional waste-activated sludge stabilization method (about 2–3 kWh (kg VSS removed)−1). The RSM optimization process showed that the best operational conditions of the ECP process agrees with the experimental results. This feature makes it possible to predict the introduced Fe2+ concentrations into the system and the VSS removal efficiency of the process precisely. The results regarding the microbial characteristics of the raw and the stabilized sludge showed that the ECP process is able to remove about 99.9% of the coliforms in the raw sludge during the stabilization process. According to the results, it can be concluded that the ECP is an absolutely environmentally friendly process which is not only able to remove twice the VSS of waste-activated sludge as aerobic digestion in a noticeably shorter retention time, but also consumes noticeably less electrical energy.

APHA, AWWA & WEF
2012
Standard Methods for the Examination of Water and Wastewater
. 22nd edn.
American Public Health Association
,
Washington, DC, USA
.
Abdessalem
,
A. K.
,
Oturan
,
N.
,
Bellakhal
,
N.
,
Dachraoui
,
M.
&
Oturan
,
M. A.
2008
Experimental design methodology applied to electro-Fenton treatment for degradation of herbicide chlortoluron
.
Applied Catalysis B: Environmental
78
(
3
),
334
341
.
Akyol
,
A.
,
Can
,
O. T.
,
Demirbas
,
E.
&
Kobya
,
M.
2013
A comparative study of electrocoagulation and electro-Fenton for treatment of wastewater from liquid organic fertilizer plant
.
Separation and Purification Technology
112
,
11
19
.
Babuponnusami
,
A.
&
Muthukumar
,
K.
2014
A review on Fenton and improvements to the Fenton process for wastewater treatment
.
Journal of Environmental Chemical Engineering
2
(
1
),
557
572
.
Benatti
,
C. T.
,
Tavares
,
C. R. G.
&
Guedes
,
T. A.
2006
Optimization of Fenton's oxidation of chemical laboratory wastewaters using the response surface methodology
.
Journal of Environmental Management
80
(
1
),
66
74
.
Bernal-Martínez
,
L. A.
,
Barrera-Díaz
,
C.
,
Solís-Morelos
,
C.
&
Natividad
,
R.
2010
Synergy of electrochemical and ozonation processes in industrial wastewater treatment
.
Chemical Engineering Journal
165
(
1
),
71
77
.
Canizares
,
P.
,
Paz
,
R.
,
Sáez
,
C.
&
Rodrigo
,
M. A.
2009
Costs of the electrochemical oxidation of wastewaters: a comparison with ozonation and Fenton oxidation processes
.
Journal of Environmental Management
90
(
1
),
410
420
.
Chaplin
,
B. P.
2014
Critical review of electrochemical advanced oxidation processes for water treatment applications
.
Environmental Science: Processes & Impacts
16
(
6
),
1182
1203
.
Chiarenzelli
,
J. R.
,
Scrudato
,
R. J.
,
Wunderlich
,
M. L.
&
Pagano
,
J. J.
2001
Combined steam distillation and electrochemical peroxidation (ECP) treatment of river sediment contaminated by PCBs
.
Chemosphere
45
(
8
),
1159
1165
.
Duesterberg
,
C. K.
,
Mylon
,
S. E.
&
Waite
,
T. D.
2008p
H
Effects on iron-catalyzed oxidation using Fenton's reagent
.
Environmental Science & technology
4
2
(2
2),
852
2
–852
7.
Ghatak
,
H. R.
2014
Advanced oxidation processes for the treatment of biorecalcitrant organics in wastewater
.
Critical Reviews in Environmental Science and Technology
44
(
11
),
1167
1219
.
Gholikandi
,
G. B.
,
Masihi
,
H.
,
Azimipour
,
M.
,
Abrishami
,
A.
&
Mirabi
,
M.
2014
Optimizing stabilization of waste-activated sludge using Fered-Fenton process and artificial neural network modeling (KSOFM, MLP)
.
Environmental Science and Pollution Research
21
(
11
),
7177
7186
.
Ghoneim
,
M. M.
,
El-Desoky
,
H. S.
&
Zidan
,
N. M.
2011
Electro-Fenton oxidation of sunset yellow FCF azo-dye in aqueous solutions
.
Desalination
274
(
1
),
22
30
.
Gutiérrez
,
C.
,
Hansen
,
H. K.
,
Nuñez
,
P.
,
Jensen
,
P. E.
&
Ottosen
,
L. M.
2010
Electrochemical peroxidation as a tool to remove arsenic and copper from smelter wastewater
.
Journal of Applied Electrochemistry
40
(
6
),
1031
1038
.
Hamsaveni
,
D. R.
,
Prapulla
,
S. G.
&
Divakar
,
S.
2001
Response surface methodological approach for the synthesis of isobutyl isobutyrate
.
Process Biochemistry
36
(
11
),
1103
1109
.
Huang
,
Y.-H.
,
Chen
,
C.-C.
,
Huang
,
G.-H.
&
Chou
,
S. S.
2001
Comparison of a novel electro-Fenton method with Fenton's reagent in treating a highly contaminated wastewater
.
Water Science and Technology
43
(
2
),
17
24
.
Kokkali
,
V.
2011
Electrochemical peroxidation of contaminated water and assessment of the toxicity using existing and novel bioassays
.
Lamsal
,
R.
,
Walsh
,
M. E.
&
Gagnon
,
G. A.
2011
Comparison of advanced oxidation processes for the removal of natural organic matter
.
Water Research
45
(
10
),
3263
3269
.
Muruganandham
,
M.
&
Swaminathan
,
M.
2004
Decolourisation of reactive orange 4 by Fenton and photo-Fenton oxidation technology
.
Dyes and Pigments
63
(
3
),
315
321
.
Neyens
,
E.
&
Baeyens
,
J.
2003
A review of classic Fenton's peroxidation as an advanced oxidation technique
.
Journal of Hazardous Materials
98
(
1–3
),
33
50
.
Noordin
,
M. Y.
,
Venkatesh
,
V. C.
,
Sharif
,
S.
,
Elting
,
S.
&
Abdullah
,
A.
2004
Application of response surface methodology in describing the performance of coated carbide tools when turning AISI 1045 steel
.
Journal of Materials Processing Technology
145
(
1
),
46
58
.
Oturan
,
M. A.
&
Aaron
,
J.-J.
2014
Advanced oxidation processes in water/wastewater treatment: principles and applications
.
A Review. Critical Reviews in Environmental Science and Technology
44
(
23
),
2577
2641
.
Ozyonar
,
F.
&
Karagozoglu
,
B.
2015
Treatment of pretreated coke wastewater by electrocoagulation and electrochemical peroxidation processes
.
Separation and Purification Technology
150
,
268
277
.
Pérez
,
J. F.
,
Llanos
,
J.
,
Sáez
,
C.
,
López
,
C.
,
Cañizares
,
P.
&
Rodrigo
,
M. A.
2016
Treatment of real effluents from the pharmaceutical industry: a comparison between Fenton oxidation and conductive-diamond electro-oxidation
.
Journal of Environmental Management
195
,
216
223
.
Shemer
,
H.
&
Linden
,
K. G.
2006
Degradation and by-product formation of diazinon in water during UV and UV/H2O2 treatment
.
Journal of Hazardous Materials
136
(
3
),
553
559
.
Singh
,
K. P.
,
Gupta
,
S.
,
Singh
,
A. K.
&
Sinha
,
S.
2011
Optimizing adsorption of crystal violet dye from water by magnetic nanocomposite using response surface modeling approach
.
Journal of Hazardous Materials
186
(
2
),
1462
1473
.
Sirés
,
I.
,
Brillas
,
E.
,
Oturan
,
M. A.
,
Rodrigo
,
M. A.
&
Panizza
,
M.
2014
Electrochemical advanced oxidation processes: today and tomorrow
.
A Review. Environmental Science and Pollution Research
21
(
14
),
8336
8367
.
Tchobanoglous
,
M. E. I.
1979
Wastewater Engineering: Treatment, Disposal, re-use
, 2nd edn.
McGraw-Hill Book Company
,
New York
,
(07 A MET), 938
.
Vilhunen
,
S.
&
Sillanpää
,
M.
2010
Recent developments in photochemical and chemical AOPs in water treatment: a mini-review
.
Reviews in Environmental Science and Bio/Technology
9
(
4
),
323
330
.
Wang
,
F. Y.
,
Rudolph
,
V.
&
Zhu
,
Z. H.
2008
Sewage sludge technologies
.
Wang
,
C.-T.
,
Chou
,
W.-L.
,
Chung
,
M.-H.
&
Kuo
,
Y.-M.
2010
COD removal from real dyeing wastewater by electro-Fenton technology using an activated carbon fiber cathode
.
Desalination
253
(
1
),
129
134
.
Wang
,
N.
,
Zheng
,
T.
,
Zhang
,
G.
&
Wang
,
P.
2016
A review on Fenton-like processes for organic wastewater treatment
.
Journal of Environmental Chemical Engineering
4
(
1
),
762
787
.
Zhang
,
H.
,
Fei
,
C.
,
Zhang
,
D.
&
Tang
,
F.
2007
Degradation of 4-nitrophenol in aqueous medium by electro-Fenton method
.
Journal of Hazardous Materials
145
(
1
),
227
232
.
Zhou
,
M.
,
Yu
,
Q.
,
Lei
,
L.
&
Barton
,
G.
2007
Electro-Fenton method for the removal of methyl red in an efficient electrochemical system
.
Separation and Purification Technology
57
(
2
),
380
387
.