Abstract
This paper presents a detailed characterization of turbulence in the incoming flow to the clarification component of a water treatment plant, ‘Los Molinos’ (Córdoba, Argentina). The main problems were related to the presence of turbulent flow patterns throughout the treatment, affecting the proper development of the physical processes required for water clarification. Namely: (a) a poor hydraulic design that could produce a non-homogeneous spatial distribution of the flow, recirculation zones and flow stagnation, and a non-uniform discharge distribution among the sedimentation units as a result of different cross-sectional dimensions of the transverse-channel, and (b) high turbulence intensity that affect the flocs' size as well as the efficiency of the settling tanks and filters. Firstly, a detailed in-situ experimental characterization of the turbulent flow was undertaken. An acoustic Doppler velocimeter (ADV) was used to characterize the flow turbulence, whereas for discharge measurements and mean flow velocity field an acoustic Doppler current profiler (ADCP) was employed. Secondly, a numerical model, based on the Reynolds-averaged Navier–Stokes (RANS) equations and the - turbulence closure model, was validated with the experimental data. Finally, based on the results, a diagnosis and recommendations were made for the optimization of the hydraulic design of the water treatment plant.
INTRODUCTION
The optimization of existing drinking water treatment plants has an important significance in satisfying the increasing needs for drinking water of a growing population in large urban agglomerations. The design and evaluation of this type of infrastructure is usually done according to sanitary engineering criteria (Adams et al. 1999). However, hydrodynamic singularities of the flow during the water treatment process can greatly affect their performance due to the incompatible high turbulence flow intensity with respect to the intended sanitarian design.
On the one hand, turbulence is considered as a determining factor in a variety of problems in engineering, for instance the coagulation-flocculation step. It is well known that the floc size is directly related to the Kolmogorov scale and, thus, to the dissipation rate of turbulent kinetic energy. On the other hand, the coagulation-flocculation step is a relevant process in drinking water treatment plants and is used in 95% of such facilities. Therefore, it is important to optimize both the coagulant dosification as well as the hydraulic design in order to minimize the turbulence intensity (and, therefore, avoid floc break) throughout this part of the treatment.
In this context, there is a need to characterize in detail the turbulent flow in the different hydraulic components of water treatment plants in order to evaluate some incompatible tri-dimensional flow patterns with respect to the physical conditions required in the treatment process (e.g. mixing, flocculation and sedimentation).
This paper reports a detailed experimental and numerical characterization of the incoming turbulent flow into the clarification process of the water treatment plant ‘Los Molinos’ (Figure 1) operated by the Aguas Cordobesas SA Company in Bower, near the capital city of Cordoba province, Argentina (from now on, the water treatment plant).
This water treatment plant supplies drinking water to approximately 30% of the population of the city of Córdoba and together with the Suquia water treatment plant supplies drinking water to approximately 1.4 million people.
The main problems observed in the study case are related to the presence of turbulent flow patterns throughout the treatment process that could affect the proper development of the physical conditions required for water clarification. Namely:
- (a)
a poor hydraulic design that could produce a non-homogeneous spatial distribution of the flow, recirculation zones and flow stagnation, and a non-uniform discharge distribution among the sedimentation units as a result of different dimensions of the cross-sections in the transverse-channel (see Figure 1); and
- (b)
high turbulence intensity that could affect the floc's size and the efficiency of the clarifiers and filters.
In order to evaluate the effects of the above mentioned problems on the treatment plant efficiency, a detailed spatial and temporal characterization of the incoming turbulent flow into the clarification component was made for different operational conditions. This characterization has been done by experimental measurements and numerical modeling.
Firstly, the experimental characterization was made with two advanced flow velocity measurement techniques: (a) an acoustic Doppler velocimeter (ADV) that samples high-temporal resolution time series of the three velocity vector components; and (b) an acoustic Doppler current profiler (ADCP) that records vertical profiles of the three velocity vector components.
Secondly, a numerical model, based on the Reynolds-averaged Navier–Stokes (RANS) equations and the - turbulence closure model, was validated with experimental data: comparing mean velocity fields, size and location of the recirculation and stagnation zones, three-dimensional flow structures, values of turbulent kinetic energy (), dissipation rate (), and inflow discharge to each clarification unit. In this study OpenFOAM® (OpenCFD), an open-source toolbox, was used.
There are recent technological and scientific advances dedicated to optimize water treatment processes using in-situ experimental techniques, and so the use of ADV and ADCP techniques begins to be relevant. Garcia & Garcia (2006) have characterized the flow turbulence and the mixing induced by air-bubble plumes in wastewater reservoirs in non-stratified conditions using ADV measurements. Kiss & Patziger (2013) used ADV for a better understanding of flow patterns in a primary sedimentation tank of a wastewater treatment plant. Also, ADCP has been used to characterize the flow in clarifiers describing the key physical processes: hydrodynamics, particle aggregation and floc breaking (De Clercq et al. 2002; Vanrolleghem et al. 2006).
Numerical models have also been an important alternative for studying turbulent flows on hydraulic components of water and wastewater treatment plants (Huggins et al. 2004; Goula et al. 2008; Shahrokhi et al. 2011; Zhang 2014). Most of these works remark the importance of dissipating as much energy as possible in the incoming flow in order to improve the settling tanks' efficiency. So, the design of the incoming flow structures is of great importance, not only to avoid incompatible values of turbulent kinetic energy in the tank, but also to avoid floc breaks and to ensure the settling efficiency of tanks and filters. Also, research has been done about the size and position of baffles and their effects on the inlet flow, in order to minimize recirculation zones and improve the floc removal efficiency (Huggins et al. 2004; Goula et al. 2008; Zhang 2014). The main objective was to establish specific criteria and provide design guidelines for engineers.
More recently, Patziger & Kiss (2015) have calibrated and validated a primary settling tank tridimensional model, based on experimental in-situ measurements (ADV and optical turbidity meter) and settling tests.
Also, Patziger et al. (2016) reported the results of a comprehensive investigation programme on the design and operation of primary settling tanks for wastewater treatment. Removal efficiency, settling properties of primary sludge, internal flow structures within primary settling tanks and the impact on their performance were investigated and evaluated. According to Wei et al. (2016), the flow fields of a pilot Carrousel oxidation ditch can be accurately simulated by LES (large eddy simulation) with the Smagorinsky model, based on experimental validation. They established how to calculate the best submerged depth value in the surface aerators in order to improve the pollutant removal capability and to prevent sludge deposition.
On the other hand, Samstag et al. (2016) provide an overview of CFD (computational fluid dynamics) applied to a wide different range of unit processes in water and wastewater treatment plants. They articulate the state of practice, research and development needs. In addition, they conclude that CFD is nowhere used (except possibly in the disinfection process) as a routine tool for design, risk-management, or troubleshooting. Laurent et al. (2014) presented a protocol to develop more practical and everyday use of CFD models.
Finally, Wicklein et al. (2016) tried to briefly outline the principal features of good modeling practice for wastewater treatment as part of the International Water Association (IWA) investigation work. The main objective was to guide new modelers in the application of CFD studies in the wastewater field.
The aforementioned study indicates that the flow turbulence characterization in water treatment plant components is still a challenge and that it is of great convenience to complement modern experimental techniques with numerical tools in order to obtain a more detailed flow characterization.
It must be emphasized that the validation of the CFD model is crucial. Firstly, CFD can be used for optimizing the hydraulic design and to improve the effluent quality. Secondly, it could increase the basic understanding of internal processes and their interactions. This knowledge can, again, be used for process optimization.
Finally, based on the experimental data and the results of numerical modeling, a diagnosis and several recommendations were made for the optimization of the hydraulic design and the operation of the plant. This validated model is now available as a tool for Aguas Cordobesas SA to apply it to future studies in order to optimize the hydraulic design of the components.
MATERIALS AND METHODS
Six in-situ measurements were performed in order to experimentally characterize the incoming flow to the clarification units, representing six different plant operating conditions; that is, flow discharges between 1.33 m3/s and 2.10 m3/s, according to the acoustic flowmeter installed in the plant. The latter value is above the design water treatment plant capacity, and was due to the strong seasonal variations in drinking water consumption in Cordoba city. The main characteristics of the tested experimental conditions (including the number of operating settling tanks) are reported in Table 1. All the in-situ measurements at the treatment plant are ordered chronologically.
In-situ measurements . | Date . | Number of settling tanks in operation . | Flow depth [m] . | Flow discharge measured by the plant acoustic-flowmeter [m3/s] . |
---|---|---|---|---|
1 | 06/10/2009 | 3 | 0.94 | 1.53 |
2 | 07/09/2009 | 4 | 0.94 | 1.55 |
3 | 09/23/2010 | 4 | 0.95 | 1.33 |
4 | 07/05/2009 | 4 | 0.94 | 1.67 |
5 | 02/15/2011 | 4 | 0.94 | 1.67 |
6 | 07/08/2011 | 4 | 0.94 | 1.87 |
7 | 12/27/2011 | 4 | 0.99 | 2.10 |
In-situ measurements . | Date . | Number of settling tanks in operation . | Flow depth [m] . | Flow discharge measured by the plant acoustic-flowmeter [m3/s] . |
---|---|---|---|---|
1 | 06/10/2009 | 3 | 0.94 | 1.53 |
2 | 07/09/2009 | 4 | 0.94 | 1.55 |
3 | 09/23/2010 | 4 | 0.95 | 1.33 |
4 | 07/05/2009 | 4 | 0.94 | 1.67 |
5 | 02/15/2011 | 4 | 0.94 | 1.67 |
6 | 07/08/2011 | 4 | 0.94 | 1.87 |
7 | 12/27/2011 | 4 | 0.99 | 2.10 |
The turbulent flow in the study area presents large spatial and temporal variations. The characteristic spatial and temporal scales of the largest turbulent structures are estimated about 1 meter and 1 second respectively based on the mean flow velocity values (about 1 m/s) and geometry of the channel (water depth about 1 m), while the smaller spatial scales are expected to be around 0.0001 meter (validated later in this paper). So, the experimental work not only requires measurement techniques that can be applied to large experimental facilities, but also for them to be capable of sampling high spatial and temporal variations in order to obtain relievable flow turbulent parameters (mean velocities, turbulent fluctuations, characteristic scales of the problem, etc.).
Some preliminary tests indicated that the concentration of suspended particles in the flow was appropriate for the use of both acoustic Doppler techniques (García & Herrero 2009). The main characteristics of the experimental techniques implemented in this work are summarized in the following subsections.
Acoustic Doppler velocimetry (ADV)
A MicroADV Sontek® 16 MHz was used, recording time series of the velocity vector components within a measurement volume of 4.5 mm in diameter and 5.6 mm of height and using recording frequencies of up to 50 Hz. During in-situ measurements 1 and 2, specific experimental methods developed by García & Herrero (2009) were applied. Time series were recorded in ten locations in section A-A (Figure 2(a)): five points at 0.25 m and 0.75 m from the flume bottom, and separated horizontally 1 m from each other. In sections B-B and C-C (see Figure 2(a)), sampling was made at four vertical locations across sections' width at three depths from the free surface: 0.07 m, 0.27 m; and 0.67 m. Sections B-B and C-C are located at X-axis 15.25 m; y 21.85 m, respectively. Finally, at locations D and E, flow velocity measurements were performed in the center line (X-axis 22.9 m and 24.7 m in Figure 2(a)) at 0.15 m upstream of each gate, at 0.88 m, 1.28 m and 1.48 m from the transverse-channel bottom. In each section and gates' flow discharges, three-dimensional flow patterns and turbulence intensity were quantified.
Acoustic Doppler current profiler (ADCP)
This acoustic technique provides commonly three-dimensional mean flow velocity information and is used worldwide to characterize turbulent flows in river systems and artificial channels. The ADCP used in this study is a RiverSurveyor S5 YSI/Sontek.
Based on flow depth and mean flow velocity, this ADCP adapts the acoustic pulse scheme in order to obtain high spatial data resolution (with cells up to 2 cm) at 1 Hz frequency. In the in-situ measurements, 3, 4, 5, 6 and 7 vertical velocity profiles were recorded in different locations (see Figure 2(b)): (1) Section F-F (flume cross-section at Y-axis 9.0 m) for discharge measurements, Section G-G (longitudinal section at flume centerline at X-axis 18.55 m), and Section H-H (longitudinal profile at the centerline of the transverse-channel). These measurements provide the mean flow velocity fields (i.e. secondary flows, recirculation zones, etc.). Finally, the inlet flow discharges for each sedimentation tank were quantified using measurements at the center line of the gates 1, 2, 3 and 4 (at X-axis 7.1 m, 8.85 m, 22.9 m and 24.7 m, respectively).
NUMERICAL MODELING OF TURBULENT FLOW
Reynolds-averaged Navier-Stokes (RANS) equations with a - standard turbulence closure model (Launder & Sharma 1974) was used to simulate three-dimensional flow in the study area and to detect recirculation and high turbulence intensity zones.
The ‘Semi-Implicit Method for Pressure-Linked Equations’ scheme (simpleFoam in OpenFOAM®) has been used to solve the Navier-Stokes equations with an iterative process using the finite volume method. The simpleFoam scheme applies to single phase steady flow, with constant density and viscosity (Versteeg & Malalasekera 2007; OpenFOAM Wiki. The SIMPLE algorithm in OpenFOAM).
Here: : the mean i component of velocity vector (i = 1–3), : mean pressure, : water density, : momentum diffusivity (viscosity), : turbulent kinetic energy, : turbulent viscosity,: rate of dissipation of k, : Dirac delta function, : ratio of momentum diffusivity (viscosity) and k diffusivity, : ratio of momentum diffusivity (viscosity) and diffusivity, ,, are - model parameters. In this work, , , , and based on Launder & Spalding (1972, 1974) recommendations as implemented in OpenFOAM®. These parameters have not been modified in this work.
Computational domain
The spatial discretization of the computational domain (Figure 3(a)) has been performed with a mesh of variable volumes. A mesh convergence analysis was performed in order to select a mesh that offered acceptable results with a relatively low computational cost. Near the bottom and walls, volumes are 2.5 cm wide, increasing their width to 3.5 cm, 5 cm and 6 cm towards the center of the domain. The central domain zone contains volumes of equal size. The mesh was densified in the area where the flow has a transition from the flume to the transverse-channel (Figure 3(b)). The structured mesh is composed of 339,976 hexahedrons.
Boundary and initial conditions
Table 2 summarizes the boundary conditions imposed on the computational domain.
Region . | . | . | . | . |
---|---|---|---|---|
Inlet | Mean velocity values measured experimentally in cross-section A-A | Calculated from experimentally measured data in cross-section A-A | Estimated from experimentally measured data in cross-section A-A | |
Outlet | Average static pressure at the faces of the volumes | |||
Wall/bottom | (zero) | kqRWallFunctiona | epsilonWallFunctiona | |
Free surface | Slip |
Region . | . | . | . | . |
---|---|---|---|---|
Inlet | Mean velocity values measured experimentally in cross-section A-A | Calculated from experimentally measured data in cross-section A-A | Estimated from experimentally measured data in cross-section A-A | |
Outlet | Average static pressure at the faces of the volumes | |||
Wall/bottom | (zero) | kqRWallFunctiona | epsilonWallFunctiona | |
Free surface | Slip |
akqRWallFunction and epsilonWallFunction are standard OpenFOAM® wall functions for k y used in wall and bed, see Takano & Moonen (2013) and Robertson et al. (2015).
RESULTS
Validation of the numerical model
The validation of the numerical model was done comparing experimental data and numerical simulation results in sections B-B and C-C (transverse-channel in Figure 2(a)). The data collected in the flume (section A-A in Figure 2(a)) are not included in the validation because the experimental values were used as an inlet boundary condition in the numerical model. Also, to determine whether the observed differences between experimental and numerical results are statistically significant, confidence intervals of the experimental values were used. In this work, the Moving Block Bootstrap (MBB) technique, proposed by García et al. (2006), was used to estimate confidence intervals for different turbulent parameters.
Figure 4(a) and 4(b) compare the numerical model results with the experimental data (from in-situ measurements 2, see Table 1) in both sections, B-B and C-C (transverse-channel). The mean longitudinal-velocity values were similar for the three depths, respectively.
The larger differences are observed for the deepest locations in both sections (B-B and C-C). In these zones, a non-stationary phenomenon occurs that could explain the largest differences found. Figure 4(a) and 4(b) also show that there are large areas in cross-sections B-B and C-C that do not significantly contribute to the main flow and that recirculation affects 50% of the cross-section width. The secondary flow velocity and the streamflow indicate two counterclockwise recirculation cells in section B-B (Figure 4(c)) and two clockwise cells in section C-C (Figure 4(d)).
Figure 5(a) and 5(b) show the results at locations close to gates 3 and 4 (points D and E, see Figure 2). The mean longitudinal flow velocity profile (incoming flow to each gate) resulting from the numerical model and the one recorded with the ADV are quite similar.
The mean inlet velocity at gate 3 is 50% smaller than at gate 4, so the inlet discharge at settling tank 4 is larger and thus has a smaller detention time All this results in a lower floc removal efficiency.
Table 3 summarizes the maximum values of k from the experimental data and the ones from the numerical model for flow conditions 2 (see Table 1). The experimental values k have been computed using the observed values of velocity variances while the numerical values have been computed using the standard - model. The numerical data indicate the maximum value of each section.
Section . | Experimental . | Numerical . |
---|---|---|
Flume | 50 ± 5 | 50a |
Section B-B | 128 ± 13 | 191 |
Section C-C | 494 ± 44 | 554 |
Gate 3 | 369 ± 37 | 385 |
Gate 4 | 339 ± 51 | 447 |
Section . | Experimental . | Numerical . |
---|---|---|
Flume | 50 ± 5 | 50a |
Section B-B | 128 ± 13 | 191 |
Section C-C | 494 ± 44 | 554 |
Gate 3 | 369 ± 37 | 385 |
Gate 4 | 339 ± 51 | 447 |
aBoundary inlet flow condition.
This table also includes confident intervals estimated using the MBB method. Even though the experimental and numerical values of k are statistically different in sections C-C and in gates 3 and 4, both sets of data show similar trends: k values near the gates and in section C-C are one order of magnitude larger than the values of k in the incoming flow (flume). This observation does not agree with standard sanitary design guidelines.
The observed differences in the k values in section C-C, gates 3 and 4, can be due to the outlet boundary condition used: an average static pressure at the faces of the volumes. This is not completely true, since flow changes over time imply changes in the total pressure values. It is important to mention that a -Omega SST model was used for the same domain and no significant improvements were observed in the velocity distribution and absolute k values.
Section . | Experimental . | Numerical simulation . |
---|---|---|
Flume | 2.19 | 7.7 |
Section B-B | 42.66 | 115.3 |
Section C-C | 414.54 | 310.85 |
Point D | 162.42 | 212.4 |
Point E | 20.68 | 119.3 |
Section . | Experimental . | Numerical simulation . |
---|---|---|
Flume | 2.19 | 7.7 |
Section B-B | 42.66 | 115.3 |
Section C-C | 414.54 | 310.85 |
Point D | 162.42 | 212.4 |
Point E | 20.68 | 119.3 |
The values of from the experimental observations were estimated as , where L is the scale of the largest eddies present in the flow. Scales L were estimated from the correlation analysis of temporal flow velocity signals at each location and Taylor's Frozen approximation (Garcia & Garcia 2006). The numerical values of have been computed using the standard - model. Comparisons of the numerical and experimental values of show a very good agreement and therefore indicate the relevance of the use of CFD models in this type of problem.
This statement can also be demonstrated by analyzing the values of the average velocity gradient value (). This is a parameter generally used in sanitary design and can be estimated based on and Z (kinematic viscosity of the fluid), as follows:. In the sections A-A and B-B, values are in the order of 20–80 Hz, which is acceptable for flocculation to occur (Tambo & François 1991). However, in section C-C the values are significantly higher than in section A-A. Thus, turbulence could cause the breakage of the flocs generated in the mixing chamber. Previous studies show that the size of the flocs formed in the flocculation process (with equal to 50 Hz) decays to a minimum size when the particles are subjected to values of 100, 300 and 500 Hz after 1 minute. The latter values are similar to those found in the B-B and C-C sections, and in gates 3 and 4 of the treatment plant. Finally, the presence of particles of smaller size and weight generates low efficiency of the sedimentation tanks with floc volumes extraction below those provided in the design.
Figure 6 shows a good agreement by comparing the observed and simulated longitudinal flow velocity field for the in-situ measurement 6 (see Table 1), along section G-G.
It can be observed that the numerical model correctly represents the observed zones of flow stagnation (flow velocities close to zero) in the region between Y-axis 0 (wall of the transverse-channel) and 0.5 m. Something similar occurs downstream of the central pile of the gateway (Y-axis 9.5 m).
Transverse-channel data were recorded with the ADCP during the in-situ measurement 6 in section H-H (see Figure 2(b)). Figure 7 compares the flow velocity magnitude for the transverse-channel. Similar patterns are observed in both measured and simulated areas of stagnant flow and velocity magnitude. Note that the transverse-channel has a large region of stagnant flow (flow velocity magnitude close to zero), 6 m to the left side (X-axis 6 m in Figure 7) and 5 m to the right side (X-axis 26 m in Figure 7).
As a summary of the numerical model validation it can be stated that: (a) the experimental data collected in the flume were successfully used as boundary conditions for validating the numerical model; (b) the open-source toolbox OpenFOAM® adapts to the problem in an appropriate way and indicates the relevance of using CFD models in this type of study case; (c) the use of a rigid lid at the free surface was allowed to solve the problem without requiring the use of a two phase flow simulation scheme with a consequent reduction in complexity in the numerical model; (d) the numerical model accurately reproduces the average values of flow velocities (characterizing flow stagnation and acceleration zones), and the largest differences were found in the recirculation zones where a non-stationary phenomenon occurs; (e) the model accurately simulates the spatial evolution of k.
Analysis and optimization of water treatment plant operation
In this case, the smaller largest observed in sections B-B and C-C indicates that the flocs formed in the mechanical agitators located upstream in the treatment plant would break in these sections.
Once the numerical model was validated, it was used to simulate two operating conditions of the water treatment plant and to characterize the flow stagnation and acceleration zones as well as the spatial evolution of k and .
Firstly, the case where the treatment plant operates with 3 settling tanks was numerically modeled; that is, while one settling tank is under maintenance (tank cleaning, for example). The results were compared with the results in normal operating conditions (4 settling tanks working).
Figures 8 shows values of the velocity field for the hydraulic conditions obtained in in-situ measurement 1 in the study area, when the treatment plant operates with three sedimentation tanks: Figure 8(a)–8(c) for settling tank 1, 2 or 3 under maintenance, respectively. These figures show an increase in the velocity value in the opposite branch of the transverse-channel where the settling tank is out of service, owing to a redistribution of the discharge among the three operating tanks. Also, the maximum k values are in the order of 600 cm2/s2 in the transverse-channel and the order of 1,000 cm2/s2 at the gates. These values are larger than the recommended maximum values for normal operating conditions (four settling tanks, see Table 3). These results indicate that it would be recommended to perform maintenance and cleaning tasks firstly on tanks 1 and 2, and then on tanks 3 and 4.
Secondly, the treatment plant was modeled in an emergency situation; that is, only settling tanks 3 and 4 are in use, while a gate at the end of the right side of the transverse-channel is opened and settling tanks 1 and 2 were bypassed. The outflow at the right gate is then mixed with a coagulant and goes directly to the filtering process.
Figure 8(d) shows the flow velocity field resulting from the simulation of this operational condition. Velocity magnitudes in gates 3 and 4 are similar to those for the normal operating conditions and the k values indicate that flocs reach their smaller size on the gates of sedimentation tanks 3 and 4.
The experimental and numerical characterization presented up to here indicates that geometric modifications are needed in the transition zone from the flume to the transverse-channel and in the gates, since in these zones the flocs break into smaller particles and, therefore, decrease the settling tanks' efficiency.
It is important to highlight that the validated CFD model is now available for the Aguas Cordobesas SA Company to apply in future hydraulic design optimization studies for the water treatment plant ‘Los Molinos’.
CONCLUSIONS
In this work, experimental and numerical characterizations of the incoming flow to the clarification component of the water treatment plant ‘Los Molinos’, Córdoba, Argentina, has been presented.
The experimental characterization has been performed using advanced flow velocity measurement techniques; that is, an ADV and an ADCP. Both these techniques provide valuable information not only for turbulent flow characterization, but also for the definition of boundary conditions and thus helping the validation of the numerical model used.
The results of the experimental work show a strong three-dimensional flow with high turbulence intensity in sections B-B and C-C, and a strong flow separation zone that affects 50% of the cross-sectional width. Turbulent kinetic energy values in that zone are one order of magnitude larger than those observed in the upstream flume cross-section, and thus the Kolmogorov length scale reaches its minimum value.
At this point the flocs break into smaller particles, inducing a lower efficiency in the sedimentation tanks, with floc volume extractions below those provided in the design manuals.
A numerical vertical Reynolds-averaged Navier-Stokes (RANS) equations model was employed, using a - standard turbulence closure. This numerical model accurately reproduces the mean flow velocity values (characterizing flow stagnation and acceleration zones), the spatial evolution of turbulent kinetic energy and the dissipation rate. This indicates that a RANS - model (with sufficient mesh resolution) is a valid engineering tool in order to obtain turbulence characteristic parameters such as k and , directly related to the floc size. The largest differences between experimental observations and numerical results were found in the recirculation zones where non-stationary phenomena occur.
It should be stated that the use of a rigid lid at the top surface allowed solving of the problem without requiring the use of a two-phase flow simulation scheme; that is, with a consequent reduction in numerical model complexity
Also, the open-source toolbox OpenFOAM® was shown to accurately represent the observations and so indicates the relevance of the use of CFD models in this type of study case.
Further, the validated model was used to simulate two different operating conditions: (a) the treatment plant operating with only 3 settling tanks while one was under maintenance (tank cleaning, for example); and (b) the treatment plant operating in an emergency situation with only two settling tanks (settling tanks 1 and 2 were bypassed).
Both the experimental and the numerical characterizations presented indicate that geometric modifications are needed in the transition zone from the flume to the transverse-channel and in the gates, because in these zones the flocs break into smaller particles and therefore decrease the settling tanks' efficiency.
Finally, the validated CFD model is available for Aguas Cordobesas SA company to be applied in future studies for hydraulic design optimization in ‘Los Molinos’ water treatment plant.
FUTURE RESEARCH
We strengthen the need to incorporate a sediment transport model and a floc breakage model in order to improve and to complement the characterization of the problems observed in the areas upstream of the clarification components.
ACKNOWLEDGEMENTS
The authors would like to thank the manager staff as well as the professionals and technicians from Aguas Cordobesas SA responsible for operating the water treatment plant ‘Los Molinos’, near the town of Bower, province of Córdoba, Argentina. Authors would also like to thank the Secretary of Science and Technology of the National University of Cordoba (SECyT-UNC) and the National Council for Scientific and Technological Research (CONICET) for funding this project.