Abstract
A 16-month monitoring program was conducted on a prototype sanitary system in a coastal city in China. The groundwater infiltration (GWI) on dry weather days and the rain-derived inflow and infiltration (RDII) on wet weather days were quantified and analyzed. The proportion of monthly averaged GWI to total flow can be as high as 70% during the observation period mainly due to the high groundwater level. The results also show that the ratio of RDII volume to total rainfall volume (defined as R-value) reaches a limited value of approximately 10% for the studied system when the total rainfall depth increases. A reference indicator Rlim for the limited R-value was proposed for assessing the conditions of sewer systems in terms of RDII. The Rlim value depends on local sewer conditions and in general, a lower Rlim value represents a better performance on RDII and vice versa. This study enriches the case studies on the performance of a specific sanitary sewer system on inflow and infiltration in a typical coastal city with exceptionally high groundwater levels, excess rainfall events in the monitoring season and possible typhoon events, which addresses the unique locational and hydrological properties of a representative coastal city.
HIGHLIGHTS
The time-period for the ‘minimum night flow method’ should be adjusted accordingly.
High infiltration due to high groundwater levels was observed specifically for the study site.
The ratio of RDII volume to total rainfall volume (R-value) tends to be limited as rainfall increases for all RDII events.
The limited R-value for high rainfall events was proposed for assessing the performance of sewer systems.
INTRODUCTION
Urbanization has resulted in the rapid development of urban drainage systems in cities around the world. The total length of urban drainage systems including sanitary, storm, and combined systems in China has almost doubled in the last decade from 439,000 km in 2012 to 803,000 km in 2020 (National Bureau of Statistics of China 2022). Due to ageing systems, defects in sewers, illicit connection and other factors, extraneous water enters the sewer systems causing sewer inflow and infiltration (I/I) which mainly consists of groundwater infiltration (GWI) and rain-derived inflow and infiltration (RDII). The RDII is generally composed of rainfall-derived inflow (RDI) and rainfall-induced infiltration (RII), where RII is also called delayed infiltration in terms of the flow response time of stormwater infiltration which is between the rapid response of stormwater direct inflow and the slow response of GWI (Sowby & Jones 2022).
The extraneous water increases hydraulic loadings of sanitary sewers and wastewater treatment plants (WWTPs). In extreme cases, the I/I volumes can even be higher than the wastewater volume (Bertrand-Krajewski et al. 2006), which affects the pollutant removal efficiency of WWTP and results in additional costs in processing the wastewater (Ellis &Bertrand-Krajewski 2010; Dirckx et al. 2016; Jenssen Sola et al. 2018). In China, the inflow and infiltration generally dilute the sewage and cause low chemical oxygen demand (COD), which may cause issues in the WWTP. Inflow and infiltration can also cause the volume of water in the sanitary network to exceed the maximum operating capacity and cause sanitary sewer overflows (SSOs) incidents, especially during rainfall events (Crawford et al. 1999; USEPA 2007). Furthermore, the GWI can flush the surrounding soil into the sewer system, accelerating the structural deterioration, and causing sinkholes or surface settlements due to soil erosion around the defective sewers (Kracht et al. 2008; Guo et al. 2013). The studies above illustrate that the negative impacts of I/I on the urban environment and municipal infrastructure can be significant. The I/I level can be used as an indicator to characterize the integrity of the pipe network (Zhang et al. 2018). However, due to the influence of many factors such as the drainage regulations, physical conditions of the pipes and rainfall patterns, it is generally difficult to quantify the amount of extraneous water (Karpf & Krebs 2011).
Using qualitative methods to roughly evaluate the sanitary system is an effective strategy to reduce the amount of workload and costs (Thapa et al. 2019). Generally, physical methods (e.g. visual and odor inspection, dye testing or smoke testing, closed circuit television (CCTV) inspection and temperature sensing) are used to qualitatively analyze the inflow and infiltration in sewer systems (Hoes et al. 2009; Irvine et al. 2011). Shehab & Moselhi (2005) developed an automated system based on pattern recognition, image analysis and artificial intelligence techniques to automatically detect and classify infiltration of sewer pipes. An increasing number of artificial intelligence (AI) technologies have also been developed to analyze CCTV images for characterizing sewer defects in recent years (Cheng & Wang 2018; Zhou et al. 2022; Sun et al. 2023). Tracer methods (e.g., chemical tracer, biological markers, and stable isotope) based on material balance have been proven to be accurate in quantifying I/I (for example in Mattsson et al. 2016; de Ville et al. 2017; De Bondt et al. 2018; Zhao et al. 2020). Kracht & Gujer (2005) and Kracht et al. (2007) successfully applied COD and stable isotope as tracers to quantify infiltration in the sewer systems in Europe, respectively. Zhang et al. (2017) applied four tracers for accessing RDII and concluded that conductivity has the best reliability and sensitivity for RDII simulation compared with the other three tracers including COD, , . The key to this type of method is to find a reliable tracer or combination of tracers in local wastewater or extraneous water.
With respect to quantitatively analyzing methods on I/I, Weiß et al. (2002) proposed the ‘triangle’ method and ‘moving-minimum’ method in the study of 34 combined sewage systems in Germany. The ‘triangle’ method assumes that the domestic sewage flow is constant in a certain period. Therefore, this method can only obtain the average I/I, and the variation of the infiltration process over time is not shown by this method. The ‘moving-minimum’ method assumes that the sum of the sanitary sewage plus I/I on any day is equal to the minimum daily flow in the 21 days before the day of concern, but this method lacks physical background. Due to the diurnal pattern of domestic water use, the minimum effluent flow generally occurs at night, and the ‘minimum night flow method’ was applied for quantifying I/I based on the flow-based method (Ellis & Bertrand-Krajewski 2010). It is based on the assumption that the GWI rate is roughly close to the minimum night flow (Kracht et al. 2008). De Bénédittis & Bertrand-Krajewski (2005) studied the uncertainty of infiltration estimation using the ‘minimum night flow method’ and found that a sufficient duration of dry weather days was needed to ensure the accuracy of this method. A sufficient observation time can reduce the uncertainty to about 10% as indicated in De Bénédittis & Bertrand-Krajewski (2005). A number of hydraulic model-based methods have also been proposed for I/I analysis (Li et al. 2008; Karpf & Krebs 2011). Liu et al. (2021) proposed a statistical model based on logistic regression to predict the probability of GWI. Machine learning was used to calibrate, validate, and test the model. Model influence parameters were determined as pipe material, size and shape, soil condition, and groundwater level.
With respect to field monitoring studies, Zhang et al. (2018) estimated the inflow and infiltration for three rainfall events in a separate sanitary sewer system. Chen et al. (2022) conducted a similar monitoring campaign to studying the inflow and infiltration in an aged residential compound in China, which was retrofitted from a combined to a separate system during the monitoring period. It was found that the inflow and infiltration characteristics are different in different types of drainage systems. Water balance methods or flow-based methods are suitable for closed systems. However, when there are overflows, this method will produce errors, because the method does not take into consideration the water exiting the system (Jenssen Sola et al. 2018). For more complex pipe connections, the installation location of the monitoring equipment can be determined after simulation with software such as storm water management model (SWMM). In the study of Chen et al. (2022), the placement of the water level meters was determined based on SWMM simulation. Moreover, the local error of the I/I assessment method needs to be considered for field studies. For example, for the tracer method, it is necessary to investigate the maximum residence time in the pipeline and the potential deposition of markers used in the catchment area of the study area (Xu et al. 2016; Yang et al. 2021).
The above studies mainly focused on general understandings of I/I in inland cities. For coastal cities, the performance of the sewer systems may be different due to the high groundwater level, excess rainfall, possible typhoon events and hence assessing the I/I under extreme conditions is necessary. The study area is a coastal city, Ningbo, Zhejiang province, in east China which experiences abundant total annual precipitation (average of the multi-year total annual precipitation 1,525 mm), with large seasonal differences in rainfall, susceptible to short-term heavy rainfall in summer and autumn under the influence of typhoons, and 60% of the total annual precipitation in the main flood season from May to September (Ningbo Meteorological Service Center (accessed 30 March 2023)). The general impact of groundwater or specific rainfall events on a prototype sanitary system is therefore to be assessed. The present study mainly focuses on the relationship and pattern of the response of hydraulic operating parameters, such as flow and water depth in a prototype sanitary sewer system, to external conditions, such as rainfall and groundwater level. The goal is to find a method to assess the performance of inflow and infiltration of a prototype sanitary sewer network in a coastal city. This study enriches the case studies on the performance of sanitary sewer systems on inflow and infiltration and may provide key references for inflow and infiltration management in coastal regions.
MATERIALS AND METHODS
Site description
Data acquisition and preparation
An online flowmeter THWater Smart Drainage Monitoring Flowmeter (THWater Official Site (accessed 16 June 2023)) was installed at the monitoring location WF1. The flow meter was able to measure both flow rate and velocity as well as water depth. It has a velocity measurement resolution of 0.001 m/s, an accuracy of 0.03 m/s, range of ± 6 m/s. The flow meter was well maintained and pre-calibrated with a HACH FL900AV Flow Meter (HACH Official Site (accessed 16 June 2023)) before installation. This type of flow meter also measures water depth at a resolution of 0.001 m and a range of 10 m. The sampling frequency for the monitoring program was one sample per minute for both velocity, flow rate and water depth. Precipitation and groundwater data were collected from the local hydrology department with a measurement resolution of 0.5 mm at 5 min and 0.01 m at 1-day intervals, respectively. The invert elevation of WF1 was 2.348 m below sea level.
The dates for dry weather flow were selected based on the rules of Karpf & Krebs (2011) and Staufer et al. (2012) where the dry weather days are defined as the rainfall intensity under 0.3 mm/day for the day and the day before in order to exclude the contribution of stormwater runoff to the measured flow rate. A total number of 105 dry weather days was selected. A wet weather day was defined as a period containing a rainfall event with more than 2 mm of precipitation in a 6-h period (Rezaee & Tabesh 2022). A total number of 15 rainfall events were identified for the analysis of RDII, one of which was affected by a typhoon event.
RESULTS AND DISCUSSIONS
Dry weather flow and GWI
At the study site, the flow rate showed a downward trend from 2:00–4:00. In the literature, the time-period used for the ‘minimum night flow method’ for GWI analysis was 2:00–4:00 or 0:00–6:00 in Ellis & Bertrand-Krajewski (2010) and Chen et al. (2022) respectively. In this study, it was found that the lowest flow rate in individual days occurred between 4:00 and 6:00. Although 6:00 shows the lowest average flow rate, it is still believed that the period of 4:00–6:00 should be used for a more general coverage of days of the lowest flow rate in a day. It was proposed in this study that the time-period for this specific location for the ‘minimum night flow method’ should be adjusted to 4:00–6:00 for GWI analysis. In general, the proper time-period of application of this method should be adjusted by local actual field monitoring. This could be explained by the different local properties of groundwater level, pipe condition, residents' water usage pattern, and the size of the sewer system.
The typical value of average daily water usage in megacities of China is 210–340 L per capita per day (LPCD) according to regional design guidelines (Ministry of Housing & Urban-Rural Development of the People's Republic of China 2018). Assuming the GWI accounts for 70% of the total flow, the service area corresponds to a population of approximately 1,200–2,000, which is roughly in accordance with the occupancy of the built dwellings in this area. Two time series, November 10 to 28, 2021 and December 4, 2021 to January 8, 2022, were selected for cross-correlation analysis between daily GWI rate and daily groundwater level. The cross-correlation analysis did not yield valid results for both time series data mainly due to the less variation of groundwater level and GWI value on a daily scale. The GWI usually depends on factors such as groundwater level, soil characteristics and sewer conditions (Karpf & Krebs 2011; Thapa et al. 2019; Liu et al. 2021). The effect of high groundwater levels on the GWI is a very important influencing factor in this study area. The sanitary sewer system operates at a high groundwater level, resulting in a high infiltration due to seepage phenomena, as the water level in the network is well below the groundwater level. Groundwater level and infiltration rate generally do not fluctuate over time in this sewer network, and the influence of their variations could not be observed. Theoretically, under certain physical conditions of the network, the infiltration into the sewer network and the difference between the water level of the pipes and the groundwater level should satisfy a certain relationship such as Darcy's law and be positively correlated. But in the present sewer network it is not possible to observe it due to less variation.
There are two other reasons for the high percentage of infiltration. First, the ‘minimum night flow method’ calculates the infiltration volume based on the infiltration rate as a constant value, but the infiltration rate actually varies over time, which causes errors. In a previous study, the infiltration volume of a month obtained based on this method was 71 and 93% higher than the results of the ‘triangle’ method and ‘moving-minimum’ method on their studied catchment (De Bénédittis & Bertrand-Krajewski 2005). Second, most of the residential buildings in the study area are newly built or under construction, the total daily sewage discharge is relatively low due to few permanent residents, and the denominator is small when calculating the infiltration percentage.
Quantification of RDII in selected rainfall events
Representative rainfall events were selected to estimate the impact of RDII of the studied system during the monitoring period at the monitoring site WF1. The raw flow data obtained per minute was hourly accumulated. As dry weather flow was relatively stable, selecting two dry days' flow in the vicinity of a rainfall event can effectively represent the base flow at the time of the rainfall event, and hence the flow in the system two dry days before or after the rainfall events was selected as the reference flow. In this study, the time-period of RDII is defined as: from the beginning of the rainfall with instantaneous intensity higher than 0.5 mm/h to the time when the flow in the system decreases and reaches 97% of the reference flow and lasts for 2 consecutive hours. The time-period of flow increase during a rainfall event was defined as the rainfall event dominant period, while the period dominated by infiltration was defined as the time-period after the main rainfall period of rainfall events until the whole RDII process ends. Meanwhile, the real-time water depth was compared with the corresponding water depth in reference dry weather days (reference water depth) for auxiliary assessment.
In Figure 6(b), the total rainfall depth was 21.5 mm, and the rainfall started at 0:00 on November 29, 2021 and ended at 4:00 on the second day with a total duration of 13 h and a maximum rain intensity of 5 mm/h at 10 h after the start of the event. The total rainfall volume was 6,880 m3. The flow rate exceeded the dry weather reference flow rate about 2 h after the start of the rainfall at point A in Figure 6(b). The maximum flow increase rate was at point B and the flow rate was 21 L/s to a peak. The RDII process lasted for about 48 h to end at point D and the total RDII volume was 686 m3. The R-value was calculated to be approximately 10.0%. The flow increase dominated by rainfall events obviously lasted approximately 18 h and dominated by infiltration for about 28 h after the main rainfall period of the rainfall event (at point C). The water depth response was observed when the rain intensity reached 1.5 mm/h (cumulative rainfall depth reached 3 mm) and the water depth was higher than the reference, and it was maintained for only 16 h.
It should be noted that specifically in Figure 6(c) and 6(d), it was not straightforward to determine the onset of flow response by observing the change in absolute values, so the gradient of the flow curve for the RDII process and the corresponding referenced dry weather flow curve were calculated and the difference in the trend of the curve change was used as an indicator of the initiation of the RDII response. In Figure 6(c), the rainfall event started at 2:00 on January 9, 2022 and ended at 1:00 on the second day for 9 h with a total rainfall depth of 8 mm (volume of 2,560 m3). Calculation of the slope of the flow curve showed that the flow in the sewer began to show an obvious steep upward trend 4 h after the start of the rainfall at point A in Figure 6(c). The flow continued to increase reaching a maximum value of about 30 L/s at point B after 17 h, after which the flow began to decrease and entered a period dominated by infiltration after the end of the rainfall (at point C). In this case, the time-period of flow increase dominated by rainfall events occupied the vast majority of the time-period of the RDII process due to the relatively small rainfall totals and low rainfall intensity except for the first hour of the rainfall event. The RDII process lasted for approximately 26 h to end at point D and the RDII volume was 257 m3. The R-value was approximately 10.1%. The rainfall event started with a rain intensity of 2 mm/h, and the water depth soon responded significantly and lasted for 22 h.
In Figure 6(d), the total rainfall depth was 79.5 mm, the rainfall started at 17:00 on March 20, 2022 and ended at 18:00 on March 22, 2022, with a rainfall duration of 43 h and a maximum rain intensity of 7 mm/h at 14 h after the start of the event. The total rainfall volume was 25,440 m3. The flow rate was already slightly greater than the dry weather reference flow rate before the rainfall started. After calculating the slope of the flow curve, it was found that the flow response started to appear 1 h after the start of rainfall at point A in Figure 6(d). The RDII process ended at point D and the RDII volume was 1,455 m3. The R-value was calculated to be approximately 5.7%. There were multiple flow peaks during the RDII process, with the maximum flow increase rate at point B. In this case, the rainfall event was of long duration and high intensity. The period of flow increase dominated by rainfall event obviously lasted approximately 49 h and dominated by infiltration for about 15 h after the rainfall event (at point C), which was related to characteristics of rainfall events. The water depth was a visible rise when the rain intensity reached 7 mm/h (cumulative rainfall depth 16.5 mm), and this high water depth remained for period of time until after the flow had already returned.
The initial water depth response for the above four rainfall events occurred when the instantaneous rainfall intensity reached 3, 1.5, 2, and 7 mm/h, and the corresponding cumulative rainfall depth was 4, 3, 2, 16.5 mm, respectively. The duration of high water depth receding at the end of rainfall is related to the duration of high-intensity rainfall during the rainfall process and increases with the latter. At this stage, the water content of the soil was high due to the high groundwater level in the study area. With relatively low permeability, the surface runoff generates relatively quickly causing more water to enter the system via surface openings such as manhole covers. The relatively small diameter of the storm sewer ranging from 500 to 700 mm in the separate drainage system leads to insufficient drainage capacity. The longer the duration of high rainfall intensity, the more the surface water accumulates, which cannot be drained by storm systems efficiently. Due to the limited capacity of sanitary sewers, the rapid flow increase caused by rainfall events with high intensity resulted in a significant volume increase in the sewer system. The rainfall-derived flow in the studied system did not always coincide with the water depth variation in the manhole given the full pipe flow condition in this study due to the unique properties of the coastal city on groundwater level, and precipitation patterns.
In this study, for the majority of rainfall events, the time lag between the initial flow response of the sanitary sewer system and the rainfall was 1–2 h. Chen et al. (2022) found the time of response generally within the range of 30–40 min in the RDII study of a combined sewer system in Ningbo, and this difference is mainly due to the different types of drainage systems, service area of the systems and runoff coefficient. Although the catchment area of the study area is relatively small, the service area of Chen et al. (2022) was only about a quarter of this study. This could be one reason why the initial flow response was faster. Based on the physical background, the component of increased flow during a rainfall event is mainly rain-derived inflow (RDI), and after a rainfall event is rainfall-derived infiltration (RII). The total rainfall depths for the rainfall events in Figure 6(a) and 6(b) were approximately the same, but there are significant differences in the characteristics of rainfall. The R-values calculated are similar for these two events. For a long-duration but low-intensity rainfall event, the R-value will be slightly lower. The contribution of RDII to the total flow was 21, 20, 14, and 26% and the calculated R-value was 9.1, 10.0, 10.1, and 5.7% respectively for the examples in Figure 6(a)–6(d).
For Figure 8(b), the R-value curve in this study stays at a relatively stable value at about 10% (±5%) for the study area, while the results of Chen et al. (2022) before system upgrade increased with the total rainfall and reached about 25% (±5%). For the separate system in the present study, the defects of sewers have a maximum capacity for extraneous water to enter, but this capacity is relatively small. Although the amount of RDII increases with the total rainfall, the percentage of volume that enters the sanitary sewer system is limited to about 10% of the total rainfall volume for the studied system regardless of the rainfall intensity. The fluctuations of R-values may be related to factors such as rainfall patterns and subsurface conditions. For the result of Chen et al. (2022) after the system upgrade, the R-values reduced to a lower range at about 10% (±5%). For Zhang et al. (2018), the R-value curve shows a decreasing trend with the increasing total rainfall. This means that the system is probably in a better condition with a lower R-value when the rainfall increase. The curve of the separate system in Zhang et al. (2018) shows a downward trend which is contrary to the combined system in Chen et al. (2022) (before the upgrade) and the present study. According to Zhang et al. (2018), although the total volume of RDII increases with the rainfall volume (Figure 8(a)), the ratio of the volume of rainfall entering the sewer system to the total rainfall volume decreases with the rainfall volume.
Although only one monitoring point was used in this study, the upstream of this sanitary sewer system has good independence and all the flow from the upstream passes through this monitoring point. For larger sanitary networks, selecting monitoring points according to the catchment area will provide more desirable effects. For this study, the analysis is only for a specific sanitary sewer system. For other systems, the performance will be different, but the general trend should be similar. The capacity for extraneous water in a sewer system is limited. When the rainfall exceeds a certain level, it will reach a limited situation which can be defined as Rlim in this study. For the current system, the limited capacity Rlim is 10% (±5%). This capacity mainly depends on the maximum hydraulic capacity of the system itself, the distribution of the number and location of defects and the percentage of RDII entering the system by different paths.
Similarly, the value of Rlim is about 25% in the combined system in Chen et al. (2022) before the upgrade and about 10% after the upgrade. The different Rlim values may be the results of the type and physical condition of specific systems, differences in the path of extraneous water entering the system and the ageing of the systems. For a specific sewer system, if the Rlim is rising, it means that the condition of the system is deteriorating and vice versa. The RDII into the local separate sewer system may be in a similar situation, the Rlim values of this study and Chen et al. (2022) after upgrade are both approximately 10%, which requires further exploration such as a quantitative comparison of the physical conditions between the two systems. For the above discussion, a reference indicator Rlim can be proposed to assess the conditions of sewer systems in terms of RDII. In addition, in the study of Chen et al. (2022), the results of inflow and infiltration can be measured in rainfall events with rainfall amounts above 5 mm due to surface ponding, and interception by flat roots and vegetation. In this study, rainfall events less than 5 mm during the observation period were also observed in the selection of rainfall events for the study, and it was found that the flow did not show a significant response mainly due to a lack of surface runoff.
Nevertheless, the current study has not fully explored the surface runoff generation and how it enters the sanitary network and locating the defects in the sewer system for inflow and infiltration has not been discussed yet. They will play an important role in the efficient operation and maintenance management of the pipe network in the future. Therefore, the next step will be to explore how to directly measure inflow and infiltration and determine the degree and location of the defects.
CONCLUSION
In the present study, the performance of a sanitary network in a coastal city in China was assessed after a 16-month long-term monitoring. Under dry weather conditions, there is a diurnal flow variation in the study area throughout the observation period. On dry weather days, infiltration was found to be as high as 70% of the total flow under high groundwater levels. On wet weather days, the proportion of RDII was lower than that of GWI for most of the rainfall events in this study, except for typhoon events. It was found that the ratio of the rainfall volume entering the sewer system will reach a limited value when the total rainfall depth increases. This study proposed a reference indicator Rlim which is the ratio of rainfall volume entering the sewer system to the total rainfall volume for assessing the conditions of sewer systems in terms of RDII. A higher Rlim indicates that the sewer system has a high proportion of water entering the system during storm events, and hence the condition of the system is poor.
Distinguishing the volumes corresponding to RDI and RII from the RDII volume is a limitation of this study. For further work, the accuracy of the RDII flow response can be improved by studying more rainfall events and introducing water quality parameters (e.g. conductivity and COD) based on the material balance equation to solve for the extraneous water quantity. Nevertheless, the results obtained from this work can provide technical support for the construction of diagnostic analysis models for the inflow and infiltration of local intelligent drainage systems and enrich the case studies of the inflow and infiltration of sanitary sewer systems in coastal cities.
ACKNOWLEDGEMENT
The authors appreciate the financial support from the Key R&D Program of Zhejiang Province (2020C03082).
DATA AVAILABILITY STATEMENT
Data cannot be made publicly available; readers should contact the corresponding author for details.
CONFLICT OF INTEREST
The authors declare there is no conflict.