Abstract
The degradation of a mixture of ibuprofen, naproxen, and diclofenac in various effluents by UVC/H2O2 or UVC/S2O82− was studied to assess the impact of the matrix composition and of the oxidant precursor on process efficiency. Experiments were carried out in a 20-L laboratory pilot (a scaled-down version of a full-scale pilot). In effluents collected during dry weather, the rural constructed wetland effluent allowed faster degradation than the urban conventional WWTP effluent, regardless of the nature of the targets or of the oxidant precursor. This was mainly attributed to a three-times higher chemical oxygen demand in the urban effluent, likely to quench the oxidative species. UV fluences to reach 90% degradation of the three compounds were 3,800 and 5,500 mJ cm−2 in the rural effluent, whereas they were 6,600 and 6,100 mJ cm−2 in the urban effluent with H2O2 and S2O82−, respectively. After a rainfall event, the rural effluent composition was not significantly affected compared to that of the urban effluent that underwent the dilution effect. Therefore, the stability of the rural effluent composition allowed comparable degradation efficiency, whereas the dilution effect led to a significant increase in the degradation rate constants in the urban effluent (up to four times higher).
HIGHLIGHTS
UVC-based process efficiency varies with weather and effluent composition.
Downstream effluent composition seems more consistent in a rural constructed wetland than in an urban WWTP.
UVC-based AOPs are more appropriate to treat effluents with low and consistent organic matter concentration.
allows for faster degradation of NAP and H2O2 for faster degradation of IBU.
ABBREVIATIONS
INTRODUCTION
Pharmaceuticals and their metabolites are ubiquitous in surface and groundwater around the world (Luo et al. 2014). Although their concentrations are mostly under μg/L, adverse effects on aquatic plants and wildlife have been reported, such as alterations in the reproduction or in the development of organisms and changes in behaviour (Patel et al. 2019). The ecotoxicity of pharmaceuticals is generally assessed for isolated substances, for which environmental concentrations are mostly under no observed effect concentrations (Zhou et al. 2019). However, a high number of substances are present in water resources and many studies have shown that the toxicity of pharmaceutical cocktails is very complex, including additive and synergistic effects (Vasquez et al. 2014). While there is still a need to develop knowledge about mixture effects, ways to prevent the spread of pharmaceuticals into aquatic ecosystems must also be explored.
Wastewater treatment plants (WWTPs) are one of the major sources of pharmaceuticals in the environment because they are not designed to treat micropollutants. Although the average removal rate of micropollutants is between 50 and 60%, it varies widely depending on the nature and the concentration of the molecule, the type of treatment and on the environmental conditions (weather, season), especially in nature-based technologies (Li et al. 2014). Various removal efficiencies are depicted in the literature for diclofenac (0–70%), ibuprofen (60–96%) and naproxen (>70%) (Coquery et al. 2010; Dagot 2018). The French project AMPERES concluded that 90% of incoming pharmaceuticals were found at the outlet of 21 WWTPs at concentrations above 100 ng·L−1 (Coquery et al. 2010). As a result, rivers downstream from WWTPs face higher contamination levels than other surface waters (Comber et al. 2018). It is therefore necessary to increase WWTP performance.
As the goal of our research programme is to provide solutions to improve the quality of the effluents in small- and medium-sized WWTPs (hereafter referred to as rural WWTPs) that require low maintenance and cheap treatments, UVC-based advanced oxidation processes (AOPs) are chosen. AOPs are based on the generation of highly oxidative species. They are promising techniques due to their effectiveness against refractory micropollutants and pathogens, their low cost and low maintenance requirements and the easy integration at the outlet of existing WWTPs (Starling et al. 2019). Processes that do not require pH adjustments such as UVC/H2O2 and UVC/ are particularly attractive. UV photolysis of H2O2 and leads to the generation of oxidizing radicals: and , respectively ( = 2.80 V/SHE and = 2.60 V/SHE at neutral pH). As the radicals are not selective, degradation rates of micropollutants can be affected by the presence of organic matter or inorganic ions in wastewaters.
The present study investigates the degradation of model micropollutants by UVC photolysis, UVC/H2O2 and UVC/ on a laboratory pilot which represents a scaled-down and simplified version of a test pilot installed at the outlet of a rural constructed wetland WWTP. The main goals are to assess the impact of photolysis, to compare both oxidant precursors, to study the influence of various WWTP effluents on process efficiency and to gain knowledge towards real scale implementation in WWTP, especially the fluence required.
Three pharmaceuticals are chosen as model micropollutants: ibuprofen (IBU), naproxen (NAP), and diclofenac (DCF). According to Garcia-Rodríguez et al. (2014), IBU is biodegradable, DCF is photolabile and NAP is both. Nonetheless, they are among the most detected pharmaceuticals in domestic wastewaters and have been widely detected in surface waters at concentrations higher than tens of ng L−1 (Patrolecco et al. 2015; Lindholm-Lehto et al. 2016; Madikizela & Chimuka 2017). Their degradation by UVC-based AOPs has already been investigated in the literature at concentrations from 0.1 to 10 μM (Kwon et al. 2015; Gao et al. 2017; Fu et al. 2019) at a laboratory scale on small volumes (around 50 mL) and degradation pathways were suggested (Fu et al. 2019). However, to the best of our knowledge, no comparative study of UVC/H2O2 and UVC/ was carried out on a mixture of these three pharmaceuticals at a pilot scale on real effluents.
MATERIALS AND METHODS
Chemicals and reagents
Ibuprofen sodium salt (98.5%), diclofenac sodium salt (98.5%) and naproxen (98.5%) were purchased from Sigma–Aldrich, as well as sodium persulphate (Na2S2O8) (>98%). Acetonitrile and methanol were supplied by VWR Chemicals (HPLC grade). Ultrapure water was obtained from a milli-Q® system. Formic acid was purchased from Chimie-plus Laboratories. Hydrogen peroxide (H2O2) (30% in water) was supplied by ITW reagents.
Persulphate solutions (1 M) as well as IBU and DCF stock solutions (10 mM) were prepared in milli-Q® water. NAP stock solution (5 mM) was prepared in acetonitrile.
Irradiation experiments
UV pilot unit
The UV fluence was calculated with the UVCalc®2A software which considers the geometry of the reactor, the effluent transmittance and the lamp characteristics (Bolton Photosciences Inc., Canada).
Aqueous matrices composition
Local drinking water was used as a simple matrix to perform first irradiation experiments. It was collected directly from the tap (city of Villeurbanne, France). Then, experiments were performed on spiked WWTP effluents collected in two WWTPs based on different processes with different treatment capacities. The effluents referred to as ‘urban wastewaters’ were collected in the morning at the outlet of a large-scale conventional WWTP (activated sludge process) (300,000 population equivalent, Villeurbanne, France). The effluents referred as ‘rural wastewaters’ were collected at the outlet of a small-scale WWTP equipped by a vertical flow constructed wetland preceded by a trickling filter (1,100 population equivalent, Vercia, France). Samples were collected during dry and wet weathers in 30-L plastic containers and used within 24 h after collection. The rural wet weather effluent was collected after 28 mm of rainfall over 24 h, whereas the urban one was collected after 24 h of severe rain leading to 106 mm of rainfall. The main physico-chemical parameters of the matrices are depicted in Table 1.
. | Local drinking water . | Urban – dry weather . | Urban – wet weather . | Rural – dry weather . | Rural – wet weather . |
---|---|---|---|---|---|
pH | 7.7 | 7.9 | 7.4 | 7.1 | 7.2 |
UV254nm transmittance | 98% | 55% | 64% | 65% | 60% |
Conductivity (μS cm−1) | 395 | 964 | 250 | 994 | 911 |
COD (mgO2 L−1) | <5 | 46.4 | 31.8 | 14.5 | 14.6 |
(mg L−1) | 220 | 231 | 63 | 203 | 189 |
Cl− (mg L−1) | 10 | 66 | 50 | 183 | 151 |
(mg L−1) | 5.1 | 22.6 | 7.1 | 19.0 | 25.2 |
(mg L−1) | – | 1.33 | 0.30 | 0.06 | 0.07 |
. | Local drinking water . | Urban – dry weather . | Urban – wet weather . | Rural – dry weather . | Rural – wet weather . |
---|---|---|---|---|---|
pH | 7.7 | 7.9 | 7.4 | 7.1 | 7.2 |
UV254nm transmittance | 98% | 55% | 64% | 65% | 60% |
Conductivity (μS cm−1) | 395 | 964 | 250 | 994 | 911 |
COD (mgO2 L−1) | <5 | 46.4 | 31.8 | 14.5 | 14.6 |
(mg L−1) | 220 | 231 | 63 | 203 | 189 |
Cl− (mg L−1) | 10 | 66 | 50 | 183 | 151 |
(mg L−1) | 5.1 | 22.6 | 7.1 | 19.0 | 25.2 |
(mg L−1) | – | 1.33 | 0.30 | 0.06 | 0.07 |
Experimental procedure
The total volume introduced into the system was 20.0 ± 0.5 L and the recirculation flow was fixed at 20.0 ± 0.5 L min−1. In these conditions, the hydraulic retention time in the reactor per cycle was 3.5 s. Experiments were carried out at 22 ± 2°C. The UVC lamp was preheated for 10 min and turned off during solution preparation.
Matrices were first spiked with IBU, NAP, and DCF at 5 μM each. This concentration is higher than environmental concentrations, but it was chosen because it does not require pre-concentration before ultra high-performance liquid chromatography (UHPLC) analysis. Then, an appropriate volume of oxidant precursor was added to reach 0.5 mM and the light was turned on at the start of the experiment. Oxidant precursor concentration was set according to preliminary experiments (Cédat et al. 2016).
Five millilitres of the solutions were withdrawn at fixed time intervals for UHPLC quantification of the pharmaceuticals. Volume variations in the system were under 0.1% during irradiation experiments.
A Shimadzu 2450 UV–visible spectrophotometer was used to measure the aqueous matrix transmittances at 254 nm, the UV–visible spectra of pharmaceuticals and oxidant precursors (Supplementary material, Figures S1 and S2, respectively).
Determination of the photolysis constants of H2O2 and
Experiments were performed in the experimental apparatus in the same conditions as described above. The only changes are related to the concentrations of H2O2 or which became 5 mM and with the addition of 0.5% of MeOH (100 mL) before the experiment in order to quench and and avoid their reactions with the oxidant precursors. Five millilitres of solutions were withdrawn at fixed time intervals for the quantification of H2O2 and by UV–visible spectrophotometry (Shimadzu, 2450) at 240 and 215 nm, respectively.
Micropollutants analysis
Samples were filtered through 0.45 μm PVDF filters (Millex HV) before analysis. IBU, NAP and DCF analyses were performed in duplicate using an UHPLC ultimate 3000+ (Thermo Fischer) system equipped with a X-Bridge BEH column (75 × 4.6 mm × 2.5 μm) and coupled to a diode array detector (detection wavelengths: λIBU = λNAP = 226 nm, λDCF = 281 nm).
The mobile phase was a mixture of acetonitrile and milli-Q water (60/40) both acidified with 0.1% formic acid and the flow rate was 1.5 mL min−1. The column temperature was fixed at 40 °C and the injection volume was 40 μL. Limits of detection were 0.12, 0.10 and 0.09 μM for IBU, NAP and DCF, respectively, and limits of quantification were calculated as 3.3 × LOD.
Data processing
In this study, UV fluence (mJ cm−2) was used as a reference unit for degradation rate constants. According to Bolton & Stefan (2002), UV fluence is defined as the total radiant power incident from all directions onto an infinitesimally small sphere of cross-sectional area dA, divided by dA. It depends on the configuration of the system and on the absorbance of the matrix which causes a decrease in the number of photons available for photolysing the targets.
Under UVC photolysis, IBU, NAP and DCF degradation kinetics followed first order rates. They were fitted by the following equation: , where C0 and C are, respectively, the initial concentration and the concentration at UV fluence F of the compound of interest and is its first order degradation rate constant (cm2 mJ−1).
depends on two main physical properties of the compound of interest: the molar absorption coefficient (Ɛ, L mol−1 cm−1) and the photolysis quantum yield (Φ) at the studied wavelength. Ɛ determines the ability of the compound to absorb photons and therefore quantifies the photons available for photolysis. Φ is the number of photolysed molecules divided by the number of absorbed photons (Hokanson et al. 2016).
Therefore, in the presence of H2O2 or , the pollutant degradation kinetics include both their photolysis and their oxidation by or . According to Sharpless & Linden (2003), these degradation kinetics are governed by the following pseudo-first order equation: , where C0 and C are, respectively, the initial concentration and the concentration at UV fluence F of the compound of interest, is its photolysis first order rate constant and is the pseudo-first order rate constant for radical-based oxidation. This constant depends on the steady-state concentration of the radical and on the second order reaction rate between the radical and the compound of interest (Shu et al. 2016). is the overall pseudo-first order rate constant.
The error bars associated with the degradation constants equal to 3σ, derived from the scattering of the experimental data around the fit curves (intra-series variability).
RESULTS AND DISCUSSION
IBU, NAP, and DCF degradation in drinking water
UVC photolysis
IBU, NAP, and DCF photolysis follow first order rate under UV254nm radiation. Table 2 depicts their photolysis rate constants in drinking water (5 μM each). DCF is around 17 times higher than NAP and 50 times higher than IBU. This is attributed to the photosensitivity of the compounds which is mainly based on their molar absorption coefficient (Ɛ) and their quantum yield (Φ). As seen in Table 2, ƐNAP and ƐDCF are of the same order of magnitude and are much higher than ƐIBU. As a consequence, their photolysis is faster than that of IBU. However, ΦNAP is around three times lower than ΦDCF which could explain the slower degradation of NAP compared to DCF.
. | IBU . | NAP . | DCF . |
---|---|---|---|
(cm2 mJ−1) | (1.15 ± 0.15) × 10−4 | (3.34 ± 0.09) × 10−4 | (5.65 ± 0.31) × 10−3 |
Φ254nm (mol Einstein−1) | 0.086–0.192a | 0.036b | 0.094b |
Ɛ254nm (L mol−1 cm−1) | 320 | 4,400 | 5,520 |
. | IBU . | NAP . | DCF . |
---|---|---|---|
(cm2 mJ−1) | (1.15 ± 0.15) × 10−4 | (3.34 ± 0.09) × 10−4 | (5.65 ± 0.31) × 10−3 |
Φ254nm (mol Einstein−1) | 0.086–0.192a | 0.036b | 0.094b |
Ɛ254nm (L mol−1 cm−1) | 320 | 4,400 | 5,520 |
Ɛ254nm was determined in this work. aLuo et al. (2018); bPacker et al. (2003).
In order to reach more than 90% degradation, DCF and NAP require around 400 and 8,000 mJ cm−2, respectively. However, IBU is only degraded by 64% at 9,600 mJ cm−2. Based on these results, the use of UVC radiation seems appropriate for the degradation of DCF which is photosensitive. On the other hand, it would be irrelevant and energy inefficient for the removal of NAP and IBU. In the literature, Kim et al. (2009) had drawn similar conclusions and reported that UVC radiation only allowed complete removal of DCF traces in secondary WWTP effluent under 923 mJ cm−2, whereas NAP required 2,768 mJ cm−2 to reach 90% degradation. Zupanc et al. (2013) have also shown that it is not appropriate for the degradation of IBU.
Influence of oxidant precursors
Regarding DCF, a very photosensitive molecule, the addition of oxidant precursors has a moderated impact on its removal: degradation rate constants are multiplied by 1.2 and 1.6 with H2O2 and , respectively, which means that UV fluences can be divided by 1.2 and 1.6 to reach complete degradation in the same conditions, compared to photolysis only. Indeed, (5.65 × 10−3 cm2 mJ−1) is 4.6 and 1.6 times higher than with (1.24 × 10−3 cm2 mJ−1) and (3.63 × 10−3 cm2 mJ−1), respectively, indicating that photolysis is prevailing. This was also observed by Packer et al. (2003) in a UVC/H2O2 system.
Regarding IBU and NAP, which are less photosensitive than DCF, the use of oxidant precursors significantly increases their degradation rates. They allow the multiplication of by almost 11 compared to photolysis only, regardless of the nature of the oxidant precursor. is multiplied by approximately 6 in the presence of H2O2, whereas it is multiplied by 20 in the presence of . As a consequence, coupling oxidant precursors to UVC radiation can significantly reduce the energy consumption of the process. For example, the complete degradation of IBU (implying the complete removal of DCF and NAP) requires around 4,000 and 2,500 mJ cm−2 in the presence of H2O2 and , respectively, whereas it is degraded by less than 35% at 4,000 mJ cm−2 under UVC only.
Influence of aqueous matrix on the degradation rates of IBU, NAP, and DCF
The same UVC/H2O2 and UVC/ experiments were then carried out in effluents from a rural constructed wetland (rural effluent) and an urban conventional WWTP (urban effluent) spiked with the mixture of pharmaceuticals. Effluent compositions are reported in Table 1.
Comparison between drinking water and WWTP effluents
It was previously reported in the literature that the decrease in advanced oxidation performances in secondary effluents is attributed to the quenching of and by various species, causing a reduction in the number of available radicals. Indeed, it was observed in the present study that DCF is mainly photolysed, whereas IBU and NAP are mainly oxidized and, from drinking water to secondary effluents, only decreased by 11–31%, whereas and were more impacted. As a consequence, it can also be concluded that the quenching of the radicals played a significant role in the decrease in performance.
The quenching depends on the nature and concentration of the quenching species, of the targeted micropollutants and of the oxidants. In the present study, both WWTP effluents have higher chemical oxygen demands (COD) and Cl− concentrations than drinking water, whereas concentrations are comparable (Table 1). The urban effluent induces a stronger decline in the degradation rates than the rural effluent and its COD is three times higher (46.4 mg L−1) than that of the rural effluent (14.5 mg L−1), whereas its Cl− concentration is almost three times higher in the rural effluent and concentrations are similar. Therefore, the organic matter seems to be the main quencher of and .
In the literature, Gabet et al. (2021) and Olmez-Hanci et al. (2015) concluded that the organic matter is the main quencher for and in WWTP effluents. Other authors also observed the influence of inorganic anions such as Cl− (Sharma et al. 2015) or (Fu et al. 2019). However, they seem to have a minor impact on process efficiency at the concentrations of secondary effluents.
Regarding UV fluences to reach 90% degradation of IBU (implying complete degradation of NAP and DCF), it increased from 2,100 mJ cm−2 in drinking water to 6,600 and 3,800 mJ cm−2 in the urban and the rural effluents, respectively, in the presence of H2O2 and from 2,100 mJ cm−2 to 6,100 and 5,500 mJ cm−2 in the urban and the rural effluents, respectively, with .
Impact of the weather on process performances
Previous experiments on WWTP effluents collected during dry weather were repeated on effluents collected during wet weather in order to gain knowledge about the potential variations in the effluent composition and their impact on treatment performances.
As seen in Table 1, the concentrations in COD and anions of the urban effluent decreased from dry to wet weather. This is attributed to the dilution of domestic effluents by stormwater leaks received, particularly after a strong rainfall (106 mm in 24 h), and leads to an increase in the UV254nm transmittance by 9%. On the contrary, the composition of the rural effluent showed minor variations (Table 1) from dry to wet weather. Only a 5% transmittance decrease was noticed, which is the average of the fluctuations observed during this work and in previous work (Cédat 2016) on the effluent of this rural WWTP. Therefore, there seems to be good stability of the effluent composition over time and good resilience of the rural system.
This difference in behaviour between the effluents of the two WWTPs could be attributed to the difference in the treatment process, influent composition and WWTP capacity. As a consequence, the effluent composition stability of the rural WWTP seems to enable consistent and efficient removal of the micropollutants by both processes regardless of weather conditions, whereas fluctuating results were obtained with the urban effluent. However, the rural wet weather effluent was collected after a normal rain event, unlike the urban effluent that was collected after heavy rain, likely to result in greater impacts on the effluent composition.
Elements of choice for an oxidant precursor
Efficiency
In the present study, the efficiency of the UVC/H2O2 and UVC/ processes was determined on a mixture of IBU, NAP, and DCF at 5 μM each. In these conditions, allowed 3–6 times faster degradation of NAP than H2O2. Then, both oxidant precursors allowed degradation rates of the same order of magnitude for DCF and for IBU. DCF was degraded faster in the presence of than in the presence of H2O2, however, was only 1.1–1.4 times higher. Regarding IBU, H2O2 allowed a faster degradation of IBU in the rural effluent (×1.4 ± 0.1), whereas it was faster in the presence of in the urban effluent (×1.1). As a consequence, the faster photolysis of under UVC radiation does not seem favourable for the degradation of all the micropollutants, which also mainly depends on the reactivity between the species. In order to determine the most efficient oxidant precursors for implementation at the outlet of a WWTP, a wider range of compounds would have to be studied. However, oxidant precursor choice also has to involve other criteria such as process cost and implementation.
Process cost
Compared to H2O2, the use of for compounds such as NAP and DCF that are more easily degraded by sulphate radicals would allow a decrease in the electrical cost of the process. The economic gain corresponds to the ratio between the UV fluence required with to that required with H2O2. For example, the significant difference regarding NAP would allow to divide the electrical cost by 3–6 times in the presence of compared to H2O2. However, this benefit is only slightly applicable to DCF and not applicable to IBU. As a consequence, the use of does not necessarily imply electricity savings compared to the use of H2O2.
Moreover, raw materials and labour costs also have to be considered in process cost comparison. For instance, the solid form of requires higher labour, inducing higher cost.
The initial oxidant precursor concentration will also have a significant impact on the cost of the process. In the present study, experiments were performed with a constant initial concentration (0.5 mM), in order to compare both oxidant precursors. It was previously reported in the literature that an increase in the initial concentration of oxidant precursor increases the degradation rate constants to a certain extent and that an excess of radical precursor is required for process efficiency, regardless of the initial concentration (Cédat 2016). However, too much of an increase could also lead to an unnecessary increase in process cost and waste of reagent. Therefore, it seems necessary to perform on-site studies in order to assess the required initial concentration for cost/performance ratio optimization.
Implementation in a WWTP
The economic and technical interests of the implementation of a UVC-based process at the outlet of rural WWTPs were previously shown by Cédat (2016) in a preliminary study on a 1,100 population equivalent constructed wetland. However, experiments were only carried out on a one-off basis and did not include effluent composition or condition variations. The present study allowed to conclude that the effluent composition stability and the lower organic matter load during dry weather of the rural secondary effluent make UVC-based AOPs more appropriate for the removal of micropollutants at the outlet of rural WWTPs compared to urban ones. Moreover, Besnault et al. (2014) compared several processes for the removal of micropollutants and observed that the WWTP size has an impact on treatment cost. They reported that UVC-based processes are economically and technically competitive with other processes such as ozone-based ones in medium-sized WWTPs (>60,000 population equivalent), whereas they are less economically and technically interesting in large WWTPs (>200,000 population equivalent) because of the high number of UVC lamps required, leading to a large footprint and elevated investment costs. As a consequence, it can be concluded that UVC-based processes seem to be more adapted for micropollutant removal to rural and small-sized WWTPs, from an economic and technical perspective.
CONCLUSION
This work is aimed at assessing and comparing the abilities of UVC/H2O2 and UVC/ for the removal of micropollutants in various effluents towards an implementation in domestic WWTPs. It was carried out in a 20-L pilot and IBU, NAP and DCF were used as model micropollutants. Preliminary experiments carried out in a simple matrix indicated that DCF is photolabile enough to be degraded in a UVC process. However, IBU and NAP were seen to require the addition of H2O2 or that strongly enhanced their degradation rates.
Then, the use of WWTP effluents collected during dry weather inhibited degradation rates. This inhibition was stronger in the urban effluent: the required UV fluences to reach more than 90% degradation of all the compounds were 74 and 10% higher in the urban effluent than in the rural one, in the presence of H2O2 and , respectively. This was mainly attributed to the three times higher COD in the urban effluent that was likely to increase and quenching. During wet weather, the stable composition and transmittance of the rural effluent allowed similar degradation rates than the effluent collected during dry weather, whereas strong dilution of the urban effluent, collected after unusual heavy rain, allowed to multiply the degradation rates by 1.3–3.7 compared to the dry weather effluent. As a consequence, this study showed that the effluents of rural WWTP, that are often small and medium-sized WWTPs, seem to allow for higher and more consistent performances of UVC-based AOPs than urban WWTPs. This adds to conclusions previously made in the literature regarding the economic and technical attractivity of these processes for the removal of micropollutants in small- and medium-sized WWTPs.
Finally, despite the faster photolysis of , both H2O2 and were seen to be efficient in degrading the targets and presented various performances depending on the compound. NAP underwent faster degradation in the presence of , which was also the case of DCF but to a lesser extent. However, IBU was degraded faster in the presence of H2O2 in the rural effluents.
Despite the faster photolysis of allowing faster degradation of DCF and NAP, IBU underwent faster degradation in the presence of H2O2 in the rural effluents. Moreover, although faster degradation induces lower electrical cost to reach similar degradation, treatment cost also includes reagent and labour cost. With the aim of choosing the oxidant precursor that provides the best efficiency/cost ratio, further experiments on a wider cocktail of compounds at real concentrations would be required. Finally, the consideration of the disinfection capacities of both processes would also allow complete comparison towards a full-scale implementation.
DECLARATION OF COMPETING INTEREST
All authors declare no conflict of interest.
ACKNOWLEDGEMENTS
The authors wish to acknowledge ‘Région Auvergne-Rhône-Alpes’ for their financial support through the ‘Pack Ambition Recherche’. This work was performed within the framework of the EUR H2O'Lyon (ANR-17-EURE-0018) of Université de Lyon (UdL), within the programme ‘Investissements d'Avenir’ operated by the French National Research Agency (ANR). This work was also supported by the ‘Federation des Recherches en Environnement’ through the CPER ‘Environnement’ founded by the ‘Région Auvergne,’ the French government and FEDER from European community. The authors thank Marie-Joëlle N'Tcho Kokrobie who performed preliminary experiments for this study during her internship in the DEEP laboratory.
DATA AVAILABILITY STATEMENT
All relevant data are included in the paper or its Supplementary Information.
CONFLICT OF INTEREST
The authors declare there is no conflict.