Abstract
Nanofiltration (NF) has been used as the default sulfate removal process in platforms to treat seawater for water flooding. Seawater is generally pretreated by chlorination and cartridge filters to reduce fouling of the membranes; however, this pretreatment is insufficient to provide water quality high enough to maintain the productivity of the NF membranes. In this study, the performances of two different pretreatment routes were evaluated. Microfiltration (MF) was evaluated as a replacement for cartridge filters, and the advanced oxidation process UV/H2O2 was evaluated as an additional stage of pretreatment upstream of the cartridge filters. The permeability of the NF membranes after 12 h of seawater sulfate removal in a bench system was 4.4 L·h−1·m−2·bar−1 when the UV/H2O2 process was adopted as the pretreatment and 2.9 L·h−1·m−2·bar−1 when the MF process was adopted, compared to 1.6 L·h−1·m−2·bar−1 achieved for the pretreatment with the cartridge filter alone. These results indicate that NF membrane fouling was significantly higher when seawater was pretreated only by the cartridge filter in comparison to both proposed pretreatments. An economic analysis showed that both systems are economically viable and can potentially reduce the operational costs of the NF sulfate removal process on platforms.
HIGHLIGHTS
Comprehensive analysis of cartridge filters, microfiltration, and advanced oxidation process UV/H2O2 pretreatments for seawater desalination by nanofiltration, the last which has not been well stated in the literature.
UV/H2O2 impact on reducing seawater fouling in membranes.
Economic analysis showing the impact on operational costs of the pretreatments on the nanofiltration sulfate removal process in offshore platforms.
INTRODUCTION
The formation water in oil reservoirs typically contains alkaline cations, such as calcium, strontium, and barium, which may form highly insoluble and adherent inorganic precipitates when associated with divalent sulfate anions () present in the seawater injected for oil recovery (Bader 2007; Su et al. 2012; Ghasemian et al. 2019). Therefore, sulfate removal prior to injection is essential. However, seawater salinity must be partially maintained to preserve the reservoir clay stability. As such, sulfate removal units (SRU) in production platforms employ nanofiltration (NF) membranes that can remove more than 98% of the sulfate from seawater while allowing partial passage of monovalent ions.
The sulfate removal process is initiated by upstream pretreatment, which typically employs cartridge-type filters to remove suspended solids (Moreira et al. 2018). Subsequently, pretreated water is pumped into the spiral-wound NF modules, which offer several attractive advantages for sulfate removal, such as low-pressure operation, high flow rates, and relatively low investment, maintenance, and operating costs. However, membranes are also subject to fouling and scaling by microorganisms, suspended solids, and inorganic precipitation.
Fouling is a major challenge in membrane processes that affects membrane performance by decreasing permeate flux, which leads to an increase in feed pressure and, consequently, higher energy consumption. Several studies have also reported that fouling may alter the membrane surface characteristics, thereby affecting salt rejection (Xu et al. 2006; Agenson & Urase 2007). Antiscalant agents and biocides can minimize fouling effects; however, their efficiency is limited. The use of chemicals, such as chlorine, for controlling microorganism growth can also be detrimental to NF membranes owing to their low resistance to oxidation. Therefore, periodic chemical cleaning is required to recover the membrane permeate flux, increasing operating costs, and shortening membrane lifetime.
The cleaning frequency is highly dependent on feed quality. Even when properly operated and maintained, conventional cartridge filters do not entirely remove suspended solids and microorganisms, resulting in poor water quality and a high membrane fouling tendency (Jezowska et al. 2009). Cartridge filters have other disadvantages, such as frequent replacement and the high volume and weight of the equipment.
Microfiltration (MF) and ultrafiltration (UF) processes have recently been used as alternatives to conventional pretreatment, providing constant and high-quality feed for the sulfate removal process. Membrane filtration has already replaced conventional cartridge filters in some units, and its performance has been reported to improve significantly (Jezowska et al. 2009; Pedenaud et al. 2012; Alam et al. 2017). However, MF and UF processes are generally insufficient for removing natural organic matter (NOM), because of the NOM molecule size (Monnot et al. 2016; Winter et al. 2016).
NOM is a significant cause of permeate flux decline in processes such as NF and reverse osmosis (RO) for seawater desalination, either by organic deposition or biofouling caused by microorganism growth as a result of dissolved NOM consumption (Song et al. 2004; Simon et al. 2013; Winter et al. 2016). The well-established UV/H2O2 advanced oxidation process could represent an interesting option for NF pretreatment, as it can reduce the NOM content and disinfect seawater. In addition, the UV/H2O2 process is a suitable combination of the NF process owing to its operational simplicity and small-sized systems. This combination was previously used by Song et al. (2004) to successfully decrease fouling in groundwater NF (Song et al. 2004). Moser et al. (2018) also reported mitigation of NF flux decline when an membrane bioreactor (MBR) permeate of petroleum refinery wastewater was pretreated by UV/H2O2 (Moser et al. 2018). However, there are few reports on the UV/H2O2 process used prior to seawater desalination or, in fact, the NF process in general.
The reactive ions present in seawater, such as bromide and chloride, may react with hydroxyl radicals and interfere with the application of UV/H2O2. Nonetheless, according to studies reported by Penru et al. (2012), the UV/H2O2 process can promote disinfection and removal of absorbance at 254 nm, associated with the presence of NOM, without the presence of byproducts (Penru et al. 2012). Hence, given the UV/H2O2 process capability of degrading NOM, it has a great potential to reduce membrane fouling and improve membrane cleanability, resulting in improved permeate fluxes and a lower frequency of chemical cleaning, which would expand the lifetime of NF membranes.
In this study, two pretreatment routes for seawater sulfate removal were investigated. One route consisted of MF modules coupled to the NF module, and the other consisted of conventional filtration using a cartridge filter, followed by the UV/H2O2 process upstream of the NF system. The permeate flux decline and water recovery degree of the NF were evaluated. The effectiveness of antiscalant agent addition and chemical cleaning was also analyzed. An economic evaluation of the proposed pretreatment routes on an industrial scale was conducted to compare the operating and capital costs to the conventional systems.
MATERIAL AND METHODS
Feedwater characterization
NF desalination was evaluated using synthetic seawater solutions prepared using pure water and analytical-grade salts with the concentrations listed in Table 1, and samples were collected from Guanabara Bay. Seawater samples from Guanabara Bay were collected at different periods, approximately 50 m ahead of the beachfront near the main campus of the Federal University of Rio de Janeiro. The samples were characterized by turbidity (Policontrol AP-2000), ionic conductivity (Quimis Q405M), and total organic carbon (TOC; Shimadzu TOC-VCPN). Modified fouling index (MFI) was measured for all samples to evaluate the fouling tendency. MFI was used instead of the conventional silt density index (SDI) because it has been shown in several studies to be a more accurate and reliable method for measuring membrane fouling.
Synthetic seawater composition
Salt . | Concentration (mg·L−1) . | % of the total . |
---|---|---|
NaCl | 23,334 | 57.9 |
Na2SO4 | 4,000 | 9.9 |
MgCl2·6H2O | 10,867 | 26.9 |
CaCl2 | 1,133 | 2.8 |
KCl | 800 | 2.0 |
NaHCO3 | 200 | 0.5 |
Salt . | Concentration (mg·L−1) . | % of the total . |
---|---|---|
NaCl | 23,334 | 57.9 |
Na2SO4 | 4,000 | 9.9 |
MgCl2·6H2O | 10,867 | 26.9 |
CaCl2 | 1,133 | 2.8 |
KCl | 800 | 2.0 |
NaHCO3 | 200 | 0.5 |
Membranes
MF membranes were polyimide hollow fibers with 0.4 μm average pore size (PAM Membranas Ltda). The pore size increases from the internal to the outer surface of the fiber, causing filtration to occur toward the fiber lumen. According to the information from the manufacturer, the fibers have a pure water permeability around 200 L·h−1·m−2·bar−1 and a rejection rate of >99% for suspended solids and microorganisms.
Schematic (a) and photographs (b) of the module housing and pressure vessel of the MF modules in a serial connection.
Schematic (a) and photographs (b) of the module housing and pressure vessel of the MF modules in a serial connection.
Each module was equipped with 252 hollow fibers with a 0.25 m2 filtration area, providing a total 0.5 m2 area per vessel. The pilot system contained two parallel pressure vessels, resulting in a total filtration area of 1 m2. NF membrane was an NF90-2540 (FILMTEC™) commercial module accommodated in a stainless-steel pressure vessel with a 2.6 m2 filtration area. Additionally, a sulfate removal membrane (FILMTEC™ SR90-440i) with a filtration area of 28 cm2 was used in a bench-scale NF system. According to the manufacturer, both NF90-2540 and SR90-440i are TFC membranes with a minimum sulfate rejection of 97 and 99.6%, with permeabilities (2.000 ppm MgSO4 solution) of 8.7 and 8.32 L·h−1·m−2·bar−1, respectively.
The permeate flux decline was monitored until a constant permeability value was achieved for membrane compaction with pure water for all the membranes. The NF and MF membrane integrity was evaluated using 2,000 mg·L−1 MgSO4 solutions or suspended solid rejection, respectively. A starch solution (ca. 1 g·L−1) was used to simulate suspended particulates, and rejection was defined as the ratio between feed water and permeate turbidity.
UV/H2O2 process
Seawater samples were filtered through a cartridge filter and subjected to the UV/H2O2 process. UV/H2O2 treatment was performed in batch mode in a glass reactor coupled with a thermostatic bath, and the temperature was maintained at approximately 25 °C. The UV radiation source was an Hg low-pressure germicidal lamp placed in a quartz sleeve at the center of the reactor. The UV dose was calculated from the exposure time and UV lamp irradiance was measured using a photoradiometer (Delta Ohm HD 2102.2).
Hydrogen peroxide (H2O2) at concentrations of 20, 40, 80, 300 and 500 mg·L−1 were added to the feedwater and recirculation at a 15 L·h−1 flow rate was conducted until more than 97% of the H2O2 added was consumed, to determine both the optimal UV dose and H2O2 concentration for organic matter degradation. Higher H2O2 concentrations were not evaluated because of the economic issues associated with the treatment.
Feed samples were collected every 30 min for residual H2O2 quantification and NOM degradation monitoring. Residual H2O2 was measured using the spectrophotometric method with metavanadate, as described elsewhere (Oliveira et al. 2001). NOM degradation was evaluated indirectly by measuring the absorbance spectrum decay using a Shimadzu UV-1800 spectrophotometer at wavelengths ranging from 230 to 400 nm. Sodium sulfite solution at 20 g·L−1 concentration was added to the samples to inactivate H2O2. This procedure is necessary due to the interference of H2O2 in the absorption spectrum, which has non-negligible absorbance ( = 18.6 L·mol−1cm−1) (Penru et al. 2012). The samples generated at the end of each experiment at different H2O2 concentrations were subjected to MFI analysis to evaluate their impact on the membrane fouling.
Membrane experimental set-up and procedures
Schematic diagram of MF- and NF-integrated pilot systems. MF-1 and MF-2 – MF modules; VS-01,02,03 and 04 – electrically activated valves; NF – nanofiltration module; FI – flow indicators.
Schematic diagram of MF- and NF-integrated pilot systems. MF-1 and MF-2 – MF modules; VS-01,02,03 and 04 – electrically activated valves; NF – nanofiltration module; FI – flow indicators.
In the NF system, water was fed from a tank through a high-pressure pump, maintaining the transmembrane pressure at 20 bar. The operation time was varied from 9 to 18 h, and the feed stream was continuously refrigerated to maintain its temperature at approximately 25 °C. The NF was also evaluated on a bench-scale filtration system in a smaller area with an SR90-440i membrane sheet, which is typically employed in SRUs on an industrial scale. This membrane module was not available on a pilot scale.
The performance of the MF and NF processes was evaluated based on the permeate flux decay and water recovery degree. The MF membranes were cleaned with a 100 mg·L−1 NaClO solution recirculating for 4 h. The NF membranes were cleaned by recirculation using a NaOH solution at pH 10 for 30 min and sequentially with a citric acid solution at pH 3 for 90 min. Membrane transport properties were evaluated before and after cleaning to assess the effectiveness of chemical cleaning in recovering the membrane permeability.
Economic analysis

The depreciation was calculated according to the straight-line depreciation method, which is defined as the ratio of the fixed investment amount to the period established in the calculation. A period of 20 years and a 12% annual interest rate were considered. Membranes, UV lamps, and ballast replacements were not included in the estimation and were determined to be independent of operational costs. An SRU with an NF production capacity of 2,000 m3·h−1 seawater treated for injection was considered as the basis of the calculation, continuously operating for 365 day per year. This flow rate was comparable to that of the conventional system used in platforms.
RESULTS AND DISCUSSION
UV/H2O2
Absorbance spectra of the samples before and after UV/H2O2 experiments (a) and A254 removal after UV/H2O2 application (b).
Absorbance spectra of the samples before and after UV/H2O2 experiments (a) and A254 removal after UV/H2O2 application (b).
The absorbance decay was similar under all conditions in which UV/H2O2 was applied (Figure 3(a)). High degradation was achieved, even at the lowest H2O2 concentration. UV irradiation alone was not efficient at completely degrading NOM, whereas the addition of H2O2 alone did not result in significant oxidation. Most of the other spectra showed absorbances close to 0, indicating substantial degradation of NOM, especially at concentrations of 40 and 500 mg·L−1.
MFI of treated seawater after cartridge filtration and UV/H2O2 treatment for different H2O2 concentrations.
MFI of treated seawater after cartridge filtration and UV/H2O2 treatment for different H2O2 concentrations.
All H2O2 concentrations significantly reduced MFI, indicating that the fouling potential of the samples is closely linked to the NOM concentration. MFI was reduced to 0 at concentrations of 300 and 500 mg·L−1, exhibiting the considerable potential of the UV/H2O2 process to improve the performance of seawater NF. As previously discussed, a low H2O2 concentration (20 mg·L−1) significantly reduced MFI and A254, and considering the economic aspect, it was selected for seawater pretreatment. Thus, the UV/H2O2 process using 20 mg·L−1 H2O2 and 8.55 kJ·m−2 UV dose was then applied to feed the NF processes.
Sample characterization
The collected seawater samples showed turbidity values ranging from 7.5 to 13.1 NTU and ionic conductivity ranging from 31.9 to 42.1 mS·cm−1. MF eliminated the turbidity of the samples. In contrast, samples pretreated with cartridge filters still exhibited turbidity higher than 2 NTU, indicating that suspended solids and microorganisms were not completely removed. A synthetic sample emulating seawater was also prepared, and its conductivity was much higher than that of the collected ones (63.3 mS·cm−1), because of the dilution of the Guanabara Bay salinity by several river inflows.
The MFI was used to assess the fouling potential. However, the water quality of Guanabara Bay was significantly affected by environmental conditions during sampling, which resulted in a large variation in MFI, as indicated in Table 2. MFI was zero after MF and exhibited a significant decrease after UV/H2O2 treatment, which was not achieved by cartridge filter filtration alone.
MFI characterization of samples before and after pretreatment routes application
. | Untreated sample . | Cartridge filter filtrate . | Microfiltration permeate . | Cartridge filter filtrate + UV/H2O2a . |
---|---|---|---|---|
Sample 1 | 16.1 | – | 0 | – |
Sample 2 | 260.2 | – | 0 | – |
Sample 3 | 377.8 | 153.8 | 0 | 10 |
. | Untreated sample . | Cartridge filter filtrate . | Microfiltration permeate . | Cartridge filter filtrate + UV/H2O2a . |
---|---|---|---|---|
Sample 1 | 16.1 | – | 0 | – |
Sample 2 | 260.2 | – | 0 | – |
Sample 3 | 377.8 | 153.8 | 0 | 10 |
aMFI of sample 3 for the dosage of 20 mg·L−1 of H2O2 and 8.55 kJ·m−2 UV.
MF pretreatment
Microfiltration permeate flux decay (a) and water recovery (b) of samples 1 and 2. Backwashing and filtration: 35 s/15 min. Total recirculation of both permeate and concentrate streams.
Microfiltration permeate flux decay (a) and water recovery (b) of samples 1 and 2. Backwashing and filtration: 35 s/15 min. Total recirculation of both permeate and concentrate streams.
The initial permeate flux was ∼ 70 L·h−1·m−2, stabilizing at approximately 25 L·h−1·m−2. The recovery was stable in the 60–70% range in both experiments. It should be mentioned that working with a lower recovery rate can increase the permeate flux and can be used to optimize the design of an industrial unit. The turbidity of the permeate and feed water samples throughout the experiments was measured to evaluate the MF efficiency, and the membrane rejection rate remained above 98% during both processes.
The MF membranes were characterized before and after the experiment. The permeability of the MF membranes in the first characterization was 92.8 L·h−1·m2·bar−1. Sample 1 MF reduced the membrane permeability to 53.2 L·h−1·m2·bar−1 (43% reduction). After chemical cleaning, permeability increased to 101.1 L·h−1·m2·bar−1, indicating that sodium hypochlorite was effective in oxidizing the organic matter that adhered to the membrane surface and consequently recovered the membrane permeate flux.
Similar behavior was observed for membrane characterization after sample 2 MF, as permeability declined from 90.6 to 55.7 L·h−1·m2·bar−1 (38% reduction) after the experiment, and increased to 103.6 L·h−1·m2·bar−1 after cleaning. Membrane rejection rates were measured and remained above 98% in all characterizations, demonstrating that chemical cleaning did not cause immediate damage to the membranes, and incrustations caused by seawater were not irreversible. The permeabilities of the cleaned membranes slightly exceeded those of the first characterization, probably because, although the system was rinsed with pure water prior to use in the seawater experiments, the cleaning procedure probably removed the remaining additives or adsorbed materials present in the prior membrane.
Nanofiltration
Normalized permeate flux to initial during nanofiltration of the synthetic sample (a) and Guanabara Bay water sample 3 (MFI = 377.8 s·L−2) with microfiltration pretreatment (b), both samples with and without antiscalant agent addition.
Normalized permeate flux to initial during nanofiltration of the synthetic sample (a) and Guanabara Bay water sample 3 (MFI = 377.8 s·L−2) with microfiltration pretreatment (b), both samples with and without antiscalant agent addition.
For NF of the synthetic sample, the addition of the antiscalant agent resulted in a higher permeate flux, particularly at the end of filtration. The characterization of the NF membranes with MgSO4 solution showed that the membrane permeability decreased slightly from 6 to 5.7 L·h−1·m2·bar−1 (5% reduction) after the test performed without the addition of an antiscalant. Acid cleaning increased the permeability to 5.9 L·h−1·m2·bar−1. Subsequently, an experiment involving the addition of an antiscalant agent was performed. Membrane permeability decreased from 5.9 to 5.4 L·h−1·m2·bar−1 (an 8% reduction). It was not possible to validate the effectiveness of the antiscalant in synthetic seawater because the reduction in permeability was small. Thus, there were no observable effects on the characterization. Acid cleaning increased the permeability to 5.8 L·h−1·m2·bar−1, demonstrating that the chemical cleanings were efficient in both tests and were able to recover the permeate flux of the NF membranes, although not completely.
Overall, for the NF experiment with real seawater pretreated by MF, it can be observed in Figure 6(b) that the performance was very similar in both experiments. The permeate flux decreased to approximately 60% of its initial value after 14 h of operation. NF performance was significantly more affected than that in the experiment with synthetic seawater. As the synthetic seawater contained only dissolved salts, the higher reduction in the Guanabara Bay water might be associated with the presence of soluble organic matter.
Membrane permeability decreased from 5.8 to 5.3 L·h−1·m2·bar−1 (8% reduction) after the experiment with antiscalant addition and from 5.6 to 4.8 L·h−1·m2·bar−1 (15% reduction) after the experiment without antiscalant. The larger reduction might be associated with the use of the agent in reducing scaling formation. However, the membrane permeability remained similar following alkaline cleaning after the experiment with the antiscalant agent, but it recovered to 5 L·h−1·m2·bar−1 for the experiment without antiscalant. Acid cleaning was more effective, recovering permeability to 5.6 L·h−1·m2·bar−1 for both experiments. The rejection rates were above 97% for all characterizations of the NF membranes on the skid system after both synthetic and collected samples nanofiltrations.
Permeate flux for nanofiltration of Guanabara Bay water pretreated by various routes in the pilot system using the NF90-2540 membrane (a) and in the bench-scale system using the SR90-440i membrane (b).
Permeate flux for nanofiltration of Guanabara Bay water pretreated by various routes in the pilot system using the NF90-2540 membrane (a) and in the bench-scale system using the SR90-440i membrane (b).
It can be noticed that the permeate flux does not significantly decline with operation time for samples pretreated by cartridge filtration and UV/H2O2 for both experiments. On the other hand, when the sample was pretreated by MF or cartridge filtration, an accelerated decline was observed. These results indicate that soluble NOM has a more significant impact on NF membrane performance than suspended solids, as MFI was higher for the UV/H2O2 treated sample, as shown in Table 2.
As the membrane area of the bench system was much smaller than that on the pilot scale, the effects on the membrane performance were more pronounced (Figure 7(b)). However, a practically constant permeate flux was achieved during NF of the UV/H2O2 pretreated sample, whereas a permeate flux reduction was observed for samples pretreated by other routes. Cartridge filtration as a pretreatment was not efficient in retaining the material responsible for NF membrane fouling, thus resulting in the worst pretreated feed performance. MF was more effective than cartridge filtration, but flux decline was still observed during the experiment. The permeabilities of the NF membranes at the end of each experiment in the bench-scale system were 4.4 L·h−1·m2·bar−1 for the UV/H2O2 feed, 2.9 L·h−1·m2·bar−1 for the MF feed, 1.6 L·h−1·m−2·bar−1 for the cartridge filtration feed and 0.55 L·h−1·m−2·bar−1 for the untreated feed samples.
The global membrane saline rejection varied between 19 and 25%, but the sulfate rejection rates remained above 97% for all characterizations of the bench-system NF membranes. As such, no effects on the membrane sulfate rejection were observed for the different treatment routes and membranes, as it remained practically constant in all characterizations.
Economic evaluation
The economic evaluation was based on calculating the CAPEX and OPEX for an SRU, considering the three pretreatment routes studied in the experiments. The main costs associated with SRU implementation and operation are based on the work of Weschenfelder et al. (2016). The costs associated with different membrane lifetimes and the implementation of the different pretreatment routes proposed in this study were calculated in comparison with the costs calculated by Weschenfelder et al. (2016), who considered the pretreatment to be the conventional cartridge filters.
The costs associated with OPEX estimation require membrane replacement costs, which depend on the membrane's lifetime. Polymeric membranes may endure 5–10 years of operation, according to the main suppliers. The membrane lifetime was established as 5 years for MF membranes and 4 years for NF membranes, according to the usual NF membrane replacement period in the Brazilian SRU. A lifetime of 7 years was also considered for the NF membranes to assess the lifetime cost impact on the economic feasibility of the process. Membrane costs were obtained through an estimate from major suppliers, and the results per cubic meter of treated water (US$ m−3) are listed in Table 3.
Membranes investment and replacement costs for SRU units
Membrane . | Lifetime (year) . | Annual replacement cost (US$) . | Unitary cost (US$.m−3) . |
---|---|---|---|
MF | 5 | 457,142 | 0.020 |
NF | 4 | 938,601 | 0.054 |
NF | 7 | 536,343 | 0.031 |
Membrane . | Lifetime (year) . | Annual replacement cost (US$) . | Unitary cost (US$.m−3) . |
---|---|---|---|
MF | 5 | 457,142 | 0.020 |
NF | 4 | 938,601 | 0.054 |
NF | 7 | 536,343 | 0.031 |
Equipment and operational costs for an SRU were based on the work of Weschenfelder et al. (2016). The main components present in SRUs were considered for the CAPEX estimation for all pretreatment routes, and their costs are shown in Table 4. The MF unit, MF membranes, and UV unit costs were obtained from major suppliers. The inclusion of the UV system adds a capital cost to the conventional SRU. On the other hand, MF as a pretreatment eliminates cartridge filters, but still exhibits the highest CAPEX, which is related to membrane investment.
Estimated CAPEX for different feed pretreatments of NF units in SRU systems (values in US$)
. | Cartridge filtration . | Cartridge filtration + UV/H2O2 . | Microfiltration . |
---|---|---|---|
Cartridge filters | 5,085,948.68 | 5,085,948.68 | – |
Nanofiltration skid | 8,024,376.65 | 8,024,376.65 | 8,024,376.65 |
Pumps set | 3,691,397.35 | 3,691,397.35 | 3,691,397.35 |
Cleaning system | 813,165.78 | 813,165.78 | 813,165.78 |
Chemical products injection skid | 630,509.33 | 630,509.33 | 630,509.33 |
Electric panel/instrumentation | 530,795.98 | 530,795.98 | 530,795.98 |
Membranes seta | 3,754,404.23 | 3,754,404.23 | 6,040,118.52 |
Technical assistance | 542,280.00 | 542,280.00 | 542,280.00 |
Deaerator | 4,500,000.00 | 4,500,000.00 | 4,500,000.00 |
MF pretreatment skid | – | – | 5,780,000.00 |
UV system | – | 2,417,078.82 | – |
Total | 27,572,878.00 | 29,989,956.82 | 30,552,643.61 |
. | Cartridge filtration . | Cartridge filtration + UV/H2O2 . | Microfiltration . |
---|---|---|---|
Cartridge filters | 5,085,948.68 | 5,085,948.68 | – |
Nanofiltration skid | 8,024,376.65 | 8,024,376.65 | 8,024,376.65 |
Pumps set | 3,691,397.35 | 3,691,397.35 | 3,691,397.35 |
Cleaning system | 813,165.78 | 813,165.78 | 813,165.78 |
Chemical products injection skid | 630,509.33 | 630,509.33 | 630,509.33 |
Electric panel/instrumentation | 530,795.98 | 530,795.98 | 530,795.98 |
Membranes seta | 3,754,404.23 | 3,754,404.23 | 6,040,118.52 |
Technical assistance | 542,280.00 | 542,280.00 | 542,280.00 |
Deaerator | 4,500,000.00 | 4,500,000.00 | 4,500,000.00 |
MF pretreatment skid | – | – | 5,780,000.00 |
UV system | – | 2,417,078.82 | – |
Total | 27,572,878.00 | 29,989,956.82 | 30,552,643.61 |
aMembrane set cost when MF conducts the feed pretreatment includes both processes, MF and NF.
For the OPEX evaluation, additional calculations were necessary regarding UV energy consumption, hydrogen peroxide costs, and MF membrane regeneration. The electrical power of the UV unit was estimated according to the optimum dose obtained experimentally (8.55 kJ·m−2), resulting in 1.06 × 10−2 kWh·m−3. However, it must be noted that the calculated value refers only to the energy required for the generation of UV radiation with a length of 254 nm. The real energy consumed by the light bulb is higher because, according to the manufacturer, only 30% of the consumed energy is converted to UV radiation. In addition, as the irradiation tends to decrease over time, a factor of 0.7 was adopted, and the final estimated energy consumption was 5.06 × 10−2kWh·m−3. As the established production capacity is 2,000 m3·h−1, a 101 kW UV reactor is required for treating seawater similar to the samples used in the experiments.
According to Weschenfelder et al. (2016), energy generated in maritime units costs approximately 0.008 US$.kWh−1. Lamp and ballast replacement costs account for approximately 45% of the total energy cost (Mahamuni & Adewuyi 2010). The average quotation obtained for a system with these characteristics was US$ 2,417,078.82, as indicated in Table 4. The hydrogen peroxide cost was calculated from the concentration defined in the experimental stage (20 mg·L−1) and the average quotation value obtained from different suppliers. The resulting value added to the chemical product cost was 0.002 US$.m−3. MF membrane cleaning was considered to occur every cycle of 10 days of operation to calculate MF membrane regeneration costs.
As the proposed pretreatment routes are able to reduce membrane fouling, a higher lifetime for NF membranes was also considered in the calculations, which is an expected consequence of the lower regeneration frequency. Therefore, it was considered 4 years for NF membrane lifetime as observed in actual Brazilian SRU and 7 years as mentioned in the literature, when a better pretreatment is applied (Pedenaud et al. 2012). Table 5 presents the total OPEX costs per cubic meter of produced injection water (US$ m−3).
Estimated OPEX for different feed pretreatments of NF units in SRU systems (values in US$ · m−3)
. | Cartridge filtration . | Cartridge filtration + UV/H2O2 (4 years) . | Cartridge filtration + UV/H2O2 (7 years) . | Microfiltration (4 years) . | Microfiltration (7 years) . |
---|---|---|---|---|---|
NF membranes regeneration | 0.0130 | 0.0130 | 0.0130 | 0.0130 | 0.0130 |
MF membranes regeneration | – | – | – | 0.0075 | 0.0075 |
Filter replacement | 0.0270 | 0.0270 | 0.0270 | – | – |
NF membrane replacement | 0.0536 | 0.0536 | 0.0306 | 0.0536 | 0.0536 |
MF membrane replacement | – | – | – | 0.0261 | 0.0261 |
UV lamp/ballast replacement | – | 0.0001 | 0.0001 | – | – |
Maintenance and manpower | 0.0090 | 0.0090 | 0.0090 | 0.0090 | 0.0090 |
Chemical products | 0.0980 | 0.1000 | 0.1000 | 0.0980 | 0.0980 |
Operation energy | 0.0010 | 0.0014 | 0.0014 | 0.0010 | 0.0010 |
Depreciation | 0.0680 | 0.0735 | 0.0735 | 0.0700 | 0.0700 |
Total | 0.2695 | 0.2776 | 0.2546 | 0.2782 | 0.2552 |
. | Cartridge filtration . | Cartridge filtration + UV/H2O2 (4 years) . | Cartridge filtration + UV/H2O2 (7 years) . | Microfiltration (4 years) . | Microfiltration (7 years) . |
---|---|---|---|---|---|
NF membranes regeneration | 0.0130 | 0.0130 | 0.0130 | 0.0130 | 0.0130 |
MF membranes regeneration | – | – | – | 0.0075 | 0.0075 |
Filter replacement | 0.0270 | 0.0270 | 0.0270 | – | – |
NF membrane replacement | 0.0536 | 0.0536 | 0.0306 | 0.0536 | 0.0536 |
MF membrane replacement | – | – | – | 0.0261 | 0.0261 |
UV lamp/ballast replacement | – | 0.0001 | 0.0001 | – | – |
Maintenance and manpower | 0.0090 | 0.0090 | 0.0090 | 0.0090 | 0.0090 |
Chemical products | 0.0980 | 0.1000 | 0.1000 | 0.0980 | 0.0980 |
Operation energy | 0.0010 | 0.0014 | 0.0014 | 0.0010 | 0.0010 |
Depreciation | 0.0680 | 0.0735 | 0.0735 | 0.0700 | 0.0700 |
Total | 0.2695 | 0.2776 | 0.2546 | 0.2782 | 0.2552 |
If the lifetime of the NF membrane does not change, the OPEX cost estimates result in comparable values for all the considered pretreatment routes. The operating costs for MF and cartridge filtration followed by UV/H2O2 treatment were approximately 3% higher than the conventional pretreatment cost. The energy cost of a UV reactor is often a decisive factor in the implementation of commercial units. However, it did not significantly affect the OPEX because of the low cost of energy in offshore units. The higher OPEX for MF can be attributed to membrane replacement.
It is essential to note that, as observed in the experiments, the proposed pretreatments reduced the fouling of the NF membrane and, consequently, the need for membrane cleaning. Thus, a direct impact on the operating costs is expected, reducing the demand for chemicals and increasing the membrane lifetime. For an extended NF membrane lifetime of 7 years, a reduction in OPEX was observed for both proposed pretreatment routes, which demonstrates a significant influence on the feasibility of the sulfate removal process. A reduction of about 6% in OPEX was observed for both proposed pretreatment routes.
Comparison of total costs (RCAPEX and OPEX) of conventional SRU system with the proposed MF pretreatment, considering different scenarios for the reduction in chemicals demand. Lifetime of membranes: NF = 7 years; MF = 5 years.
Comparison of total costs (RCAPEX and OPEX) of conventional SRU system with the proposed MF pretreatment, considering different scenarios for the reduction in chemicals demand. Lifetime of membranes: NF = 7 years; MF = 5 years.
As shown in Figure 8, MF pretreatment exhibits a lower cost in all cases, which was also observed in the UV/H2O2 route. These results suggest that the replacement of conventional pretreatment by MF or adding a UV system is economically feasible when there is a substantial improvement in the NF operation due to a reduction in the membrane fouling tendency, which may be possible according to the experimental results.
CONCLUSIONS
In this work, alternative technologies were proposed for the optimization of pretreatment for the sulfate removal NF process. Two routes were analyzed in comparison to the conventional pretreatment with cartridge filters: the replacement of cartridge filters by MF and the sequential addition of the advanced oxidation process UV/H2O2 to the cartridge filters.
The UV/H2O2 process was optimized for the collected samples, and characterization showed that both the UV/H2O2 and MF processes were effective in reducing the MFI and turbidity of the collected samples. Turbidity reduction was reflected in the NF performance, where higher permeate fluxes were observed compared with conventional pretreatment, both on pilot scale and bench scale. Although MFI was null for MF samples and 10 s·L−2 for the UV/H2O2 treated sample, the UV/H2O2 process resulted in better permeate flux in NF compared to the MF sample, which was most noticeable in the bench-scale experiment.
The addition of 10 mg·L−1 antiscalant was slightly useful in preventing scaling of the NF membranes for the synthetic sample during operation. Due to natural sequential dilutions in Guanabara Bay, the collected samples had lower precipitation potential and osmotic pressure. Thus, the permeate flux decay in NF was mainly attributed to the deposition of soluble organic material. It can be inferred that as higher fluxes were obtained for the UV/H2O2 process, it was effective in the degradation of these materials.
The evaluated chemical cleanings were suitable to partially recover the permeability of the MF and NF modules, whose membranes remained intact after all operations were performed. However, there was a decrease in permeability throughout the NF processes, indicating that cleaning procedures can be optimized to increase recovery after each process. Regarding the effect of the pretreatments on the chemical cleanings, no significant difference was observed in preliminary studies.
The economic evaluation showed that the improvement in pretreatment could significantly reduce the production cost of the injection water. Both technologies proposed were not only economically feasible but also cheaper in scenarios where the membrane replacement time and quantity of chemical products were minimized, owing to the better performance of NF membranes. However, it should be noted that the implementation of the proposed pretreatments significantly increased CAPEX costs. Nevertheless, this increase would be advantageous given the positive effects considered, which were shown when calculating the total costs (considering RCAPEX).
A global analysis of the studied processes allows us to conclude that the proposed pretreatments are valid and viable technologies for implementation in SRU. The UV/H2O2 process proved to be the most effective alternative in both experimental and economic studies, although the TC of the latter was similar for both processes. Experimental studies have shown that the addition of UV/H2O2 could significantly improve NF performance in comparison to MF, which would lead to the minimization of chemical product usage and a higher membrane lifetime, increasing economic savings compared to MF replacement. It should also be noted that the studied samples have characteristics that may differ from those of the collected seawater in the SRU because of marine environmental conditions. The characteristics of seawater at great depths may lead to different performances of the studied processes because of the lower organic matter content reported in the literature, which could approximate the effects of MF and UV/H2O2 on NF membrane performance offshore. Choosing the MF or UV/H2O2 process for a SRU would then depend on the advantages and disadvantages intrinsic to the operation of both processes.
It is important to note that the UV/H2O2 process has been poorly described in the literature for application to seawater desalination and presents great potential for pretreatment in other desalination processes, such as reversal osmosis. Its adoption in low NOM water could lead to a reduction in desalination costs, making implementation feasible in many places where reversal osmosis is still too expensive to be used on an industrial scale.
ACKNOWLEDGEMENTS
The authors would like to acknowledge the financial support of Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq).
DATA AVAILABILITY STATEMENT
All relevant data are included in the paper or its Supplementary Information.
CONFLICT OF INTEREST
The authors declare there is no conflict.