Many oxygen plants have been established specially during COVID-19 period and they are still serving for medical needs. The objective of the present work is to utilize solar and waste thermal energy of medical oxygen plants for water production. Humidification–dehumidification desalination (HDD) has been found suitable for this objective due to low temperature energy need during the process. The layout of an HDD unit has been presented to utilize waste heat, specially when solar energy is not much effective or absent. The system has been configured with a jet impingement solar air heater and a packed bed humidifier. A mathematical model has been developed and validated with the results of experiments. A comparative study of the proposed unit (HDD-O2) and a conventional unit has been performed in terms of yield and gained output ratio (GOR). The optimum flow rates of working fluids found in the range 0.03–0.04 kg/s and the temperature of air and water resulted in a continuous gain in yield. The average yield and GOR of the HDD-O2 unit were found to be 8.5 kg/d and 1.1 that could reach up to 11 kg/d and 1.4, respectively. The HDD-O2 unit provided yield at the cost of 0.04 $/kg with a payback period of 1.73 years. The findings of the present work indicated the suitability of the HDD-O2 plant for water production.

  • Novel arrangement of a desalination unit for using renewable (solar energy).

  • Use of a medical oxygen plant for performance enhancement.

  • Nocturnal yield can be achieved.

  • Significant improvement in yield and gained output ratio.

Ac

area of glass cover (m2)

Ab

area of base plate (m2)

Aj

heat transfer area of jet plate (m2)

Apb

back area of absorber plate (m2)

Cg

specific heat of glass cover (J/kg K)

Ca

specific heat of air (J/kg K)

Dh1

hydraulic diameter of passage below jet plate (m)

Dh2

hydraulic diameter of passage above jet plate (m)

E

annual energy output

e

rib height (m)

h

heat transfer coefficient (W/m2 K)

H

enthalpy (J/kg)

I

solar irradiance (W/m2)

k

thermal conductivity (W/m K)

ma2

mass of air in the passage below absorber (kg)

mg

mass of glass cover (kg)

mj

mass of jet plate (kg)

mp

mass of absorber plate (kg)

Ma

mass flow rate of air (kg/s)

Mfw

mass flow rate of condensate water (kg/s)

Mw

mass flow rate of water (kg/s)

Mmw

mass flow rate of makeup water (kg/s)

Q

heat transfer term

Re

Reynolds number

Ta2

mean temperature of air below jet plate

Ta2

mean temperature of air below absorber plate

Tb

temperature of base plate

Tfw

temperature of condensate water

Tg

temperature of glass cover

Tj

temperature of jet plate

Tmw

temperature of makeup water

Tp

temperature of absorber plate

Ts

surrounding (ambient temperature)

Tsky

temperature of sky

Tw

temperature of water

Ub

bottom loss coefficient

Vw

wind speed (m/s)

w

specific humidity (kg/kg of dry air)

Z1

height of upper channel (m)

α

absorptivity

ε

emissivity

τ

time (s)

τg

transmissivity of glass

ηp

fin effectiveness

average CO2 emission by coal/annum

ϕCO2

annual CO2 mitigation

The importance of a medical oxygen plant in a medical facility is well evident because it provides life-saving oxygen. Many pressure-swing adsorption plants have been established for oxygen production, specially during the COVID-19 period, and those plants are still in operation for fulfilling O2 requirements. These oxygen plants release hot air as waste from a compressor unit during their functioning period. The present work aims to utilize this hot air for potable water production through a humidification–dehumidification process. The simplicity of operation of the humidification–dehumidification desalination (HDD) process always appealed to researchers because of its utilization of low temperature thermal sources. However, in the case of sole solar assistance, effective production can be achieved over limited hours and this duration is not encouraging in moderate or cold climates.

Many configurations of an HDD unit have been developed by integrating low temperature thermal energy sources (Alghassab 2024) for heating process air, water, or both, which in due course, resulted in a higher yield. The augmentation of the humidification and dehumidification process has been proposed by Elminshawy et al. (2016) by utilizing geothermal energy with a solar HDD unit. The integrated unit provided the yield of 104 L/m2 with an average gained output ratio (GOR) up to 1.58. Lawal et al. (2018) used a heat pump to fulfill the need of heating and cooling in the HDD system. The proposed integration with a heat pump resulted in increasing the GOR up to 8.8. Abdullah et al. (2018) proposed a hybrid unit by integrating an HDD process with a wick-type solar still. The effect of the packing material used in the humidifier was studied and a GOR of 5.4 was found. Shojaei et al. (2020) integrated a solar humidifier in an HDD unit which was also configured with a heat pump. The results of these experiments revealed a maximum yield of 1 kg/h and a GOR of 2.36.

Chen et al. (2020) combined an HDD unit with an evaporative air-cooling unit to achieve thermal comfort and yield simultaneously. The proposed combination resulted in 25–125 L/h water and a GOR in the range 1.6–2.5. Qasem et al. (2020) coupled an HDD unit with an absorption refrigeration unit for water production in large quantities. A yield rate of 1.145 L/h was obtained by the proposed configuration with a GOR of 4.54. Jabari et al. (2020) used a solar Stirling engine for power and heat generation. It also ran an HDD system for water production. Sachdev et al. (2020) proposed to couple an HDD unit with a wind tower for simultaneous production of water and thermal comfort. The proposed configuration resulted in 4.5–5 kg yield per day. Kabeel et al. (2022) utilized cold air of an HDD unit for enhancing the performance of the air-conditioner. The proposed unit resulted in a daily yield of 36.49 L and an approximate 60.9% rise in the GOR.

Alrbai et al. (2022) utilized a fogging nozzle for augmenting the humidification process in an HDD unit which resulted in a maximum GOR of 3.4. Santosh et al. (2022) performed experiments on an HDD unit having an energy supply from waste heat at a temperature range of 45–70°C. The maximum yield of 1.398 mL/h was found due to the proposed modifications. Khass et al. (2022) analyzed an HDD system with multi stage humidification and a 151.2 kg/h yield was reported with a GOR of 1.995. Abdel Dayem & Al Zahrani (2022) studied the effect of packing materials in humidification by using a wet cooling tower as the humidifier. The study reported a GOR of 4.3 and a yield of 25 L/d. Welepe et al. (2022) presented a humidifying collector for minimizing the amount of liquid and used it with an HDD unit. The performance of the proposed system was improved by 1.3–32.2 times compared to a conventional system and a yield of 2.923 kg/h was reported.

Shaikh & Ismail (2023) utilized a multistage dehumidifier to reduce the condensing area and cost. The proposed configuration augmented the yield by 6.24% and the output ratio improved by 6.75%. Shamet et al. (2023) utilized heat of a diesel generator which was otherwise released as waste. The analysis of four different configurations of an HDD unit resulted in a maximum GOR of 3.2. Abedi et al. (2023) proposed to use a solar chimney with an HDD system which can provide 600 L of water per day. Easa et al. (2023) examined a high-speed rotary humidifier in an HDD unit. The maximum yield of about 17 kg was obtained at slot bore and spray speed of 0.001 m and 1,200 rpm, respectively. Zarei & Adibi (2023) used rushing packing in the humidifier of the HDD unit and achieved a daily yield of 312 L.

It is clear from the available literature that numerous configurations of HDD units have been developed for the augmentation of yield. In continuation, the present work proposes a layout of the HDD unit for utilizing waste hot air of medical O2 plants. This is a novel approach as (i) waste heat of medical O2 plants has not been utilized in HDD systems so far; (ii) in contrast to conventional solar HDD units, this approach enables the unit for nocturnal yield (or duration when solar energy is ineffective); (iii) the proposed system is configured with a solar air heater having jet plate (SAHJP) with novel ribs and a packed bed humidifier; and (iv) transient behavior of the system was analyzed. Additionally, a moderate climate (Raipur, India) was used for performance evaluation instead of a favorable hot summer climate. For comparative analysis of the proposed unit (HDD-O2) with a conventional (HDD-C) unit, a mathematical model was developed and validated with the available experimental results. Performance parameters such as yield, GOR, humidifier dimensionless parameters, etc. have been evaluated with the help of a computer simulation program for variable inputs. Finally, economic competitiveness of the proposed system was also assessed.

System configuration and description

The functioning of the proposed plant depends on the different situations of availability of hot air from O2 plants, SAHJP, or both. In the first situation, hot air is available from an O2 plant but an air heater is not operational or very much effective. This situation may represent nocturnal hours, morning or evening hours when solar energy is either absent or not effective for air heating. In the absence of hot air from the SAHJP, O2 plants can be scheduled to operate and yield can be produced in an HDD unit by consuming waste hot air of O2 plants. In this manner, additional duration of water production can be achieved at night and late evening/early morning, which is a distinct feature of the proposed unit (named as HDD-O2 for further discussions) over conventional solar HDD units. The schematic outline of the proposed HDD-O2 system for utilizing waste hot air of medical oxygen plants in potable water production is depicted in Figure 1 and a description of the system components are listed in Table 1.
Table 1

Components of the proposed system

ComponentTypeSpecification
Air heater Solar-jet impingement 1.4 × 0.7 m 
Humidifier Packed bed Dimension (80 × 40 × 40 cm) 
Dehumidifier Finned tube Dimension (70 × 40 × 40 cm) 
Storage tank Water tank with tubes for hot air flow Capacity (400 L) 
Fan Electric Size and power (20 cm, 30 W) 
Pump Electric water pump Max flow and power (15 L/min, 40 W) 
ComponentTypeSpecification
Air heater Solar-jet impingement 1.4 × 0.7 m 
Humidifier Packed bed Dimension (80 × 40 × 40 cm) 
Dehumidifier Finned tube Dimension (70 × 40 × 40 cm) 
Storage tank Water tank with tubes for hot air flow Capacity (400 L) 
Fan Electric Size and power (20 cm, 30 W) 
Pump Electric water pump Max flow and power (15 L/min, 40 W) 
Figure 1

Schematic of a desalination unit.

Figure 1

Schematic of a desalination unit.

Close modal

In the proposed system, hot air coming from O2 plants was divided into two routes to incorporate the additional advantage of water heating. In the first route 1-2-3, air follows the states to the humidifier and the dehumidifier for water production, while the second route 6-7 serves to preheat water before supplying to the humidifier. The flow of hot air in route 6-7 depends on the availability of hot air on the basis of the size or number of O2 plants. At the same time, feed water from the storage tank follows the state 4-5 through the humidifier. Valves v1 and v2 regulate the flow of air and v4 ensures the necessary water flow in the humidifier through a pump. The brine at state 5 can be regulated by v8 for recirculating in the process or releasing out. A fan was also provided at the outlet of the dehumidifier for maintaining the proper flow of air in the system. The feed water availability and salinity can be ensured by attachments provided for supplying makeup water and removing the brine.

In the second situation of functioning, hot air is available from the SAHJP and the O2 plant is not operational. This situation may represent the limited diurnal hours of a day when solar thermal energy is effectively available for heating ambient air. The O2 plants can operate in any hours of the day as per the need; however, for water production, it is beneficial if the O2 plants are scheduled to operate during the hours of ineffective solar energy. In this situation, the system follows a conventional process of humidification and dehumidification, and is named as HDD-C for further discussion. Here, ambient air follows the states 8-9-2-3 for yield formation and water from the storage tank follows the state 4-5. In this mode of operation, valve v5 regulates the flow of air coming from the SAHJP and valve v6 will be completely closed to avoid any diversion of air. Valves v1 and v2 will also be closed as the O2 plant is inoperative, and thus, it does not supply hot air. A blower was provided so that ambient air can be supplied to the SAHJP for heating. Similar to HDD-O2, brine recirculation can be regulated in HDD-C by v8.

In the third situation of operation, hot air from both O2 plants and air SAHJP is available; however, hot air from the SAHJP will augment the performance of the proposed unit through humidification–dehumidification when its temperature is higher than the temperature of air coming from the O2 plants. This situation may occur for a very limited number of hours, depending on the location when solar thermal energy is at its peak, and this duration will be minimum in moderate or cold climates. In these hours, air from the SAHJP will enter the humidifier for following the HDD process while hot air from the O2 plants will serve to preheat the feed water in the storage tank. In the remaining hours, when the temperature of air supplied by the O2 plants is higher, valves v5 and v6 will be closed to avoid any mixing with lower temperature air of the SAHJP; otherwise, moisture carrying capacity (as it depends on air temperature) of air will be affected. Thus, the system will again start to operate as in the first situation described previously. As the system mostly follows the first or second situation, except in the few hours of peak solar energy, the performance under the third situation has not been evaluated in this work.

On the basis of the situations explained, the present work compares the performance of HDD-C and HDD-O2. The difference of these two can be summarized as operational hours of the HDD-C unit depends on the availability of effective solar energy, whereas HDD-O2 can operate for additional hours by consuming hot air of the O2 plants in the absence of solar irradiance. The various states followed by process air in HDD-O2 and HDD-C units are illustrated in Figure 2.
Figure 2

States of air in HDD-O2 and HDD-C.

Figure 2

States of air in HDD-O2 and HDD-C.

Close modal

Mathematical modeling

The operation of HDD-O2 and HDD-C was explained with the help of Figure 1 in the previous section. In the present section, energy/mass balance has been considered for HDD-O2/HDD-C components to develop a mathematical model for transient behavior. The schematic of a solar air heater with jet impingement used with the HDD process is illustrated in Figure 3 and Equations (1)–(6) are the corresponding governing equations. The mathematical model suggested by Matheswaran et al. (2018) was followed for the development of these equations; however, the suggested model has been modified as per the design and operation of the present work, i.e. transient behavior and concaved ribs.
Figure 3

Jet impingement solar air heater.

Figure 3

Jet impingement solar air heater.

Close modal
The glass cover receives solar energy and, simultaneously, interacts with the ambient and absorber plates placed at the bottom. Consequently, the energy balance is
(1)
The absorber plate receives solar irradiations transmitting through the glass cover. Additionally, it interacts with air flowing beneath the jet plate. Therefore,
(2)
The air coming through the jet plate impinges on the bottom surface of the absorber plate and, while flowing through the air channel, heat interaction takes place with the absorber and jet plates:
(3)
The jet plate is in contact with air on both sides and, additionally, heat interaction takes place with the absorber plate and the base plate; so, for energy balance,
(4)
The air flowing below the jet plate interacts with the jet plate and the base plate to gain temperature; consequently,
(5)
The base plate is the last component to be considered in the mathematical model of this air heater. The energy balance is
(6)
The hot process air coming either from the O2 plants or the air heater absorbs moisture in the humidifier and, finally, moisture condenses into yield in the dehumidifier. Equations (7) and (8) deal with energy/mass interactions during humidification whereas Equations (9) and (10) correspond to the dehumidifier:
(7)
(8)
The proposed system can operate in two approaches named as HDD-O2 and HDD-C. In the case of HDD-O2, air coming from a medical O2 unit enters the humidifier, whereas for HDD-C, air from the outlet of the air heater enters the humidifier. Therefore, temperature and specific humidity values at the inlet of the humidifier can be taken as per the approach of operation. The mass flow rate of air will be constant because there is no leakage of air from the humidifier:
(9)
(10)
Energy balance equation for the storage tank is
(11)
An important performance parameter for HDD is the GOR, which correlates the energy needed for yield and energy input. This parameter can be calculated as (Thanaiah et al. 2021)
(12)
The mass transfer that took place in the humidifier can be expressed as (Thanaiah et al. 2021)
(13)

Various correlations for calculating the heat transfer terms and thermophysical properties of process air are listed in Table 2. 

Table 2

(a) Equations involved in the mathematical model related to heat transfer and (b) equations of the thermal properties of air (Yamali & Solmus 2006)

S.N.Heat transfer termEquation
(a) 
  
  
  
  
  
  
  
  
  
10   
11   
H.T.CEquation
12   
13   
14   
15   
16   
17   
18   
19   
20   
21   
(b) 
PropertyEquation
Thermal conductivity (k)   
Thermal diffusivity (α  
Kinematic viscosity (υ  
Enthalpy (h2.82 × 10−5T4 − 0.00106T3 + 0.0615T2 + 1.32 T + 10.5  
Specific humidity (w7.7 × 10−7T3 − 1.9510−5T2 + 0.00071 T + 0.02  
S.N.Heat transfer termEquation
(a) 
  
  
  
  
  
  
  
  
  
10   
11   
H.T.CEquation
12   
13   
14   
15   
16   
17   
18   
19   
20   
21   
(b) 
PropertyEquation
Thermal conductivity (k)   
Thermal diffusivity (α  
Kinematic viscosity (υ  
Enthalpy (h2.82 × 10−5T4 − 0.00106T3 + 0.0615T2 + 1.32 T + 10.5  
Specific humidity (w7.7 × 10−7T3 − 1.9510−5T2 + 0.00071 T + 0.02  

The mathematical model presented in the previous section was solved in MATLAB for performance comparison of HDD-O2 and HDD-C. The ordinary differential equations available in the transport model of SAHJP were solved using the fourth-order Runge–Kutta method for air outlet temperature. Thereafter, results were used as input for the calculation of performance parameters with the help of governing equations related to the humidifier, dehumidifier, and storage tank. The ambient conditions involved are represented in Figure 4 and the parameters used for simulations are listed in Table 3.
Table 3

Parameters used for simulation

ParameterValue
Location 21.2514° N, 81.6296° E Raipur (India) 
Collector dimension 1.4 × 0.3 m 
Depth of upper channel 0.03 m 
Depth of lower channel 0.04 m 
Thickness of insulation 0.05 m 
Thermal conductivity of insulation 0.032(W/mK) 
Absorptivity of absorber plate 0.9 
Transmissivity of glass cover 0.9 
Emissivity of glass cover 0.9 
Emissivity of absorber plate 0.9 
Emissivity of jet plate 0.9 
Streamwise pitch ratio 0.043 
Spanwise pitch 0.435 
Jet diameter ratio 0.435 
Rib dimension 0.003 × 0.003 m 
Pitch 0.01 − 0.04 m 
Air mass flow rate 0.025 kg/s 
Water mass flow rate 0.025 kg/s 
Water mass flow rate in dehumidifier 0.03 kg/s 
Mass of absorber plate 4.5 kg 
Mass of base plate 4.5 kg 
Mass of glass 3.5 kg 
Glass emissivity 0.9 
Storage tank 400 L 
Temperature of air from O2 plant 65°C 
ParameterValue
Location 21.2514° N, 81.6296° E Raipur (India) 
Collector dimension 1.4 × 0.3 m 
Depth of upper channel 0.03 m 
Depth of lower channel 0.04 m 
Thickness of insulation 0.05 m 
Thermal conductivity of insulation 0.032(W/mK) 
Absorptivity of absorber plate 0.9 
Transmissivity of glass cover 0.9 
Emissivity of glass cover 0.9 
Emissivity of absorber plate 0.9 
Emissivity of jet plate 0.9 
Streamwise pitch ratio 0.043 
Spanwise pitch 0.435 
Jet diameter ratio 0.435 
Rib dimension 0.003 × 0.003 m 
Pitch 0.01 − 0.04 m 
Air mass flow rate 0.025 kg/s 
Water mass flow rate 0.025 kg/s 
Water mass flow rate in dehumidifier 0.03 kg/s 
Mass of absorber plate 4.5 kg 
Mass of base plate 4.5 kg 
Mass of glass 3.5 kg 
Glass emissivity 0.9 
Storage tank 400 L 
Temperature of air from O2 plant 65°C 
Figure 4

Ambient data used in simulation.

Figure 4

Ambient data used in simulation.

Close modal

Validation of model

First of all, the simulation code developed for performance comparison of HDD-O2 and HDD-C has been validated to ensure the accuracy of results. The experimental results of Moshery et al. (2021) and Thanaiah et al. (2021) are used for validating the mathematical model in terms of thermal efficiency (air heater) and GOR (HDD system). The comparison between experimental and simulated results with identical operating and design parameters are depicted in Figure 5. It is evident from the comparison that mean deviation is below 5%, and thus, good agreement of the results is ensured.
Figure 5

Validation of the present work.

Figure 5

Validation of the present work.

Close modal
Figure 6 shows the hourly variation in air temperature at the outlet of the SAHJP for the considered ambient condition. It is clear that the air temperature before 11 am and after 4 pm is considerably low and, therefore, cannot contribute very much for water production. As discussed earlier, HDD-O2 can play its role by utilizing waste heat of O2 plants for achieving additional yield compared to HDD-C. In performance comparison, the production run of HDD-C is from 11 am to 4 pm, whereas HDD-O2 additionally runs from 8 am to 11 am and 4 pm to 7 pm.
Figure 6

Air outlet temperature of the SAHJP.

Figure 6

Air outlet temperature of the SAHJP.

Close modal
The variation in yield and GOR of HDD-O2 and HDD-C are depicted in Figure 7. Figure 7(a) shows the variation of yield and GOR with the mass flow rate of air at the inlet of the humidifier for both HDD-O2 and HDD-C. It is evident that an increase in the air flow rate in the range of 0.03–0.04 kg/s enables the systems to achieve a higher GOR, whereas with a further rise in the air flow rate, a slight dropping trend in output was observed.
Figure 7

Variation of yield/GOR of HDD-O2 and HDD-c.

Figure 7

Variation of yield/GOR of HDD-O2 and HDD-c.

Close modal

The reason for this can be explained with yield variations, which is the highest in the air flow range of 0.03–0.04 kg/s. An approximate 91% improvement in the GOR of HDD-O2 and 120% improvement in the GOR of HDD-C was found. HDD-O2 resulted in 53.1% higher GOR in comparison to HDD-C when the air flow rate was increased to the 0.03–0.04 kg/s range, and overall, HDD-O2 resulted in about 50.2% higher GOR. The increase in the mass flow rate of air initially allowed to carry higher quantity of moisture which ultimately turns to higher yield. Therefore, the GOR was also found to increase but a further higher rate does not contribute very much in favor of the GOR.

Figure 7(b) illustrates the variation in the GOR and yield of HDD-O2 and HDD-C systems with water temperature fed to the humidifier. It is clear that with an increase in water temperature, the GOR also increased continuously. For the considered temperature range, the GOR of HDD-O2 increased by 20.6% and this gain for HDD-C is 18.2%. At the same time, the GOR of HDD-O2 is about 29% higher than the GOR of HDD-C at 45°C whereas, on average, it is 17% more in the considered temperature range. Due to the dependency of the GOR on yield, this variation is very similar to that of yield. The HDD-O2 system resulted in about 49% higher yield than HDD-C. This behavior is evident as air interacting with water at higher temperatures itself gains temperature, which also increases the moisture carrying capacity of air. The air carrying more moisture can provide a higher yield and, therefore, an improvement in the GOR was achieved.

Figure 7(c) reveals the dependency of yield and GOR with the mass flow rate of feed input to the humidifier. A swift gain in the yield of HDD-O2 and HDD-C can be observed till a mass flow rate of 0.03 kg/s, which is 95 and 83%, respectively. Thereafter, an increase in feed was found to be marginally beneficial in augmenting the yield as only about 5% gain was found for HDD-O2 and HDD-C. On an overall basis, HDD-O2 resulted in about 48% higher yield compared to HDD-C. This increase in yield was also responsible for the thermal energy utilized for water production and, therefore, led to an increase in the GOR in a very similar manner. The increase in GOR for HDD-O2 was about 98% and the same for HDD-C was about 88% over the considered flow rate of 0.01–0.06 kg/s. The observed behavior is related to the amount of moisture available in process air, which increased rapidly with the amount of feed water available up to 0.03 kg/s. Since air at particular temperatures has limited moisture carrying capacity, further available feed cannot contribute very much in increasing moisture, and this is evident after the flow rate of 0.03 kg/s.

The effect of supplying more amounts of cooling water in HDD-C and HDD-O2 for dehumidification is illustrated in Figure 7(d). It is clear that both yield and GOR upsurge with the rate of cooling water. However, this increase is mainly up to a flow rate of 0.035 kg/s as the yield of HDD-O2 increased about 400% up to this flow rate. Thereafter, with further increase in the flow rate up to 0.05 kg/s, only 7% improvement was observed. Due to the dependency of the GOR on yield, it also followed a very similar variation. The GOR of HDD-O2 was found to be about 53% (on average) higher in comparison to that of HDD-C. The results made clear that higher amounts of cooling water augmented the yield and GOR by carrying the heat of condensation. Figure 7(e) depicts the variation of yield and GOR with the temperature of cooling water supplied for condensing water vapor. Both the performance parameters were found to have higher values with lower temperature of water as lower temperature augments the heat transfer associated with condensation. On average, the yield of HDD-O2 was found to be 37% higher over HDD-C for the considered temperature variation between 17 and 25°C and, at the same time, this improvement was 25% for the GOR.

The variation of the dimensionless parameter (kav/Mw) of the humidifier with mass flow ratio and water temperature is shown in Figure 8. The considered humidifier parameter continuously decreased with an increase in the mass flow ratio and this reduction was about 54% as the mass flow ratio increased in the range 1–3. At the same time, the relation between the humidifier parameter and the temperature of feed water is also depicted in Figure 8 where the humidifier parameter was found to increase with temperature. This increase was about 60% when the water temperature varied from 25 to 50°C.
Figure 8

Dimensionless parameter (kav/Mw) of humidifier vs mass flow ratio.

Figure 8

Dimensionless parameter (kav/Mw) of humidifier vs mass flow ratio.

Close modal

Economic analysis

The cost competitiveness of the HDD-O2 unit has been evaluated for three different interest rates with the help of methodology followed by Faizan et al. (2022) and Sun et al. (2022). The summary of analysis is provided in Table 4 which is segmented into three parts. Part (a) deals with the calculation of capital cost by considering the cost of individual components (as per local market), part (b) lists the assumed parameters, and finally, part (c) lists the equations used for analysis. The result of the analysis is given in Figure 9 which reveals that the average cost of water per kg from HDD-O2 is 0.04 $ and the corresponding payback period is 1.73 years.
Table 4

Summary of cost calculations

ComponentCost in Rs (as per local market)
(a) Calculation of total initial cost (CT) 
Humidifier 10,000 
Dehumidifier 15,000 
Air heater 17,000 
Water pump 3,000 
Fan 2,000 
Water tank 9,000 
Other 4,000 
 Total (CT) = 60,000 Rs (720 $) 
(b) Parameters of economic analysis 
Parameters Value 
Plant life (n12 years 
Interest rate (r4, 8, 12% 
Average operating and maintenance cost 15% of CA 
Salvage value 15% of CT 
No. of working days 300 
(c) Equations used in analysis 
Parameters Equation 
Annual cost (CACT×FCR 
Capital recovery factor (FCR 
Annual salvage value (CS 
Annual actual total cost (CAACA+CM+COCS 
Cost of water (CwCAA/AY 
Payback period CT/Total gain 
ComponentCost in Rs (as per local market)
(a) Calculation of total initial cost (CT) 
Humidifier 10,000 
Dehumidifier 15,000 
Air heater 17,000 
Water pump 3,000 
Fan 2,000 
Water tank 9,000 
Other 4,000 
 Total (CT) = 60,000 Rs (720 $) 
(b) Parameters of economic analysis 
Parameters Value 
Plant life (n12 years 
Interest rate (r4, 8, 12% 
Average operating and maintenance cost 15% of CA 
Salvage value 15% of CT 
No. of working days 300 
(c) Equations used in analysis 
Parameters Equation 
Annual cost (CACT×FCR 
Capital recovery factor (FCR 
Annual salvage value (CS 
Annual actual total cost (CAACA+CM+COCS 
Cost of water (CwCAA/AY 
Payback period CT/Total gain 
Figure 9

Cost of water vs interest rate.

Figure 9

Cost of water vs interest rate.

Close modal

Enviro-economic analysis

The HDD-O2 plant also contributes toward environment safety as the thermal energy demand for yield is provided by SAHJP and waste heat of medical O2 plants. Therefore, the corresponding reduction in CO2 emission and enviro-economic cost for HDD-O2 have been assessed by the relation and corresponding values as suggested by Joshi & Tiwari (2018):
(14)
(15)

Considering the recommended values of (average CO2 emission by coal/annum) as 2 kg/kWh and enviro-economic cost (PCO2) as 14.5 $/t, CO2 mitigation from the HDD-O2 unit is 3.2 t/annum, whereas the cost involved is 46.4 $/annum.

Performance comparison

Table 5 compares the performance of the HDD-O2 unit with the existing systems working on HDD and other methods, on the basis of novelty in method, yield, cost of water, and GOR that are measures of energy efficiency. It is clear that yield and GOR of the HDD-O2 unit is very attractive compared to the existing units and a novel approach of the HDD-O2 unit based on waste heat of medical O2 plants and SAHJP is responsible for the same. Although the cost is higher in comparison to some approaches due to additional expenses for the utilization of waste heat, it is still competitive due to the achieved gain in yield and GOR. Overall, Table 5 emphasizes the suitability of HDD-O2 as an enhancement approach for the HDD process.

Table 5

Comparison with the existing systems

ReferenceNovelty in methodYieldGOR/EfficiencyCost
Behnam & Shafii (2016)  Bubble column humidifier, evacuated tube collectors and heat pipes 6.27 kg/d 0.65 0.028 $/L 
Abdullah et al. (2019)  Drum distiller 9.2 kg/d 0.85 0.039 $/L 
Thanaiah et al. (2021)  Artificial and bio-based packing materials 0.73 kg/h 0.65 – 
Soomro et al. (2022)  Hydrophobic packing materials 0.64 kg/h 1.45 – 
Shaikh & Ismail (2023)  Multistage bubble column dehumidification 4.57 kg/d 0.79 0.071 $/L 
Muftah et al. (2023)  Basin-type stepped solar still 6.10 kg/m2 0.52 0.07 $/L 
Tiwari & Kumar (2024)  Double-end open evacuated tube solar air heater 3.12 kg/d/m2 0.31 0.038 $/kg 
Present work Waste heat of O2 plants and SAHJP 11 kg/d 1.4 0.04 $/kg 
ReferenceNovelty in methodYieldGOR/EfficiencyCost
Behnam & Shafii (2016)  Bubble column humidifier, evacuated tube collectors and heat pipes 6.27 kg/d 0.65 0.028 $/L 
Abdullah et al. (2019)  Drum distiller 9.2 kg/d 0.85 0.039 $/L 
Thanaiah et al. (2021)  Artificial and bio-based packing materials 0.73 kg/h 0.65 – 
Soomro et al. (2022)  Hydrophobic packing materials 0.64 kg/h 1.45 – 
Shaikh & Ismail (2023)  Multistage bubble column dehumidification 4.57 kg/d 0.79 0.071 $/L 
Muftah et al. (2023)  Basin-type stepped solar still 6.10 kg/m2 0.52 0.07 $/L 
Tiwari & Kumar (2024)  Double-end open evacuated tube solar air heater 3.12 kg/d/m2 0.31 0.038 $/kg 
Present work Waste heat of O2 plants and SAHJP 11 kg/d 1.4 0.04 $/kg 

The proposed HDD-O2 system has been analyzed in this work in comparison with a conventional HDD-C unit. The performance comparison was performed with the help of mathematical simulation. The results and discussion section elaborated on the gain achieved by the HDD-O2 unit for different operating parameters. The key findings are summarized as follows:

  • Hot air from O2 plants augmented the productivity of the HDD unit.

  • The mass flow rate of air in the range 0.03–0.04 kg/s is the most beneficial with the GOR close to 1.2.

  • The feeding rate of 0.03 kg/s of brackish water provided a daily yield around 8.1 kg/d.

  • The cooling water rate of 0.05 kg/s can raise the yield to around 10 kg/d.

  • A high temperature of feed water and a low temperature of cooling water both resulted in a continuous rise in yield and GOR.

  • On average, HDD-O2 resulted in about 43% higher yield compared to HDD-C.

  • The cost of water from HDD-O2 is 0.04 $ and the payback period is 1.73 years.

  • The annual CO2 mitigation from the HDD-O2 unit is 3.2 t and the enviro-economic cost is 46.4 $/annum.

To further enhance the performance and viability of an HDD-O2 unit, it is recommended that optimization of the system components can be done, modification can be included to improve the condensation-evaporation process, and CFD simulation can serve to study the flow of the working fluid though the system.

All relevant data are included in the paper or its Supplementary Information.

The authors declare there is no conflict.

Abdel Dayem
A. M.
&
Al Zahrani
A.
(
2022
)
Psychometric study and performance investigation of an efficient evaporative solar HDH water desalination system
,
Sustainable Energy Technologies and Assessment
,
52
,
102030
.
doi:10.1016/j.seta.2022.102030
.
Abdullah
A. S.
,
Essa
F. A.
,
Omara
Z. M.
&
Bek
M. A.
(
2018
)
Performance evaluation of a humidification–dehumidification unit integrated with wick solar stills under different operating conditions
,
Desalination
,
441
,
52
61
.
doi:10.1016/j.desal.2018.04.024
.
Abdullah
A. S.
,
Essa
F. A.
,
Omara
Z. M.
,
Rashid
Y.
,
Hadj-Taieb
L.
,
Abdelaziz
G. B.
&
Kabeel
A. E.
(
2019
)
Rotating-drum solar still with enhanced evaporation and condensation techniques: Comprehensive study
,
Energy Conversion and Management
,
199
,
112024
.
doi:10.1016/j.enconman.2019.112024
.
Abedi
M.
,
Tan
X.
,
Klausner
J. F.
&
Bénard
A.
(
2023
)
Solar desalination chimneys: Investigation on the feasibility of integrating solar chimneys with humidification–dehumidification systems
,
Renewable Energy
,
202
,
88
102
.
doi:10.1016/j.renene.2022.11.069
.
Alghassab
M. A.
(
2024
)
A review of hybrid solar desalination systems: Structure and performance
,
Water Science and Technology
,
89
(
5
),
1357
1381
.
doi:10.2166/wst.2024.042
.
Alrbai
M.
,
Enizat
J.
,
Hayajneh
H.
,
Qawasmeh
B.
&
Al-Dahidi
S.
(
2022
)
Energy and exergy analysis of a novel humidification-dehumidification desalination system with fogging technique
,
Desalination
,
522
,
115421
.
doi:10.1016/j.desal.2021.115421
.
Chen
Q.
,
Burhan
M.
,
Shahzad
M. W.
,
Ybyraiymkul
D.
,
Akhtar
F. H.
&
Ng
K. C.
(
2020
)
Simultaneous production of cooling and freshwater by an integrated indirect evaporative cooling and humidification-dehumidification desalination cycle
,
Energy Conversion and Management
,
221
,
113169
.
doi:10.1016/j.enconman.2020.113169
.
Easa
A. S.
,
Mohamed
S. M.
,
Barakat
W. S.
,
Habba
M.
,
Kandel
M. G.
&
Khalaf-Allah
R. A.
(
2023
)
Water production from a solar desalination system utilizing a high-speed rotary humidifier
,
Applied Thermal Engineering
,
224
,
120150
.
doi:10.1016/j.applthermaleng.2023.120150
.
Elminshawy
N. A. S.
,
Siddiqui
F. R.
&
Addas
M. F.
(
2016
)
Development of an active solar humidification-dehumidification (HDH) desalination system integrated with geothermal energy
,
Energy Conversion and Management
,
126
,
608
621
.
doi:10.1016/j.enconman.2016.08.044
.
Faizan
M.
,
Toor
Z.
&
Antar
M. A.
(
2022
)
Optimization of two-stage modified air heated HDH desalination systems
,
Arabian Journal of Science and Engineering
,
47
,
16451
16473
.
doi:10.1007/s13369-022-06846-x
.
Jabari
F.
,
Nazari-Heris
M.
,
Mohammadi-Ivatloo
B.
,
Asadi
S.
&
Abapour
M.
(
2020
)
A solar dish Stirling engine combined humidification-dehumidification desalination cycle for cleaner production of cool, pure water, and power in hot and humid regions
,
Sustainable Energy Technologies and Assessment
,
37
,
100642
.
doi:10.1016/j.seta.2020.100642
.
Khass
T. M.
,
Mohammed
R. H.
,
Qasem
N. A. A.
&
Zubair
S. M.
(
2022
)
Different configurations of humidification-dehumidification desalination systems: Thermal and economic assessment
,
Energy Conversion and Management
,
258
,
115470
.
doi:10.1016/j.enconman.2022.115470
.
Lawal
D.
,
Antar
M.
,
Khalifa
A.
,
Zubair
S.
&
Al-Sulaiman
F.
(
2018
)
Humidification-dehumidification desalination system operated by a heat pump
,
Energy Conversion and Management
,
161
,
128
140
.
doi:10.1016/j.enconman.2018.01.067
.
Matheswaran
M. M.
,
Arjunan
T. V.
&
Somasundaram
D.
(
2018
)
Analytical investigation of solar air heater with jet impingement using energy and exergy analysis
,
Solar Energy
,
161
,
25
37
.
doi:10.1016/j.solener.2017.12.036
.
Moshery
R.
,
Chai
T. Y.
,
Sopian
K.
,
Fudholi
A.
&
Al-Waeli
A. H. A.
(
2021
)
Thermal performance of jet-impingement solar air heater with transverse ribs absorber plate
,
Solar Energy
,
214
,
355
366
.
doi:10.1016/j.solener.2020.11.059
.
Muftah
A. F.
,
Sopian
K.
,
Ibrahim
A.
,
Elbreki
A.
&
Abed
A. M.
(
2023
)
Design and evaluation of a modified basin-type stepped solar-still under Malaysia climate conditions
,
Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
,
45
,
6756
6771
.
doi:10.1080/15567036.2023.2216177
.
Qasem
N. A. A.
,
Zubair
S. M.
,
Abdallah
A. M.
,
Elbassoussi
M. H.
&
Ahmed
M. A.
(
2020
)
Novel and efficient integration of a humidification-dehumidification desalination system with an absorption refrigeration system
,
Applied Energy
,
263
,
114659
.
doi:10.1016/j.apenergy.2020.114659
.
Shamet
O.
,
Lawal
D. U.
,
Al Hariri
A. H.
&
Antar
M.
(
2023
)
Performance of different HDH desalination units powered by diesel engine generator waste heat
,
Process Safety and Environmental Protection
,
179
,
651
666
.
doi:10.1016/j.psep.2023.09.046
.
Shojaei
M.
,
Mortezapour
H.
&
Jafarinaeimi
K.
(
2020
)
Experimental investigation of a heat pump-assisted solar humidification–dehumidification desalination system with a free-flow solar humidifier
,
International Journal of Environmental Science and Technology
,
17
,
2401
2414
.
doi:10.1007/s13762-019-02554-6
.
Soomro
S. H.
,
Santosh
R.
,
Bak
C.
,
Yoo
C.
,
Kim
W.
&
Kim
Y.
(
2022
)
Effect of humidifier characteristics on performance of a small-scale humidification-dehumidification desalination system
,
Applied Thermal Engineering
,
210
,
118400
.
doi:10.1016/j.applthermaleng.2022.118400
.
Thanaiah
K.
,
Gumtapure
V.
&
Tadesse
G. M.
(
2021
)
Experimental analysis on humidification-dehumidification desalination system using different packing materials with baffle plates
,
Thermal Science and Engineering Progress
,
22
,
100831
.
doi:10.1016/j.tsep.2020.100831
.
Welepe
H. J. N.
,
Günerhan
H.
&
Bilir
L.
(
2022
)
Humidifying solar collector for improving the performance of direct solar desalination systems: A theoretical approach
,
Applied Thermal Engineering
,
216
,
119043
.
doi:10.1016/j.applthermaleng.2022.119043
.
Zarei
T.
&
Adibi
P.
(
2023
)
Operational analysis of a humidification–dehumidification desalination in packed bed humidifier and dehumidifier columns with salt- and freshwater recirculation
,
Journal of Brazilian Society of Mechanical Sciences and Engineering
,
45
,
635
.
doi:10.1007/s40430-023-04556-5
.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).